Инструкция на Тепловые насосы для бассейна Hayward серии HeatPro - HP20654T, HP20654BT, HP20854BT, HP20854T, HP21104T. Руководство по эксплуатации.
Смотрите также: Руководство по установке →
Загружаем документ…
Текст инструкции
-
HP20854BT and HP21104T OWNERS OPERATION & PARTS MANUAL Attention Installer: Give this manual to the homeowner. Important Information to keep for Service Model # Serial # Install Date SAVE THIS OWNERS MANUAL The Hayward HeatPro Heat Pump is listed by ETL as complying with the latest edition of the…
-
Page 2 of 22
HP13023772 Rev: E HEATPRO HEAT PUMP IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS IN THIS OWNER’S MANUAL AND ON EQUIPMENT. Before servicing this electrical equipment, turn power supply OFF. KEEP ALL LABELS IN GOOD CONDITION AND REPLACE IF MISSING OR DAMAGED. WARNING – To reduce risk…
-
Page 3 of 22
o o o o o HP13023772 Rev: E HEATPRO HEAT PUMP Dual suction fittings shall not be located on seating areas or on the backrest for such seating areas. The maximum system flow rate shall not exceed the flow rating of any listed (per current revision of ASME/ANSI A112.19.8) suction outlet cover…
-
Page 4 of 22
HP13023772 Rev: E HEATPRO HEAT PUMP 6. If the pool/spa is used for therapy, it should be done with the advice of a physician. Always stir pool/spa water before entering the pool/spa to mix in any hot surface layer of water that might exceed healthful temperature limits and cause injury. Do not…
-
Page 5 of 22
HP13023772 Rev: E HEATPRO HEAT PUMP The following table lists the minutes it will take to heat a pool 1°F, based on gallons. This is an approximation only. Model Pool Size in Gallons 200 500 1000 1500 2000 5000 HP20654T & HP20654BT 80°F 70°F 60°F 50°F HP20854T & HP20854BT 80°F 70°F 60°F HP21104T…
-
Page 6 of 22
HP13023772 Rev: E HEATPRO HEAT PUMP How a Heat Pump Works TXV C A E HOT WATER OUT HEAT FROM AIR D COLD WATER IN B COMPRESSOR AIR COIL (EVAPORATOR) WATER HEAT EXCHANGER (CONDENSER) The heat pump takes heat from the environment and uses it to heat the pool water. During heat pump operation, high…
-
Page 7 of 22
HEATPRO HEAT PUMP HP13023772 Rev: E High / Low Refrigerant Pressure Switches • The high-pressure switch senses the refrigerant pressure in the sealed refrigeration system and turns the heat pump off if the operating pressure exceeds the acceptable range. The heat pump will automatically reset the…
-
Page 8 of 22
HP13023772 Rev: E HEATPRO HEAT PUMP Clearance A minimum of 2 feet (.6 m) of clearance from walls, shrubbery, equipment, etc. is required around the entire heat pump. This allows for ample air intake. A minimum of 6 feet (2 m) of clearance above the heat pump is required to prevent re-circulation of…
-
Page 9 of 22
HP13023772 Rev: E HEATPRO HEAT PUMP NOTICE Make sure there are no sprinkler heads near the heat pump that will spray on or into the unit. Sprinkler damage is not covered under the warranty agreement. Make sure that sprinklers are placed at a sufficient distance away, so that normal wind will not…
-
Page 10 of 22
HEATPRO HEAT PUMP HP13023772 Rev: E Operating the HeatPro Heat Pump NOTICE- Do not use this heat pump if any part has been flooded or submerged in water. Immediately call a qualified technician to inspect and replace any damaged part of the heat pump. Control System components must be replaced if…
-
Page 11 of 22
HEATPRO HEAT PUMP HP13023772 Rev: E Becoming Familiar with HeatPro Heat Pump Controls Up Arrow Button Display Window Down Arrow Button Spa Button (Optional) Pool Button Run Light Heat Pump Control Panel Display Window (All Models) When power is supplied to the unit, the display will either show…
-
Page 12 of 22
HEATPRO HEAT PUMP HP13023772 Rev: E Control Operation Dual Thermostat (Models HP20654T, HP20654BT, HP20854T, HP20854BT & HP21104T) On/Off: This control does not have a true on/off feature. The unit uses standby mode instead. Scrolling dots in the display indicate standby. Standby mode serves two…
-
Page 13 of 22
HEATPRO HEAT PUMP HP13023772 Rev: E Changing Temperature Display (All Models): The control will display temperatures in either degrees Fahrenheit or Celsius. To change the temperature display, place the heat pump in “Stand-By” mode so that the scrolling dots appear on the screen. Press and hold both…
-
Page 14 of 22
HEATPRO HEAT PUMP HP13023772 Rev: E Owner Inspection Hayward recommends that you inspect your heat pump on a seasonal basis and especially after significant weather events. Refer to the sections of this Manual: “Clearance”, “Roof Run-Off”, “Drainage and Condensation” for proper inspection.…
-
Page 15 of 22
HEATPRO HEAT PUMP HP13023772 Rev: E Some heat pump owners desire their pool to be heated during the winter months. This is possible when daytime temperatures are above 50°F [10°C] for most of Hayward’s heat pumps. If temperatures fall below freezing, be certain to keep the pool filter pump operating…
-
Page 16 of 22
HEATPRO HEAT PUMP HP13023772 Rev: E 6. Ensure that the pump and skimmer baskets are clean; also ensure that the pool filter is clean and supplying proper water flow to the heat pump. 7. If the heat pump is not able to maintain the desired temperature, depending on the time of the year, it may be…
-
Page 17 of 22
HP13023772 Rev: E HEATPRO HEAT PUMP Troubleshooting Circuit Breakers: If it is suspected that a circuit breaker is tripped, turn the breaker to the “Off” position and then back to the “On” position. NOTICE: Service to be conducted ONLY by an EPA Certified Service Technician. General Troubleshooting…
-
Page 18 of 22
HP13023772 Rev: E HEATPRO HEAT PUMP Display Diagnostic Codes - Troubleshooting Guide for Hayward HeatPro Heat Pump Display Problem No power to heat pump (Blank) Unit will not turn on Possible Cause Tripped circuit breaker/ no power supply Faulty electrical component 5-minute delay PS Water Pressure…
-
Page 19 of 22
HEATPRO HEAT PUMP HP13023772 Rev: E Heat Pump Replacement Parts Diagram CONTROL BOX FOR: HP2654T, HP20654BT, HP2854T, HP20854BT & HP21104T USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Pomona, CA Clemmons, NC Nashville, TN Tel: 908.351.5400 www.haywardpool.com
-
Page 20 of 22
HP13023772 Rev: E HEATPRO HEAT PUMP Heat Pump Replacement Parts List Item Part description HP20654T HP20654BT HP20854T HP20854BT HP21104T 1 FAN TOP HPX01023502 HPX01024821 HPX01023502 HPX01024821 HPX01023502 2 SIDE PANEL HPX01023503 HPX01024822 HPX01023503 HPX01024822 HPX01023503 3 CONTROL BOX COVER…
-
Page 21 of 22
HEATPRO HEAT PUMP HP13023772 Rev: E HAYWARD® HEAT PUMP POOL HEATER LIMITED WARRANTY The HAYWARD heat pump pool heater is warranted to be free of defects in materials and workmanship for a period of two (2) years for parts and (1) one year for labor. In the state of Florida, warranty labor is covered…
-
Page 22 of 22
HEATPRO HEAT PUMP HP13023772 Rev: E ▼DETACH HERE: Fill out bottom portion completely and mail within 10 days of purchase/installation. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Pomona, CA Clemmons, NC Nashville, TN Tel: 908.351.5400 www.haywardpool.com
Схемы, таблицы и рисунки — в просмотре документа выше. Клик по номеру страницы открывает её в просмотре.