HP13023770 Rev: F
Models: HP20654T, HP20654BT, HP20854T, HP20854BT and HP21104T INSTALLATION GUIDE Important Information to keep for Service Model # Serial # Install Date SAVE THIS INSTALLATION GUIDE The Hayward HeatPro Heat Pump is listed by ETL as complying with the latest edition of the “UL Standard for Safety for…
-
Page 2 of 20
HEATPRO HEAT PUMP HP13023770 Rev: F IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS IN THIS INSTALLATION GUIDE AND ON EQUIPMENT. Before installing or servicing this electrical equipment, turn power supply OFF. KEEP ALL LABELS IN GOOD CONDITION AND REPLACE IF MISSING OR DAMAGED.…
-
Page 3 of 20
o o o o o HEATPRO HEAT PUMP HP13023770 Rev: F Dual suction fittings shall not be located on seating areas or on the backrest for such seating areas. The maximum system flow rate shall not exceed the flow rating of any listed (per current revision of ASME/ANSI A112.19.8) suction outlet cover…
-
Page 4 of 20
HEATPRO HEAT PUMP HP13023770 Rev: F 6. If the pool/spa is used for therapy, it should be done with the advice of a physician. Always stir pool/spa water before entering the pool/spa to mix in any hot surface layer of water that might exceed healthful temperature limits and cause injury. Do not…
-
Page 5 of 20
HEATPRO HEAT PUMP HP13023770 Rev: F Hayward HeatPro Heat Pump Dimensions MODELS: HP20654T, HP20654BT, HP20854T, HP20854BT and HP21104T Hayward HeatPro Heat Pump Specifications USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Pomona, CA Clemmons, NC Nashville, TN Tel: 908.351.5400 www.haywardpool.com
-
Page 6 of 20
HEATPRO HEAT PUMP HP13023770 Rev: F Installation Specifications Receipt Inspection of Heat Pump Unit The carton bears specific warnings stating “DO NOT DROP OR TAILGATE”, as well as arrows indicating the correct vertical positioning. THE HEAT PUMP MUST NOT BE TIPPED OR TRANSPORTED ON ITS SIDE AS…
-
Page 7 of 20
HEATPRO HEAT PUMP HP13023770 Rev: F Placement / Clearances All criteria given in the following sections reflect minimum clearances. However, each installation must also be evaluated, taking into account the prevailing local conditions such as proximity and height of walls and public access areas.…
-
Page 8 of 20
HEATPRO HEAT PUMP HP13023770 Rev: F Drainage and Condensation Condensation will be produced by the evaporator coil when the unit is running and drain at a steady rate, usually three to five gallons per hour, depending upon ambient air temperature and humidity. The more humid the conditions, the more…
-
Page 9 of 20
HEATPRO HEAT PUMP HP13023770 Rev: F Anchoring Anchor Installation Follow all relevant Local, State and National requirements regarding wind load anchoring. When anchoring is required to secure the heat pump to concrete pad, use the specified hardware shown in the diagrams below. USE ONLY HAYWARD…
-
Page 10 of 20
HEATPRO HEAT PUMP HP13023770 Rev: F Plumbing Specifications and Layout The figure below illustrates the standard plumbing layout with a single heat pump unit. FILTER POOL HEATER MANUAL ISOLATION VALVES CHECK VALVE CHEMICAL FEEDER POOL PUMP FROM POOL OR SPA CHEMICAL LOOP MANUAL BYPASS VALVE TO POOL…
-
Page 11 of 20
HEATPRO HEAT PUMP HP13023770 Rev: F NOTICE - When the piping installation is complete, operate the pool filter pump with the heat pump off. Check the entire piping system for leaks. Observe the filter water pressure gauge for abnormalities or obstructions in the filtering system. Failure to follow…
-
Page 12 of 20
HEATPRO HEAT PUMP HP13023770 Rev: F Unions Two detachable union connectors, (2 union nuts and 2 gaskets) included with the heat pump, must be installed on the heat pump water inlet and outlet to facilitate servicing and winterizing the unit. (See figure below). Gasket Union Connector Union Nut…
-
Page 13 of 20
HEATPRO HEAT PUMP HP13023770 Rev: F NOTICE - If the heat pump runs for more than a couple of minutes without the filter pump running, the unit can become overheated and damaged. After adjusting the pressure, turn off pool pump to ensure the heat pump does not run. It is possible for water to flow…
-
Page 14 of 20
HEATPRO HEAT PUMP HP13023770 Rev: F Installation in Combination with Solar or Gas Heaters If you are installing a heat pump in combination with any other type of heating device, please call the HAYWARD service department at (908) 355-7995. We will advise you of installation practices that will help…
-
Page 15 of 20
HEATPRO HEAT PUMP HP13023770 Rev: F WARNING - This heat pump contains wiring that carries high voltage. Contact with these wires could result in personal injury or death to pool or spa users, installers, or others due to electrical shock, and may also cause damage to property. Always disconnect…
-
Page 16 of 20
HEATPRO HEAT PUMP HP13023770 Rev: F equipment must be connected to this bonding grid. A bonding lug is provided on the rear of the base pan of the heat pump to facilitate bonding. Wiring Diagrams Refer to the following wiring diagrams for electrical connections. This wiring diagram is for use with…
-
Page 17 of 20
HEATPRO HEAT PUMP HP13023770 Rev: F Connecting to Remote Systems HAYWARD heat pumps are compatible, in the heating mode only, with one or more of the remote systems in the pool and spa industry today. Thoroughly read all installation instructions of the remote system before connecting this unit. The…
-
Page 18 of 20
HEATPRO HEAT PUMP HP13023770 Rev: F Start-Up Procedures 1. Apply power to the pool heater by plugging in the non-fused disconnect block or moving the circuit breaker to the “ON” position. 2. Place the pool heater thermostat in the “Standby” mode by ensuring the light above the “POOL” button (and…
-
Page 19 of 20
HEATPRO HEAT PUMP HP13023770 Rev: F General Troubleshooting Guide for Hayward HeatPro Heat Pump Problem Unit is not operating. Heat pump is running but is not heating, “Run” light does not come on. Heat pump runs continually Possible Cause No power to unit Breaker is tripped Thermostat not turned up…
-
Page 20 of 20
HEATPRO HEAT PUMP HP13023770 Rev: F Display Diagnostic Codes -Troubleshooting Guide for Hayward HeatPro Heat Pump Display (blank) Problem Possible Cause Solution No power to heat pump Tripped circuit breaker/ no power supply Check breaker and ensure that the unit is properly installed. Faulty…
-
Page 21 of 20
HEATPRO HEAT PUMP HP13023770 Rev: F USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Pomona, CA Clemmons, NC Nashville, TN Tel: 908.351.5400 www.haywardpool.com