USER'S MANUAL
MULTI COMBI SERIES FLOOR&CEILING MC-F09,12,18,24AI
-
User Notice
◆ When operating, the entire capacity of the cooperating indoor unit should be not larger than 150% of outdoor unit. Otherwise, it will cause the shortage of cooling (heating) capacity. ◆ The power supply of the entire unit must be the power supply of outdoor unit. And disconnect the main power of…
-
Ⅰ Wired Controller XK19
1 Wired Controller XK19 It is optional for the cassette type, wall-mounted, and floor ceiling indoor units. 1.1 Outside View of the Wired Controller Fig.1 Outside View of the Wired Controller 1.2 LCD of the Wired Controller Fig.2 LCD of the Wired Controller 1
-
1.3 Introduction to the Symbols on LCD
Table 1 No. Symbols Description 1 Swing function. 2 Sleep function (3 types: sleep 1,sleep2 and sleep 3). 3 Running modes of the indoor unit (Cooling, Dry, Fan and Heating). 4 Defrosting function for the outdoor unit. 5 Gate-control function (this function is yet unavailable for this unit). 6 Lock…
-
2.2 Function of the Buttons
Table 2 No. Name 1 Enter/cancel 2 ▲ 6 ▼ Function ① Function selection and cancellation. ② Press it for 5s to examine the outdoor ambient temperature. ① Running temperature setting of the indoor unit, range:16 ~ 30℃ . ② Timer setting, range:0.5-24 hr. ③ Switchover between quiet/auto quiet or among…
-
3.3 Temperature Setting
Press ▲or ▼ to increase/decrease the preset temperature. If press either of them continuously, the temperature will be increased or decreased by 1℃ every 0.5s,as shown in Fig.6. In the Cooling, Dry or Heating mode, the temperature setting range is 16℃~ 30℃ . In the Fan mode, the setting temperature…
-
Timer off setting under the “On” state of the unit is shown as Fig.8
Fig. 8 Timer off Setting under the “On” State of the Unit Timer range: 0.5-24hr. Every press of ▲or ▼ will make the set time increased or decreased by 0.5hr. If either of them is pressed continuously, the set time will increase/ decrease by 0.5hr every 0.5s. 3.6 Swing Setting Swing On: Press…
-
Fig. 9 Swing Setting
Note: ① . Sleep, Save, Turbo, Blow or Quiet setting is the same as the Swing setting. ② . After the setting has been done, it has to press the key “Enter/cancel” to back to the setting status or quit automatically five seconds later. 3.7 Sleep Setting Sleep on: Press Function under on state of the…
-
Fig. 10 Sleep Setting
Sleep off is default after power failure and then power recovery, and the sleep functions is unavailable under the fan mode. There are three Sleep modes: Sleep 1, Sleep 2 and Sleep 3. a. Sleep 1 In the Cooling or Dry mode, the temperature will increase by 1℃ after the unit runs under Sleep 1 for 1hr…
-
For example, the temperature in the Heating mode is set at 22 ℃ .Under the mode of Sleep2, the
temperature will decrease by 1 ℃ every 1hr. After it decreases by 2 ℃ in total, i.e. 20 ℃ ,the unit will keep running at 20℃ . c. Sleep 3 Sleep curve setting under Sleep 3(DIY mode) d. Under the mode of Sleep 3, press Timer to enter the Sleep setting. In this case, “1 HOUR” is displayed where the…
-
When the Turbo function is activated, press Function to enter the Turbo setting interface and then press Enter/Cancel to cancel this function. Turbo function setting is as shown in Fig.14. Fig.14 Turbo Setting Notes: ① . When the Turbo function is activated, if the difference between the room…
-
Fig. 15 Saving Setting for Cooling
Save Setting for Heating: Under on state or in the Heating mode of the unit, press Function to enter the Save setting interface and then press ▲or ▼ to adjust upper limited value in the Heating mode. After that, press Enter/Cancel to activate the Save function for heating. The upper initial limited…
-
Fig.16 Save Setting for Heating
Notes: ① . If press Function on the Save setting interface or if there is not any operation for 5s after last button press, the Save setting will be canceled automatically by the system, with memorizing the present setting data. ② . When power is on after the power failure, the Save function will be…
-
Fig.17 E-heater Setting
3.11 Blow Setting Blow function: After the unit is turned off, the water in evaporator of indoor unit will be automatically evaporated to avoid mildew. In the Cooling or Dry mode, press Function till the unit enters the Blow setting interface and then press Enter/Cancel to active this function. When…
-
Fig.18 Blow Setting
Notes: ① . When the Blow function is activated, if turning off the unit by pressing On/Off or by the remote controller, the indoor fan will run at the low fan speed for 10 min, with “BLOW” displayed on the LCD. While, if the Blow function is deactivated, the indoor fan will be turned off directly. ②…
-
Fig.19 Quiet Setting
Notes: ① . When the Quite function is activated, the fan speed is low and un-adjustable. ② . When the Auto Quite function is activated, the unit will run according to the difference between the room temperature and the setting temperature. In this case, the fan speed is adjustable. Difference…
-
Memory recovery: If this function has been set for the wired controller, the wired controller after power failure will resume its original running state upon power recovery. Memory contents: On/Off, Mode, set temperature, set fan speed, Save function and Lock function. c. Enquiry of the Outdoor…
-
Table 3 Meaning of Each Error
Error Code Error High pressure protection E1 Low pressure protection E3 Discharge protection E4 Over-current protection P5 Communication error E6 Indoor water overflow protection E9 Mode conflict E7 Anti-freezing protection E2 Defrosting or oil returning for heating H1 Indoor ambient temperature…
-
Ⅱ Wireless Remote Controller YT1F
Notes: ① . Be sure that there are no obstructions between the receiver and the remote controller; ② . Do not drop or throw the remote controller; ③ . Do not let any liquid into the remote controller and expose the remote controller to direct sunlight or any place where is very hot. ④ . This is a…
-
4) FAN
Auto, Low, Middle, or High fan speed can circularly selected by pressing this button. After powered on, the default is Auto speed. Under Dehumidifying mode, only Low fan speed is available. 5) CLOCK The clock can be set up by pressing this button, with the symbol displayed and blinking. In such a…
-
This kind of remoter controller is universal. And the three swing statuses of
are the same as that of . If the swing function is deactivated when the air guide louver is swing up and down, it will stop at the current position. indicates that the air guide louver swings up and down among all five positions. 13) AIR ( ) AIR ON or Air OFF can be selected by pressing this button.…
-
② . BLOW OFF: When press the ON/OFF button to turn off the unit, the whole unit will be stopped
completely. b. About AFTERHEAT BLOW Under the Heat mode or Auto Heat mode, if the unit is turned off, the compressor and outdoor fan will stop running immediately and the upper and lower guide board will rotate to the horizontal position, while the indoor fan will still run at the low fan speed.…
-
Ⅰ Safety Information
Please read this manual carefully before use this unit, and operate it correctly according to the guide in this manual. Please take specially note to the meaning of these two marks: Warning! This mark means that it may cause casualty or badly hurt if the operation is incorrect. Caution! This mark…
-
Ⅱ Selection of Installation Location and Precautions
1 Selection of Installation Location for Air Conditioner Unit The installation of air conditioner unit must be in accordance with national and local safety codes. Installation quality will directly affect the normal use of air conditioner unit. The user is prohibited from installation by himself.…
-
Ⅲ Installation of Floor And Ceiling Type Indoor Unit
1 Space dimension for installation of the unit The space around the unit is adequate for ventilation. (Refer to Fig.1) Fig.1 2 Important notice a. The unit must be installed by the professional personnel according to this install instruction to ensure the well use. Please contact the local NEPA…
-
* Loosen two hanger bracket setting bolts (M8) on eath side for less than 10mm. Remove two hanger
bracket fixing bolts (M6) on the rear side. Detach the hanger bracker by pulling it backward (Refer to Fig.5). Fig.2 Fig.3 c. Set the suspension bolt. (Use W3/8 or M10 size suspension bolts) * Adjust the distance from the unit to the ceiling slab beforehand. (Refer to Fig.4) d. Fix the hanger…
-
Celling
Hanger bracket 40 or less Hanger bracket setting bolt(M8) Suspension bolt Hanger bracket fixing bolt(M6) Hanger bracket Fig.4 Fig.5 Celling slab BOLT POSITION INWARD Hanger bracket Fig.7 Fig.6 Fig.8 Fig.9 When installing the indoor unit, you can refer the paper pattern for installation, and make…
-
4 Electrical wiring
Caution: The power of every indoor unit should be connected in outdoor unit. a. Open surface panel. b. Remove the electrical box cover. c. Route the power connection cord from the back of the indoor unit and pull it toward the front through the wiring hole upward. d. Connect the wiring…
-
MC-E36AI
POWER INDOOR UNIT A INDOOR UNIT B INDOOR UNIT C INDOOR UNIT D XT5X T4 XT3X T2 N L XT1 OUTDOOR UNIT Caution ! ① . The incorrect of wiring connecting would lead malfunction of some of the electric elements. ② . Make sure that the lead between the connect end and the clamp end has some need space after…
-
Large seeing pad⑤ (Accessory) Cramp⑤ (Accessory) Air outlet Watering can m 4m or le ss Fig.12 Fig.13 Fig.14 6 Install the connection pipes Connect the connect pipe with the two relative leading pipe, tie the nut on tie–in of the connect pipe tightly. Caution ! * Be careful in bending the connection…
-
Ⅳ Constitutes and Names of Every Part of Floor And Ceiling Type
Indoor Unit Air outlet Guide louver Surface Panel Air filter, purifier (in air inlet grille) Air inlet Connecting pipe Suitable model: MC-F09AI, MC-F12AI, MC-F18AI, MC-F24AI Note:The appearances will be same by the different models of air conditioners. 9
-
Ⅴ Working Temperature Range
Working Temperature Range Indoor side state 10 Outdoor side state Dry bulb temp. ℃ Wet bulb temp.℃ Dry bulb temp. ℃ Wet bulb temp. ℃ Rated. Cooling Max. cooling Min. cooling — Rated. Heating Max. heating 27 — 24 18 Min. heating 20 15 - 15 - 16
-
Ⅵ Maintenance Method
Warning! ① . Do turn off the unit and cut off the main power supply when cleaning the air conditioner, otherwise electric shock may happened. ② . Do not make the air conditioner wet or electric shock may be lead; Ensure that the air conditioner will not be cleaned by water rinsing under any…
-
Ⅶ Operating Instructions
12 * The temperature should not be set lower than what you need. This would lead to increase energy cost. * To distribute cool air throughout the room, adjust airflow direction as shown by the arrows (see picture) to diffuse cool air. * Clean the air filter every week for higher efficiency by…
-
* Check electrical system (voltage and
frequency). Use the power supply indicated on the unit to operate the air conditioner and only fuses with specified capacity it should be done by professional. Do not use pieces of wire instead of fuse. * Do not insert objects into the air inlet or outlet when the air conditioner is running as it…
-
Ⅷ Malfunction Analyzing
Warning ! Do not repair air conditioner by yourself for the incorrect repair would lead electric shock or fire. Please contact service center and had the unit repaired by specialized personnel. Check the following item before contacting to repair could save your time and cost. Malfunction Phenomena…