AIR HANDLING SYSTEMS
RhossOfficialChannel Rhoss RHOSS S.P.A. Via Oltre Ferrovia, 32 - 33033 Codroipo (UD) - Italy tel. +39 0432 911611 - rhoss@rhoss.it www.rhoss.it - www.rhoss.com Italy Sales Departments: Codroipo (UD) 33033 Via Oltre Ferrovia, 32 tel. +39 0432 911611 Nova Milanese (MB) 20834 Via Venezia, 2 - p. 2 tel.…
-
A global organisation with companies and a presence worldwide NIBE Group is a global organisation that contributes to a smaller carbon footprint and better utilisation of energy. In its three business areas – Climate Solutions, Element and Stoves – we develop, manufacture and market a wide range of…
-
Be the change
you want to see in the world
-
Our focus on world-class solutions in sustainable
energy contributes to the global goal to reduce emissions of greenhouse gases into the atmosphere. Our entire value chain, from vision to end customers, must be based on the principles of sustainability in our business principles. We are responsible not only for the financial results of our…
-
Change
your perspective! Solutions that look to the future.
-
PAGE 17
Air handling terminal units 850÷16500 m³/h Terminal unit UTNA Platinum 6,4÷70 kW Web code: UTAP1 PAGE 20 Heat recovery unit UTNR-A Platinum COMFORT Counterflow heat recovery Air flow rate: 400-4.700 m³/h Web code: UTNR3 PAGE 26 Rotative heat recovery Air flow rate: 310÷4,250 m³/h Web code: UTHE3 PAGE…
-
PAGE 45
Modular air handling units 800÷41000 m3/h CTA ADV Next Air Air flow rate: 800÷41,000 m³/h Web code: NA001 PAGE 46 CTA ADV - Custom PAGE 67 Customised air handling units 850÷104970 m³/h PROFESSIONAL Air flow rate: 850÷104,970 m³/h Web code: CTCT PAGE 68 Heat recovery unit FLUXBLOCK Air flow rate…
-
Air’Suite filters
® Living LLivi Li Liv iivvvin ng iin ng n a clean environment is a c concept once on c pt closely linked clos cl osel os se sel se elly ely ly lillink inked ed to to breathing brea br eath thin ing g “clean “c cle lean an aair”. irir””. ItIt has has been been established air,r, i.e. esta es tabl ta…
-
RETURN
EXHAUST SILENCER SUPPLY OUTDOOR AIR SILENCER Example of Air’Suite application contamination from the indoor environment c contamination from the outdoor environment c The term biocidal filtration refers to the combination of granular filtration (classical) and deactivating the biological load…
-
CTA ADV
Custom Hygienic The range of ADV Custom Hygienic air handling units is designed according to high engineering standards and is ideal for applications where cleanliness and hygiene requirements are mandatory. The units have been awarded the Hygiene compliance certificate for Air Handling Units by TUV…
-
peratin theatres
th atre Operating In order for these “critical” ritical” settings ett to work at their th r fullll potential, ential, all sys systems must m st operate pe e at top efficiency i and d be optimised. This concerns concer s nott only the work team or the hospital or laboratory labo ato y equipment, e…
-
The perfect combination
of industrial precision and artisanal love ADV Next Air range air handling units are the perfect balance between industrial precision and craftsmanship, between love, care of the product and the ability to meet market demands, between innovation and tradition. In fact, the particular type of…
-
RHOSS: the
conscious choice for an ecological future EFFICIENCY, TECHNOLOGY and ECOLOGY: the three key words for a sustainable future. Rhoss has always been careful to create comfort, and invests and researches new solutions to be applied to equipment dedicated to the HVAC world: efficiency and technology are…
-
The following table indicates some examples of refrigerant
gases and related GWP. Refrigerant GWP ( UNI EN 378-1 2017) R407C 1774 R134a 1450 R410A 2088 R513A 631 R1233zd 4,5 R1234ze 7 R32/R452 B 675 R454 B 466 Rhoss has long started this process of harmonisation with the new “green” gases, testing and experimenting with new solutions, without precluding any…
-
Our certifications,
in 360 degrees ISO 9001:2015 Certification RHOSS Spa provides quality goods designed for environmental comfort, making them available and accessible thanks to the advanced technological and organisational level achieved, and, above all, to the committed, reliable and dedicated approach that RHOSS…
-
EUROVENT certification for CHILLERS, HEAT
PUMPS (CCP-HP) AND FAN-COILS (FCU) Rhoss participates in the Eurovent certification programmes for chillers, heat pumps and fan coils. The performance of Rhoss products is therefore guaranteed by tests performed by an accredited third party certification company. AHU N° 09.07.361 Range ADV EUROVENT…
-
Terminal unit - UTNA Platinum 013÷120
-
COMFORT
Air handling terminal units 850÷16500 m³/h
-
Readily available
Rhoss solutions UpToDate is the ideal tool for selecting the Rhoss product range and verify the technical data of each model. The integrated calculation engine requires the verification of feasibility of the proposed solution, the selection and technical dimensioning of the catalogue models. A…
-
Web code: UTAP1 Terminal unit UTNA Platinum 013÷120 Cooling capacity: 6.4÷70 kW - Heating capacity: 4.9÷78 kW • Brushless EC fan IE5 efficiency • ISO Coarse Filter 55% (G4) Airsuite Biocide • ePM1 filter 50% (F7) Modular ductable air handling terminal units. Construction features • Terminal air…
-
UTNAP MODEL BA 2R/BAV 2R kW 4,9 8,4 11,7 16,8 25,1 32,8 39,1 BA/BAV 4R kW 6,4 11,1 14,6 21,3 31,9 45,2 53,6 BA/BAV 4R kW 7,6 13,6 18,4 26,5 39,7 52,3 64,4 BA/BAV 6R kW 8,1 14,9 20,2 27,5 41,2 56,8 68,9 BA/BAV 6R kW 9,1 16,6 22,8 32,2 48,3 62,1 78,2 Heater power 230V-1ph-50Hz kW 3 - - - - - - BE…
-
Terminal unit UTNA Platinum 013÷120 Cooling capacity: 6.4÷70 kW - Heating capacity: 4.9÷78 kW Full Controls • KRFCS - Electrical panel complete with: DDC programmable microprocessor regulator. BMS interfacing Integrated as standard with Modbus RTU protocol, main disconnecting switch, relay to…
-
Heat recovery unit - UTNR-A Platinum 040÷500
Heat recovery unit - UTNR-HE Platinum 040÷400 Heat recovery unit - UTNR-HP 035÷450 Heat recovery unit - VMC-E 025÷130
-
COMFORT
Compact heat recovery units 100÷5300 m3/h
-
Web code: UTNR3 Heat recovery unit UTNR-A Platinum 040÷500 Air flow rate: 400-4.700 m³/h • Horizontal or Vertical Version Fresh air terminal unit with counterflow opposing flow static heat recovery. • Very high efficiency heat recovery Eurovent Certificate Construction features • Multi-speed or…
-
Factory fitted accessories • BER - PRE-POST - Pre-heating electrical resistance (no frost function) installed inside, complete with filament-type safety thermostats and control relays to contain pressure drops. For each size you may choose between 2 available power outputs • BA - Internal hot water…
-
Heat recovery unit UTNR-A Platinum 040÷500 UTNR-A PLATINUM MODEL Type of Unit 3200 3800 4700 Non-residential- Bidirectional Outdoor air filters F7 Return air filters M5 Bypass Motorisable side bypass damper TECHNICAL SPECIFICATIONS Nominal air flow rate m³/h 400 750 1000 1500 2050 STANDARD FANS ❶…
-
Mod. 40-500 HORIZONTAL ORIENTATION TYPE 01 Mod. 40-500 HORIZONTAL ORIENTATION TYPE 02 Electrical panel and filter inspection side BCR/BER (Accessories) BCR/BER (Accessories) Right side Expelled air Fresh air Electrical panel and filter inspection side Right side Expelled air Fresh air The illustrated…
-
Heat recovery unit UTNR-A Platinum 040÷500 Air flow rate: 400-4.700 m³/h Controls Full Controls Valves and actuators • KCV2 - Speed selector for wall mounting installation, to select from 3 speeds: Off/heating/ cooling switch; 3-speed switch; 230V power supply. • PCU - Control panel for wall mounting…
-
UTNRE-A Platinum p OPTIONAL T.E. V.M. OPTIONAL OPTIONAL OPTIONAL OPTIONAL Dp Dp T.A. S.Q.A. S.A.E. R.F.I. R.A.E. R.A.E. R.A. R.A. M F.P.S. F.P.S. F.P.S. F.P.S. H. + ^ĞnjŝŽŶĞ C. wat. coil section Ăƚƚ͘ĂĐƋ͘͘н&͘ Electrical ^ĞnjŝŽŶĞcoil section Ăƚƚ͘ĞůĞƚƚƌŝĐĂ KSBFR KBER - + V.R. S.EX. EXP. T.A.G. T.M. MAND.…
-
Web code: UTHE3 Heat recovery unit UTNR-HE Platinum 040÷400 Air flow rate: 310÷4,250 m³/h • Very high efficiency hygroscopic heat recovery Eurovent Certificate • Multi-speed or Brushless EC fans • F7 and M5 high efficiency filters • Double sandwich wall with high insulation capacity • Full control kit…
-
UTNR-HE PLATINUM MODEL 40 75 Type of Unit 1650 2400 3200 3800 n.d. Non-residential- Bidirectional Outdoor air filters F7 Return air filters M5 Bypass Motorisable side bypass damper TECHNICAL SPECIFICATIONS Nominal air flow m³/h 310 640 1000 STANDARD FANS ❶ Nominal available static pressure ❷…
-
Heat recovery unit UTNR-HE Platinum 040÷400 Air flow rate: 310÷4,250 m³/h PCU Panel • KPCUE Panel Controls User panels (for KRFCS) • KCV2-Speed selector for wall mounting installation, to select from 3 speeds (excluding model 40): Off/heating/cooling switch; 3-speed switch; 230V power supply. • PCU…
-
36 Controls FULL CONTROL The Full Control adjustment system aims to meet all the adjustment requirements of our units in the UTNA - UTNR A/P and HE comfort range starting from the most basic up to fully-equipped units. MAIN CONTROL LOGIC SETTINGS Temperature adjustment at a supply fixed point…
-
UTNA FUNCTION CONFIGURATIONS / FUNCTIONS AP TA AP TA 2-pipe single coil (Hot, Cold, Mixed) • • • • 4-pipe second coil (Hot, Mixed) • • • • Fan control 1, 2 or 3V • • • • Fan control control (operated manually from the control panel or from the external input/potentiometer or according to the…
-
Controls FULL CONTROL Separately supplied accessories ACTUATORS FOR ON-OFF 24V DAMPERS • KSEZM - Single-phase main disconnecting switch on the front of the electrical panel interrupts the power supply before allowing the door to be opened. It can be blocked with a padlock. Separately supplied…
-
Electrical panel in a resin case, with IP55 protection, compliant with IEC EN AMBIENT regulators for wall mounting with software application, display, 60204-1, complete with: • DDC programmable microprocessor controller that can manage up to 40 I/O with Rhoss software and configuration specifically…
-
Web code: UTHP1 Heat recovery unit UTNR-HP 035÷450 Air flow rate: 350÷4,500 m³/h • Combined crossed flow and active thermodynamic heat recovery • Standard air filter with G4 efficiency • Integrated electronics Fresh air terminal units with two-stage heat recovery unit. Construction features • Recovery…
-
ORIENTATION TYPE 01 ORIENTATION TYPE 02 ORIENTATION TYPE 1S ORIENTATION TYPE 2S Expelled air Fresh air Expelled air Fresh air The illustrated guidelines concerning the machine seen from above COMFORT | Compact heat recovery units 100÷5300 m³/h | UTNR-HP MODEL Nominal air flow m³/h 350 600 1000 1500…
-
Web code: VMC01 Heat recovery unit VMC-E 025÷130 Air flow rate: 250÷1.300 m³/h • Extremely compact • High efficiency recovery • Very silent • Brushless DC fans Fresh air terminal unit with counterflow static heat recovery. Controls Construction features • Galvanised sheet steel self-bearing structure…
-
VMC MODEL Nominal air flow m³/h 1000 1300 Nominal available static pressure Pa Total nominal absorbed power W Total maximum absorbed current Int S.F.P. A 0,5 0,6 0,6 1,4 2,1 2,7 W/m³/s ❶ Sound pressure dB(A) Electrical supply V-ph-Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 Speed number…
-
Advance - ADV Next Air 01÷16
-
Modular air handling units
800÷41000 m3/h
-
Web code: NA001 Advance ADV Next Air 01÷16 Air flow rate: 800÷41,000 m³/h • Highly performing new generation structure • Energy efficiency of excellence • Range ErP 2018 Ready • Plug and play integrated intelligence • Exclusive solutions exclusive for Indoor Air Quality Modular air handling units. •…
-
AHU N° 09.07.361 Range ADV STANDARD SET-UP Humidifiers The standard supply for each section is: • Pressure fitting that allows and facilitates the assembly of any sensors and the measurements of aeraulic performance required by the commissioning activities, as specified in the reference LEED guide. •…
-
A new comfort level
48 ® Air’suite filters the room air, making it healthy and clean, and breaks down microbiological agents, such as bacteria, mould and viruses, reaching a new IAQ standard (Indoor Air Quality) for indoor comfort. ADV Next Air Air Handling Units In 2016 comes to life Next Air, take place the new idea…
-
Perfect in any weather conditions
49 Thanks to the careful study of materials and the extreme attention payed to the thermal decoupling of the structure we can guarantee the absence of condensation in a very wide area of operating temperature and humidity both in summer and winter season. Thermal bridge factor Class TB1. The Our…
-
ADV
Next Air 3 new heat recovery systems Diversified recovery solutions • Vast choice of Erp 2018 recovery systems to meet various plant and climate needs Guaranteed performance • Eurovent Certification • Thorough Rhoss R&D laboratory testing Indirect adiabatic recovery Applying the ErP Directive to UNVR…
-
Range ADV
Monodirectional regenerative recovery Total comfort has become a must even in the summer, both for new and renovated systems. Air must be dehumidified to properly control humidity, by bringing it to between 14 and 12°C, then reheating it. This requires a heat source (boiler, electric coils) even in…
-
Heat recovery unit Monodirectional regenerative (RR) Air flow rate: 2800:30.000 m³/h • Summer modulating and free reheating without requiring hot fluids • Can be combined with every configuration and to all exhaust air recovery systems from sizes 06 to 16 included Regenerative heat recovery. Immediate…
-
Check Monodirectional recovery system for free pre-cooling and post-heating of the delivery air Winter Summer Air flow rate m³/h 8000 8000 8000 Air flow rate m³/h 8000 8000 Sum 30% post 8000 Temperature °C Temperature °C –5 Relative humidity % Relative humidity % Absolute humidity g/kg Absolute…
-
Heat recovery unit Monodirectional regenerative (RR) Air flow rate: 2800:30.000 m³/h
-
Seasonal operating logic Summer operation in recovery only If the hot power recovered with the pre-cooling coil is sufficient to post-heat the air coming out of the cold battery, the reheating is carried out using the heat of the air entering the machine. The temperature adjustment at the machine…
-
Heat recovery unit with indirect adiabatic cooling • Heat recovery system with maximised summer efficiency • Can be used in combination with every handling module in the range Heat recovery with indirect adiabatic cooling. Principle of operation To improve the performance of sensitive heat exchangers…
-
Recovery capacity (kW) Summer Energy Savings (10.000 m3/h) Indirect adiabatic recovery unit Characteristics and accessories Crossed flow aluminium recovery unit protected from corrosion by a special non-toxic epoxy paint, ensuring high resistance to the aggression of different types of water used…
-
Advance ADV Next Air 01÷16 ADV Next Air MODEL Air flow rates Air flow rate at 1.5 m/s m³/h 890 1160 1430 1770 2250 2860 3610 4360 Air flow rate at 2 m/s m³/h 1180 1550 1910 2360 3000 3820 4820 5820 Air flow rate at 2.5 m/s m³/h 1480 1930 2390 2950 3750 4770 6020 7270 Air flow rate at 3 m/s m³/h 1770…
-
ADV Next Air MODEL Air flow rates Air flow rate at 1.5 m/s m³/h 5180 6070 7160 8520 10160 12000 14450 17730 Air flow rate at 2 m/s m³/h 6910 8090 9550 11360 13550 16000 19270 23640 Air flow rate at 2.5 m/s m³/h 8640 10110 11930 14200 16930 20000 24090 29550 Air flow rate at 3 m/s m³/h 10360 12140…
-
INDOOR AIR QUALITY SOLUTIONS
-
® • Inactivation of bioburden Rhoss sets a new standard for “indoor” comfort by improving the hedonistic nature of the air delivered into the room by means of broad spectrum “biocidal filtration” treatment. • Zero energy impact Air’Suite® • No additional maintenance • Immediate retrofitting on…
-
® Air’Suite filter Breathe clean air, save your health & improve your productivity INDOOR & OUTDOOR HARMFUL POLLUTANTS DID YOU KNOW? B A C K G R O U N D TIME SPENT IN INDOOR ENVIRONMENTS 90% 24% DISEASES CAUSED BY ENVIRONMENTAL FACTORS TOBACCO DUST MITES GASES, VAPOURS BACTERIA RADON OZONE Building…
-
® Microbiological contamination of a confined environment. Noise reduction efficiency of Air’Suite Filter. % risk due to prolonged exposure indoor biological contamination % CONTAMINATION RISK DUE TO PROLONGED EXPOSURE BACTERIA POPULATION GROWTH days Air’Suite® filter Biocidal filtration Applying the…
-
Example of Air’Suite application RETURN EXPULSION SILENCER SUPPLY OUTDOOR AIR SILENCER contamination of indoor environment contamination of outdoor environment Available types of filters Research, development and certificates The Air’Suite® biocide filters are available in the following filtration…
-
Custom ADV - CTA ADV 240÷22920
Heat recovery unit - FLUXBLOCK Heat recovery unit - ROTOBLOCK
-
Customised air handling units
850÷104970 m³/h
-
Web code: CTCT Custom ADV CTA ADV 240÷22920 Air flow rate: 850÷104,970 m³/h • Wide and versatile range • Integrated heat regulation • Energy Saving Solutions • Self-sanitising units • Custom solutions Modular air handling units. • The CTA ADV range is based on decades of Rhoss experience in the field…
-
Custom ADV CTA ADV 240÷22920 STRUCTURE Construction details 60 ❶ Panels made of double sandwich sheet metal with interposed polyurethane insulation foam with a density of 40 kg/m³ and class 1 fire resistance, or rock wool with oriented and glued fibres with a density of 90 kg/m³ and class 0 fire…
-
AHU N° 09.07.361 Range ADV EN 779:2012 EN ISO 16890:2016 PM1 PM2,5 PM10 coarse particle efficiency (ePM) ePM1[95%] ePM1[90%] ePM1[85%] ePM1[80%] ePM1[75%] ePM1[70%] ePM1[65%] ePM1[60%] ePM1[55%] ePM1[50%] ePM2.5[95%] ePM2.5[90%] ePM2.5[85%] ePM2.5[80%] ePM2.5[75%] ePM2.5[70%] ePM2.5[65%] ePM2.5[60%]…
-
Custom ADV CTA ADV 240÷22920 Construction details • Drop separators: polypropylene, galvanised steel, aluminium and stainless steel droplet separators can be selected according to your needs. • Condensation drain pans: in galvanised steel with an inclined base to guarantee excellent drainage through…
-
HEAT RECOVERY UNITS HANDLING, PACKAGING AND SHIPPING All heat recovery units used are designed and selected to maximise the sensitive and/or latent efficiency and minimise the pressure drops on the air side so as not to burden the electric power absorbed by the fans. • The CTA ADV are available in…
-
Custom ADV CTA ADV 240÷22920 Adjustment • Plug&Play Unit • 360° service • Performance reliability When the regulation and power components of an air handling unit are normally installed on site the following occur simultaneously: • increased in installation costs (due to the on site restrictions…
-
AHU N° 09.07.361 Range ADV All-round support Rhoss offers all the support the customer may require putting all the skills, experience and professionalism at the customer’s disposal. Making the offer and defining the order: for the best choice Our technical sales team can accurately define the most…
-
Custom ADV CTA ADV 240÷22920 Adjustment Main technical features • ELECTRICAL PANEL installed on the machine and compliant with Directive IEC-EN 60204-1, complete with the programmed microprocessor regulator, transformers, drives for power control of the various utilities, safety devices and signal…
-
AHU N° 09.07.361 Range ADV Panel on the machine/ remote keypad Interfacing supervision systems Ambient panel Start-up assistance centre interface Interface Main functions: • collection of the "historical" data, updated as often as desired; • sending e-mails, SMS messages, faxes and voice calls if…
-
Custom ADV CTA ADV 240÷22920 Hospitals The Rhoss suggestion for the hospital sector The ADV health care range is designed according to the requirements of the European Standards EN 1886 and EN 13053 and certified by EUROVENT. All the components are selected and designed to obtain minimal energy…
-
FAN AND PUMP CONTROL “INTELLIGENT” FUNCTIONS External inverter controlled Plenum Fans or EC Brushless-type with control integrated directly in the electronics of the fan. • Integrated management of any redundant fans for totally guaranteed comfort and performance, even in the event of a fault. •…
-
CTA ADV Custom and Next Air Eurovent Certification WINTER In 2020 Eurovent finally introduced, in addition to the winter energy classification criteria of air handling units (introduced in 2010), also the new summer energy labels highlighting that the solutions applied to cold climates are not always…
-
SUMMER ENERGY EFFICIENCY CLASS Three types of summer air handling units The initial idea came from several tests carried out on hourly energy consumption, calculated in Europe, the Mideast, North Africa and some extreme meteorological locations for total of 58 locations. It helped to identify a…
-
CTA ADV Custom and Next Air Eurovent Certification • Guaranteed performance • Certainty of the results Eurovent certification is synonymous with absolute guarantee, according to standard parameters and protocols of the actual performance of the air handling units. The air handling units of the ADV…
-
AHU N° 09.07.361 Range ADV Classification criteria: Class Thermal transmittance K in W/m²K T5 No requirement T4 1,4<U<=2 T3 1<U<=1,4 T2 0,5<U<=1 T1 U<=0,5 • Thermal bridge factor of the casing. Differential ratio between the minimum temperature at any point on the outer surface of the unit and the…
-
CTA ADV Custom and Next Air SELECTION SOFTWARE • SIMPLE to install and use • FLEXIBLE when selecting RHOSS units in work conditions • EFFECTIVE and COMPLETE in useful results for the designer • The innovative selection software of the CTA ADV range allows fast and correct sizing of the units. The…
-
PROFESSIONAL | Customised air handling units 850÷104970 m³/h |
-
1. Exclusive energy analysis tools An air handling unit must not only be selected according to its initial price but also considering the costs generated by its use. To help you choose the type of heat recovery that is the most economic and energy convenient for your specific application, Rhoss…
-
AHU N° 09.07.361 Range ADV Selecting the layout and type of heat recovery to be used 2. Selecting the layout and type of heat recovery to be used Return fan NO YES Remote Integrated RRM Recovery Regenerative Mono-directional RBG Recovery Twin Coils Heat exchange type Sensitive and latent Sensitive…
-
CTA ADV Custom and Next Air ENERGY SAVING ❶ ❷ ❶ TWIN RECOVERY Principle of operation MONODIRECTIONAL REGENERATIVE RECOVERY Principle of operation • Recovery with twin coils consists of hydraulically connecting a finned coil in a closed circuit placed on the supply flow and on the exhaust flow. •…
-
AHU N° 09.07.361 Range ADV ❸ ROTARY RECOVERY Principle of operation • The air-air rotary heat recovery units used by Rhoss consist of a cylindrical rotor containing thousands of channels and distinguished by a very high surface development and are driven by an electric motor equipped with a speed…
-
Web code: CTFB Heat recovery unit FLUXBLOCK Air flow rate: 2000÷22000 m³/h • Maximised energy saving without admixture of the flows • EC high efficiency fan use • Extremely silent • Full Control Option • Can be integrated into existing traditional-type systems Crossed flow heat recovery. Principle of…
-
FLUXBLOCK MODEL 570 920 1280 2080 2920 3600 4300 5250 6060 m³/h 2.000 3.500 5.000 7.000 10.000 12.500 15.500 18.500 22.000 MAX m³/h 3.500 4.800 5.700 8.200 11.000 15.000 17.500 21.000 22.500 MIN m³/h 500 1.000 1.000 2.000 2.000 4.000 4.000 5.000 5.000 Available delivery/return static pressure Pa…
-
Web code: CTRB Heat recovery unit ROTOBLOCK Air flow rate: 2500÷22000 m³/h • Maximised energy savings • EC high efficiency fan use • Extremely silent • Full Control Option • Can be integrated into existing traditional-type systems Rotary heat recovery. Principle of operation What makes the air…
-
ROTOBLOCK MODEL 710 1070 1530 2080 2500 2920 3270 4300 5250 6060 m³/h 2.500 4.000 5.500 7.000 9.000 11.500 15.000 18.000 20.000 22.000 MAX m³/h 3.600 5.000 6.000 8.000 9.500 10.500 12.500 15.500 18.000 21.500 MIN m³/h 750 800 1.200 2.000 2.500 2.500 3.000 4.000 4.000 5.000 Nominal air flow (SFP v<=2…
-
Dry-Pool - DAESY-DRESY-DTESY-DEESY 108÷2140
-
Pool dehumidifiers
2200÷27000 m3/h
-
Web code Dry-Pool: DP001 Web code DAFC-DAHR: DPM01 Dry-Pool DAESY-DRESY-DTESY-DEESY 108÷2140 Dehumidification capacity: 8÷140 l/h • R410A • Integrated regulation • Double panels • Thermal cut profiles • Version with brushless EC fans Air and/or water cooled centrifugal fan POOL DEHUMIDIFIERS. Range…
-
(D~ESY; D~ESY+BA; D~ESY+DAHR; D~ESY+BA+DAHR). The presence of the DAFC module and/or BE accessory does not modify the available static pressure. • VM EC - Brushless EC type of delivery fan with impeller made of corrosion resistant composite plastic with backward curved wing profile blades. • Static…
-
Dry-Pool DAESY-DRESY-DTESY-DEESY 108÷2140 ADDITIONAL FRESH AIR HANDLING UNIT MODULES DAHR: HEAT RECOVERY MODULE. Construction features DAFC: FREE-COOLING MODULE. Construction features • Fan: dual intake centrifuge with backward impeller blades that are statically and dynamically balanced, taper…
-
Examples of combinations between the dehumidifier and the additional module DRESY/DTESY + BA + DAFC Expulsion Fresh M M SUPPLY AIR Pool hydraulic circuit – + + M + Pool RETURN FAN M Boiler DRESY/DTESY + BA + DAHR M M SUPPLY AIR Pool hydraulic circuit – + + M + Pool RETURN FAN M Boiler DEESY + BA +…
-
Dry-Pool DAESY-DRESY-DTESY-DEESY 108÷2140 DAESY-DRESY-DTESY-DEESY MODEL l/h 7,7 11,3 13,1 16,5 19,5 25,2 28,0 33,0 kW 12,6 18,8 23,0 30,1 33,9 43,7 49,6 57,6 kW 3,2 4,9 5,4 7,0 7,4 10,0 11, 3 13,1 Scroll/step compressor no. 1/1 1/1 1/1 1/1 1/1 1/1 1/1 1/1 Fans/Motors no. 1/1 1/1 1/1 1/1 1/1 1/1 1/1…
-
Dry-Pool SELECTION SOFTWARE FROM THE SYSTEM TO THE DEHUMIDIFIER. • Other elements such as the number of pools and their water volume, the cubic volume of the room, the number of spectators and the presence of special water games are also taken into consideration for a more accurate selection. • The…
-
INDUSTRY RHOSS INDUSTRY: a team of professionals at the service of the industry. RHOSS INDUSTRY can develop solutions, products and services for the industrial sectors in which the processing or transformation of a product require precise control of the temperature and humidity parameters with the…
-
A global organisation with companies and a presence worldwide NIBE Group is a global organisation that contributes to a smaller carbon footprint and better utilisation of energy. In its three business areas – Climate Solutions, Element and Stoves – we develop, manufacture and market a wide range of…
-
AIR HANDLING SYSTEMS
RhossOfficialChannel Rhoss RHOSS S.P.A. Via Oltre Ferrovia, 32 - 33033 Codroipo (UD) - Italy tel. +39 0432 911611 - rhoss@rhoss.it www.rhoss.it - www.rhoss.com Italy Sales Departments: Codroipo (UD) 33033 Via Oltre Ferrovia, 32 tel. +39 0432 911611 Nova Milanese (MB) 20834 Via Venezia, 2 - p. 2 tel.…