INSTALLATION MANUAL
-
CONTENTS
- Safety Precautions - Installation Diagram - Outline and Dimensions - Installation Of The Indoor Unit - Installation Of The Outdoor Unit - Refrigerant Piping - Electrical Connection - Purging The Refrigerant Piping - Additional Charge - Overall Checking - Standard Operating Condition - Auto Random…
-
INSTALLATION DIAGRAM
-
Indoor Unit (CC series)
-
Outdoor Unit (SLC series)
LIQUID SUCTION SL A B C D E F G H J K L M N 30C/40C/50C/60C 1030 141.5 746.5 P 82 ! Caution hazards. Avoid from being in contact with these places. Sharp edges and coil surfaces are potential locations which may cause injury INSTALLATION OF THE INDOOR UNIT The indoor unit must be installed such that…
-
INSTALLATION OF THE OUTDOOR UNIT
The outdoor unit must be installed such that there is no short circuit of the air discharge air or obstruction to smooth air flow. Respect the installation clearance show on the table. Select the coolest possible place where intake air should not be higher than the outside temperature (maximum…
-
REFRIGERANT PIPING
Do not use contaminated or damaged copper tubing. If any piping, evaporator or condenser had been exposed or had been opened for 15 seconds or more, vacuum the system. Generally, do not remove plastic, rubber plugs and brass nuts from the valves, fittings, tubings and coils until it is ready for…
-
PIPING CONNECTION TO THE UNITS
PIPE SIZE (mm/in) TORQUE (Nm) 6.35 (1/4) 9.53 (3/8) 12.7 (1/2) 15.88 (5/8) 19.05 (3/4) Align the center of the piping and sufficiently tighten the flare nut with fingers. Finally, tighten the flare nut with torque wrench until the wrench clicks. When tightening the flare nut with the torque wrench…
-
(Heat pump units for Heat pump series 10CR~25CR with wire remote control & PCB)
CC 10CR SL 10BR CC 15CR SL 15BR CC 20CR SL 20BR CC 25CR SL 25BR 220V – 240V /1Ph/ 50Hz + ! Recommended fuse Power Supply Cable size Number of conductors A mm2 Interconnection Cable size Number of conductors mm2 1.5 3 1.5 3 2.5 3 2.5 3 1.5 3 1.5 3 2.5 3 2.5 3 IMPORTANT: These values are for…
-
(Heat pump units for Heat pump series 30CR with wire remote control & PCB)
Indoor unit Outdoor unit Voltage range CC 30CR SL 30CR 220V – 240V /1Ph /50Hz + ! Recommended fuse A 25 Power Supply Cable size Number of conductors mm Interconnection Cable size Number of conductors mm2 1.5 7 IMPORTANT: These values are for information only, they should be checked and selected to…
-
COMP N INTERCONNECTION CABLE COMP TERMINAL STRIP INDOOR UNIT TERMINAL STRIP OUTDOOR UNIT L N R S T ! The electrical power must be provided with protection devices (circuit breaker or fuse) with double pole separation system (phase + neutral) with minimum contact gap of 3mm. POWER SUPPLY CABLE N…
-
PURGING THE REFRIGERANT PIPING
Purging the piping and the indoor unit Except the outdoor unit which is pre-charged with refrigerant R22, the indoor unit and the refrigerant connection pipes must be air purged because the air that contain moisture remaining in the refrigerant cycle may cause malfunction to the compressor. The…
-
The refrigerant is pre-charged in the outdoor unit. If the
piping length is less than 5m, additional charge after vacuuming is not necessary. When the piping length is more than 5m, use the table below. Additional charge operation This operation must be done by using gas cylinder and a precise weighing machine obligatorily. The additional charge is top up…
-
OVERALL CHECKING
Ensure the following, in particular:1) The unit is mounted solidly and rigid in position. 2) Piping and connections are leak proof after charging. 3) Proper wiring has been done. Drainage check-pour some water into left side of drain pan (drainage are in right side of unit) • Test run 1) Conduct a…
-
• Disconnect from the main power supply before servicing the air conditioner unit. DO NOT pull out the power cord when the power is ON. This may cause serious electrical shocks which may result in fire hazards. AUTO RANDOM RE-START FUNCTION If there is a power cut when the unit is operating, it will…
-
! Caution
Do not operate any heating apparatus too close to the air conditioner unit. This may cause the plastic panel to melt or deform as a result of the excessive heat. TROUBLE SHOOTING When any malfunction of the air conditioner unit is noted, immediately switch off the power supply to the unit. Check the…