Explanation of Symbols
DANGER Indicates a hazardous situation that, if not avoided, will result in death or serious injury. WARNING Indicates a hazardous situation that, if not avoided, could result in death or serious injury. CAUTION Indicates a hazardous situation that, if not avoided, may result in minor or moderate…
-
Appliance filled with flammable gas R32
Before use the appliance, read the owner’s manual first. Before install the appliance, read the installation manual first. Before repair the appliance, read the service manual first. The Refrigerant To realize the function of the air conditioner unit, a special refrigerant circulates in the system.…
-
Operation and Maintenance
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards…
-
Maintenance must be performed by qualified
professionals. Otherwise, it may cause personal injury or damage. Do not repair air conditioner by yourself. It may cause electric shock or damage. Please contact dealer when you need to repair air conditioner. Do not extend fingers or objects into air inlet or air outlet. It may cause personal…
-
Attachment
Installation must be performed by qualified professionals. Otherwise, it may cause personal injury or damage. Must follow the electric safety regulations when installing the unit. According to the local safety regulations, use qualified power supply circuit and circuit break. Do install the circuit…
-
Do not put through the power before finishing installation
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube. The appliance shall be installed…
-
For the air conditioner with plug, the plug should be
reachable after finishing installation. For the air conditioner without plug, an circuit break must be installed in the line. If you need to relocate the air conditioner to another place, only the qualified person can perform the work. Otherwise, it may cause personal injury or damage. Select a…
-
Parts Name
Indoor Unit air outlet display and button display and button panel air inlet FAN ON/OFF FUNC. MODE (Display content or position may be different from above graphics, please refer to actual products) remote controller Outdoor Unit air inlet handle air outlet NOTICE: Actual product may be different…
-
Button’s Name and Function
1 ON/OFF button 2 MODE button 3 FAN button 4 FUNCTION button 5 3 FAN ON/OFF 1 5 ▼/▲ button 4 FUNC. MODE 2 6 / button 6 Introduction for icons on display screen of air conditioner temperature Operation Timer Ambient or set temperature display display display or others E-Heater display Cooling display…
-
Button’s introduction
Note: This series unit adopts touch buttons. You only need to touch the buttons slightly. 1 ON/OFF button ● Press this button to turn on or turn off the unit.(Note: Under X-FAN mode, press this button to turn on the unit directly.) 2 MODE button ● Every time press this button, the mode will…
-
Button’s introduction
5 ▼/▲ button ● After each pressing of "▲" or "▼" button, set temperature will increase or decrease 1℃. Temperature adjustment range is 16℃~30℃. This button is invalid under auto mode. Timer setting can be set in 1h increment among 0~24h. When it is adjusted to auxiliary heating function setting…
-
Buttons on remote controller
2 ON/OFF button 2 SAVE button 3 FAN button 4 MODE button 5 ▲/ 6 HEAT button 7 COOL button 8 button 9 button ▲ 1 1 button 3 10 SLEEP button 5 11 WiFi button X-FAN/E-HEATER button QUIET button LIGHT button TIMER button Introduction for icons on display screen { Operation mode Set fan speed (No fan…
-
● This is a general use remote controller, it could be used for the air conditioners
with multifunction; For some function, which the model doesn't have, if press the corresponding button on the remote controller that the unit will keep the original running status. ● After putting through the power, the air conditioner will give out a sound. Operation indictor " " is ON. After that…
-
MODE button Press this button to select your required operation mode. AUTO COOL DRY FAN HEAT ● When selecting auto mode, air conditioner will operate automatically according to the sensed temperature. Set temperature can’t be adjusted and will not be displayed as well. Press "FAN" button can adjust…
-
Cool button ● Press this button, unit will operate in cool mode. 7 Heat button ● Press this button, unit will operate in heat mode. 8 button ● Under simple swing mode, pres this button can turn on (" " icon is displayed) or turn off (" " icon is not displayed) the left&right swing function. ● When…
-
10 SLEEP button
Under COOL, or HEAT mode, press this button to start up sleep function. " " icon is displayed on remote controller. Press this button again to cancel sleep function and " " icon will disappear.After powered on, Sleep Off is defaulted. After the unit is turned off, the Sleep function is canceled. In…
-
15 TIMER button
● At ON status, press this button once can set TIMER OFF. The character of HOUR ▲ TIMER ON. After each pressing of "▲ " or " " button, time will increase or decrease half an hour. When holding " ▲ " or " " button, 2s later, the time will change quickly until to ▲ ▲ ▲ Cancel TIMER OFF: Press "TIMER"…
-
Operation guide
1. After putting through the power, press "ON/OFF" button on remote controller to turn on the air conditioner. 2. Press "MODE" button to select your required mode: AUTO, COOL, DRY, FAN, HEAT. 3. Press "▲" or " " button to set your required temperature. (Temperature can’t be adjusted under auto…
-
Clean and maintenance
Note: ■ Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock. ■ Do not wash the air conditioner with water to avoid electric shock. ■ Do not use volatile liquid to clean the air conditioner. Clean surface of indoor unit When the surface of…
-
Clean and maintenance
NOTICE: Checking before use-season 1. Check whether air inlet and air outlet are blocked. 2. Check whether air switch, plug and socket are in good condition. 3. Check whether filter is clean. 4. Check whether the remote controller is installed with batteries. 5. Check whether mounting bracket for…
-
General phenomenon analysis
Please check below items before asking for maintenance. If the malfunction still can’t be eliminated, please contact local dealer or qualified professionals. Phenomenon Check items Solution ● Whether it's interfered severely ● Pull out the plug. Reinsert (such as static electricity, stable the plug…
-
Phenomenon
Check items Solution Mist is emitted ● Indoor temperature and humfrom indoor idity is high? unit’s air outlet No air emitted from indoor unit ● Air inlet or air outlet of indoor unit is blocked? ● Eliminate obstacles. ● Under heating mode, indoor temperature is reached to set temperature? ● After…
-
Phenomenon
Check items Solution Air conditioner ● Whether there’s interference, operates such as thunder, wireless normally devices, etc. suddenly ● Disconnect power, put back power, and then turn on the unit again. Outdoor unit has vapor ● During defrosting under heating mode, it may generate vapor, which is…
-
Error code
● When air conditioner status is abnormal, temperature indictor on indoor unit will blink to display corresponding error code. Please refer to below list for identification of error code. Error code H3 H6 E1 E3 E4 E5 E6 E8 e6 Troubleshooting It can be eliminated after restarting the unit. If not…
-
ab
-
Safety precautions for installing and relocating the unit
To ensure safety, please be mindful of the following precautions. Warning When installing or relocating the unit, be sure to keep the refrigerant circuit free from air or substances other than the specified refrigerant. Any presence of air or other foreign substance in the refrigerant circuit will…
-
Tools for installation
1 Level meter 2 Screw driver 3 Impact drill 4 Drill head 5 Pipe expander 6 Torque wrench 7 Open-end wrench 8 Pipe cutter 9 Leakage detector 10 Vacuum pump 11 Pressure meter 12 Universal meter 13 Inner hexagon spanner Note: 14 Measuring tape ● Please contact the local agent for installation. ● Don't…
-
Requirements for electric connection
Safety precaution 1. Must follow the electric safety regulations when installing the unit. 2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard. 3. According to the local safety regulations, use…
-
Step one: choosing installation location
Recommend the installation location to the client and then confirm it with the client. Step two: open piping hole 1. Choose the position of piping hole according to the direction of outlet pipe. 2. Open a piping hole with the diameter of Ф70 on the selected outlet pipe position. In order to drain…
-
open-end wrench
2. Aim the pipe joint at the corresponding bellmouth. union nut pipe torque wrench pipe joint indoor pipe union nut pipe 3. Pretightening the union nut with hand. 4. Adjust the torque force by referring to the following sheet. Place the openend wrench on the pipe joint and place the torque wrench on…
-
2. Remove the wire clip; connect the power connection wire to the wiring terminal
according to the color; tighten the screw and then fix the power connection wire with wire clip. N(1) 2 3 blue black brown yellowgreen Outdoor unit connection 3. Adjust the position of upper and lower adjusting baffle; clamp the connection pipe and drain pipe as firm as possible. 4. Tighten the…
-
2. Reserve a certain length of drain hose and power cord for installation when
binding them. When binding to a certain degree, separate the indoor power and then separate the drain hose. connection pipe drain hose band indoor power cord 3. Wrap it evenly, and rolling width should be 1/3 of bandaging belt. Do not wrap it too tight or too loose. 4. The liquid pipe and gas pipe…
-
Step one: fix the support of outdoor unit
(select it according to the actual installation situation) 1. Select installation location according to the house structure. 2. Fix the support of outdoor unit on the selected location with expansion screws. Note: ● Take sufficient protective measures when installing the outdoor unit. ● Make sure…
-
Step four: connect indoor and outdoor pipes
1. Remove the front side plate or handle. pipe joint union nut handle 3. Pretightening the union nut with hand. 4. Tighten the union nut with torque wrench by referring to the sheet below. 2. Remove the screw cap of valve and aim the pipe joint at the bellmouth of pipe. liquid pipe liquid valve…
-
2. Fix the power connection wire and
signal control wire with wire clip (only for cooling and heating unit). Note: ● After tightening the screw, pull the power cord slightly to check if it is firm. ● Never cut the power connection wire to prolong or shorten the distance. Step six: neaten the pipes 1. The pipes should be placed along…
-
Vacuum pumping
Use vacuum pump piezometer 1. Remove the valve caps on the liquid valve and gas valve and the nut of refrigerant charging vent. 2. Connect the charging hose of piezogas valve liquid valve meter to the refrigerant charging vent valve cap of gas valve and then connect the other charging hose to the…
-
Check after installation
Items to be checked Possible malfunction The unit may drop, shake or emit noise. Have you done the refrigerant leakage test? (heating) capacity. It may cause condensation and water dripping. Is water drained well? It may cause condensation and water dripping. Is the voltage of power supply according…
-
Installation instructions of anti-collapse chain
● In order to prevent accidental collapse of indoor unit, please install the anti-collapse chain. Installation steps: 1. Remove the screw of anti-collapse hole at the top cover of indoor unit (see fig. 3); 2. Take out the anti-collapse chain and put it into the anti-collapse hole, and then tighten…
-
Configuration of connection pipe
1. Standard length of connection pipe ● 5m, 7.5m, 8m. 2.Min. length of connection pipe is 3m. 3.Max. length of connection pipe. Cooling capacity Max length of connection pipe Cooling capacity Max length of connection pipe 5000Btu/h (1465W) 15 24000Btu/h (7032W) 25 7000Btu/h (2051W) 15 28000Btu/h…
-
таблицы и схемы — в просмотре
-
Pipe expanding method
Note: Improper pipe expanding is the main cause of refrigerant leakage. Please expand the pipe according to the following steps: A: Cut the pipe E: Expand the port ● Expand the port with expander. the distance of indoor unit and outdoor unit. ● Cut the required pipe with pipe cutter. hard mold…
-
NOTE CONCERNING PROTECTION OF
ENVIRONMENT This product must not be disposed of via normal household waste after its service life, but must be taken to a collection station for the recycling of electrical and electronic devices. The symbol on the product, the operating instructions or the packaging indicate such disposal…
Схемы, таблицы и рисунки — в просмотре документа выше. Клик по номеру страницы открывает её в просмотре.