Service
-
2.1 Parts Illustration 41 2.2 Parts List 42 Index i Drawings & Flow Charts iii ii Table of Contents
-
1. Safety Cautions
1.1 Cautions and Warnings Read the following warnings and cautions BEFORE operating the system and use it correctly. This manual classifies the precautions to the user into the following two categories. Each mention important cautions on safety, so be sure to keep them. WARNING Failure to follow a…
-
Caution
Do not use the equipment in a place filled with oily smoke such as a kitchen or in a place filled with combustible gas, corrosive gas or metal dust. Otherwise fire and equipment malfunction can result. Do not use in humid places or places which might be wet, such as bathrooms. Contact with water can…
-
Caution
Do not place water containers such as fish bowls and flower vases near the equipment. Water can cause electrical shock and equipment malfunction when it enters the equipment. Do not wipe with benzene or thinner, or spray with insecticide. Such substances can cause cracking, electric shock and/or…
-
Using Icons List
Icon Type of Information Note Description A “note” provides information that is not indispensable, but may nevertheless be valuable to the reader, such as tips and tricks. Note: Caution A “caution” is used when there is danger that the reader, through incorrect manipulation, may damage equipment…
-
1. Operating Manual
OPERATING MANUAL MODEL MC401VE MC40 2 1VE PHOTOCA TALYTIC Operation Manual
-
Thank you for purchasing this Daikin Air Cleaner
This instruction manual explains how to use the equipment and important safety precautions. READ IT CAREFULLY BEFORE using the equipment. Keep this manual handy for future reference. Your warranty is included in the product package. Check your warranty has been properly filled out by the place of…
-
Names and Functions of Parts 1.2 Indicator Lamps and their Functions 4 SiE74-202 Operation Manual
-
1 Photocatalytic deodorizing, Eliminates odors 3 times
bacteria removal and faster than earlier models. antiviral effect 2 Plasma dust collection Clears air of cigarette smoke and pollen. 3 7-year filter roll Longer-lasting and less troublesome. 4 Silent running Just 34.5 dB in “High” mode. 16 dB in “Silent” mode. 5 Energy-saving inverter Great…
-
Tips for appropriate use
To remove house dust, set the unit near to the floor. To remove cigarette smoke, install the unit high on a wall. Installing the air cleaner as shown below improves air circulation in the room. While heating or cooling the room, air can be cleaned and temperature fluctuation minimized. Set operating…
-
Operating Manual CAUTION Read this section carefully BEFORE using the equipment. Do not use the power cable if it is damaged. Using a damaged power cable is extremely hazardous; if the power cord becomes damaged, you must obtain a replacement from the manufacturer or from a properly-authorized…
-
When used in conjunction with a humidifier, keep
mist from being directly drawn into the unit. Mists can lead to electric shock and/or equipment damage. Do not use in the place of kitchen fans or cooker hood fans. Adverse conditions of use can shorten service-life of the prefilter and ion filter, as well as lead to equipment damage. Prevent…
-
Operating Manual Names and Functions of The Indicator Lamps A “Ionizer needs cleaning” lamp Flashes when the ionizer is dirty. See page 14. B Time to cut filter lamp/Reset button This lamp lights up when it is time to change the ion filter. After with ball-point pen, etc. See page 16. fitting a new…
-
SiE74-202 Setup How to Fit the Ion Filter Roll. CAUTION Always fit the prefilter and ion filter roll before use. Use without filters can damage the equipment. 1. Remove the front panel. Hold the front panel by the sides, pull up and out. Front panel or Front panel MC40 1VE 1 2 PHOTOCTAIYTIC P HO MC4…
-
Operating Manual Installation Selecting an Installation Site. The unit can be place on a flat surface such as a desk. <To place on a desk> Min. 100 cm Min. 10cm MC4 01 1 VE P HOTOCTAIYTIC AIR CLEANER 2 4 Min. 10cm Select a wall, shelf or floor that is sturdy enough to support the unit. The unit…
-
1.10 How to Operate the Unit
Before attempting to use the unit, plug the power cable into a single phase 220 – 240 V/220 V (50/60 Hz) socket. Note For the first 2 seconds after the front panel has been reattached or the power cable plugged in, the unit does not respond to remote controller commands - not even the buttons in .…
-
1.11 How to Clean the Prefilter
When to clean Once every 2 weeks or so. 1. Stop the unit and remove the power cable from its socket. 2. Remove the front panel. Hold the front panel by the sides, pull up and out. Front panel or Front panel MC40 1VE 1 2 PHOTOCTAIYTIC PH MC4 AIR 4 01 CLEANER 1 VE OTO AIR CLEANER CTAI YTI C 2 4 3.…
-
1.13 How to Clean the lonizer
If (see page 4) on the front panel begins to flash, clean the ionizer. 1. Stop the unit and remove the power cable from its socket. 2. Remove the front panel. See step 2 on page 13. 3. Remove the ion filter (roll) case. Hold the ion filter (roll) case by the left and right side handles, and lift…
-
6. Remove the ion filter roll
7. Clean the ionizer. • How to clean the case Remove dirt with a vacuum cleaner or by other means, and then rinse the filter under plain water. Ion filter (roll) case For stubborn dirt, wipe or soak in a neutral household detergent. Use a soft cloth or soft bristle brush. Thoroughly rinse off all…
-
8. Reattach the ionizer to the ion filter (roll) case
1 Insert the pegs on the ionizer into the holes on the ion filter (roll) case. 2 Snap the ionizer onto the case. 2 1 Ion filter (roll) case Ionizing wires Hook Ionizer seen from backside Ionizing wires Note • Check the ionizing wires are not loose or broken. 1.14 How to Change the Ion Filter (Roll)…
-
4. Cut the ion filter
A Pull the ion filter off the 2 pegs on the case. pegs (×2) B Unroll the ion filter until the slits in the leading edge of the next filter sheet can be fitted over the pegs on the case. pegs (×2) C Tear the old filter sheet off at the perforated line. 5. Attach the ion filter (roll) case to the…
-
SiE74-202 Operation Manual
-
1. Troubleshooting
1.1 Equipment does not Operate Method of Malfunction Detection Malfunction Decision Conditions Equipment cannot be operated by remote controller or switch on main unit. Supposed Causes Faulty door switch (safety switch assembly) Blown fuse Faulty printed circuit board (control PCB assembly, display…
-
From previous page
Check 5-volt power supply (between X6A (1) and (2)). Is voltage higher than 5.0 VDC? NO Replace control PCB A1P (control PCB assembly). YES Check connector connection of A2P display PCB assembly. Is connection normal? NO Correct connector connection. YES Replace display PCB (Display PCB assembly)…
-
SiE74-202 Indicator does not Change from "Dirty" to "Clean" Method of Malfunction Detection Malfunction Decision Conditions Air contamination indicator does not change to "clean" even when equipment is operated in ventilated room for a whole day. Supposed Causes Faulty harness Faulty sensor…
-
Remote Controller Fails to Operate Equipment
Method of Malfunction Detection Malfunction Decision Conditions Switches on main unit work properly, but remote controller fails to operate equipment. Supposed Causes Noise generated by fluorescent lamps Faulty remote controller Faulty PCB Troubleshooting Caution Be sure to turn off power switch…
-
Photocatalytic Operation does not Activate
Method of Malfunction Detection Malfunction Decision Conditions Photocatalytic operation does not activate during equipment operation (lamp does not light). Supposed Causes Faulty lamp Faulty transformer Faulty PCB Troubleshooting Caution Be sure to turn off power switch before connect or disconnect…
-
Power supply voltage check
Troubleshooting 25
-
SiE74-202 Troubleshooting
-
1.1 Removal of External Accessories Procedure Step 1 External appearance 2 28 Warning Be sure to turn off all power supplies before disassembling work Procedure Points Remove front panel. Removal Procedure
-
3 Disengage hooks located
at four corners of the filter to remove prefilter located at rear side of the front panel. 4 Hold the ion filter (roll) case by the left and right side handles, and lift upward and out. 5 Main components Removal Procedure Removal Procedure of MC401VE Procedure Points 29
-
SiE74-202 Removal of Ionizing Wire Procedure Step 1 Press the hook and lift the ionizing wire slightly upwards and pull it to remove. 2 Install the ionizing wire as shown on the right. 3 Remove the ionizing wire. Warning Be sure to turn off all power supplies before disassembling work Procedure…
-
Removal of Electrical Parts (Inverter Lamp)
Procedure Step 1 Turn main body over, then remove back panel. 2 Removal Procedure of MC401VE Warning Be sure to turn off all power supplies before disassembling work Procedure Points Disconnect CN12 connector located at bottom left of main body rear side. Removal Procedure 31
-
3 Remove the
photocatalyst filter retainer by unscrewing two screws. 4 32 SiE74-202 Procedure Points Remove the photocatalyst filter. Removal Procedure
-
5 Remove inverter lamps
Removal Procedure Removal Procedure of MC401VE Procedure Points 33
-
Removal of PCB
Procedure Step 1 Unscrew two screws at the both side of the main body. Warning Be sure to turn off all power supplies before disassembling work Procedure Points Disengage 6 hooks. 2 34 Disengage the 6 hooks to remove display PCB. Removal Procedure
-
Removal Procedure of MC401VE Procedure Points Remove the control PCB by unscrewing three screws. Removal Procedure 35
-
SiE74-202 Removal of Fan Motor Procedure Step 1 Remove back panel to remove fan securing nut. Warning Be sure to turn off all power supplies before disassembling work Procedure Points Caution When reassembling fan, match the D-cut direction of fan and shaft. 2 Disconnect connector. 3 Remove three…
-
Removal Procedure of MC401VE Removal of Safety Switch Procedure Step 1 To remove safety switch, push it out from back side. Removal Procedure Warning Be sure to turn off all power supplies before disassembling work Procedure Points 37
-
SiE74-202 Removal Procedure
-
Wiring Diagram
SiE74-202 1. Wiring Diagram MC401VE 3D027638 1.1 40 Reference Data
-
Parts List
2. Parts List 2.1 Parts Illustration MC401VE Reference Data 41
-
таблицы и схемы — в просмотре
-
Daikin Europe N.V. is approved by LRQA for its Quality
Management System in accordance with the ISO9001 standard. ISO9001 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product. Daikin units comply with the European regulations that guarantee the safety of the product. ISO14001 assures an…
Схемы, таблицы и рисунки — в просмотре документа выше. Клик по номеру страницы открывает её в просмотре.