USER'S MANUAL
-
User Notice
◆ The total capacity of the indoor units which runs at the same time can not exceed 150% of that of the outdoor units; otherwise, the cooling (heating) effect of each indoor unit would be poor. ◆ Switch the main power on 8 hours before start the unit, helpful for a successful startup. ◆ It is a…
-
Ⅰ Wired Controller XK19
1 Wired Controller XK19 It is optional for the cassette type, wall-mounted, and floor ceiling indoor units. 1.1 Outside View of the Wired Controller Fig.1 Outside View of the Wired Controller 1.2 LCD of the Wired Controller Fig.2 LCD of the Wired Controller 1
-
1.3 Introduction to the Symbols on LCD
Table 1 No. Symbols Description 1 Swing function. 2 Sleep function (3 types: sleep 1,sleep2 and sleep 3). 3 Running modes of the indoor unit (Cooling, Dry, Fan and Heating). 4 Defrosting function for the outdoor unit. 5 Gate-control function (this function is yet unavailable for this unit). 6 Lock…
-
2.2 Function of the Buttons
Table 2 No. Name 1 Enter/cancel 2 ▲ 6 ▼ Function ① Function selection and cancellation. ② Press it for 5s to examine the outdoor ambient temperature. ① Running temperature setting of the indoor unit, range:16 ~ 30℃ . ② Timer setting, range:0.5-24 hr. ③ Switchover between quiet/auto quiet or among…
-
3.3 Temperature Setting
Press ▲or ▼ to increase/decrease the preset temperature. If press either of them continuously, the temperature will be increased or decreased by 1℃ every 0.5s,as shown in Fig.6. In the Cooling, Dry or Heating mode, the temperature setting range is 16℃~ 30℃ . In the Fan mode, the setting temperature…
-
Timer off setting under the “On” state of the unit is shown as Fig.8
Fig. 8 Timer off Setting under the “On” State of the Unit Timer range: 0.5-24hr. Every press of ▲or ▼ will make the set time increased or decreased by 0.5hr. If either of them is pressed continuously, the set time will increase/ decrease by 0.5hr every 0.5s. 3.6 Swing Setting Swing On: Press…
-
Fig. 9 Swing Setting
Note: ① . Sleep, Save, Turbo, Blow or Quiet setting is the same as the Swing setting. ② . After the setting has been done, it has to press the key “Enter/cancel” to back to the setting status or quit automatically five seconds later. 3.7 Sleep Setting Sleep on: Press Function under on state of the…
-
Fig. 10 Sleep Setting
Sleep off is default after power failure and then power recovery, and the sleep functions is unavailable under the fan mode. There are three Sleep modes: Sleep 1, Sleep 2 and Sleep 3. a. Sleep 1 In the Cooling or Dry mode, the temperature will increase by 1℃ after the unit runs under Sleep 1 for 1hr…
-
For example, the temperature in the Heating mode is set at 22 ℃ .Under the mode of Sleep2, the
temperature will decrease by 1 ℃ every 1hr. After it decreases by 2 ℃ in total, i.e. 20 ℃ ,the unit will keep running at 20℃ . c. Sleep 3 Sleep curve setting under Sleep 3(DIY mode) d. Under the mode of Sleep 3, press Timer to enter the Sleep setting. In this case, “1 HOUR” is displayed where the…
-
When the Turbo function is activated, press Function to enter the Turbo setting interface and then press Enter/Cancel to cancel this function. Turbo function setting is as shown in Fig.14. Fig.14 Turbo Setting Notes: ① . When the Turbo function is activated, if the difference between the room…
-
Fig. 15 Saving Setting for Cooling
Save Setting for Heating: Under on state or in the Heating mode of the unit, press Function to enter the Save setting interface and then press ▲or ▼ to adjust upper limited value in the Heating mode. After that, press Enter/Cancel to activate the Save function for heating. The upper initial limited…
-
Fig.16 Save Setting for Heating
Notes: ① . If press Function on the Save setting interface or if there is not any operation for 5s after last button press, the Save setting will be canceled automatically by the system, with memorizing the present setting data. ② . When power is on after the power failure, the Save function will be…
-
Fig.17 E-heater Setting
3.11 Blow Setting Blow function: After the unit is turned off, the water in evaporator of indoor unit will be automatically evaporated to avoid mildew. In the Cooling or Dry mode, press Function till the unit enters the Blow setting interface and then press Enter/Cancel to active this function. When…
-
Fig.18 Blow Setting
Notes: ① . When the Blow function is activated, if turning off the unit by pressing On/Off or by the remote controller, the indoor fan will run at the low fan speed for 10 min, with “BLOW” displayed on the LCD. While, if the Blow function is deactivated, the indoor fan will be turned off directly. ②…
-
Fig.19 Quiet Setting
Notes: ① . When the Quite function is activated, the fan speed is low and un-adjustable. ② . When the Auto Quite function is activated, the unit will run according to the difference between the room temperature and the setting temperature. In this case, the fan speed is adjustable. Difference…
-
Memory recovery: If this function has been set for the wired controller, the wired controller after power failure will resume its original running state upon power recovery. Memory contents: On/Off, Mode, set temperature, set fan speed, Save function and Lock function. c. Enquiry of the Outdoor…
-
Table 3 Meaning of Each Error
Error Code Error High pressure protection E1 Low pressure protection E3 Discharge protection E4 Over-current protection P5 Communication error E6 Indoor water overflow protection E9 Mode conflict E7 Anti-freezing protection E2 Defrosting or oil returning for heating H1 Indoor ambient temperature…
-
Ⅱ Wireless Remote Controller YT1F
Notes: ① . Be sure that there are no obstructions between the receiver and the remote controller; ② . Do not drop or throw the remote controller; ③ . Do not let any liquid into the remote controller and expose the remote controller to direct sunlight or any place where is very hot. ④ . This is a…
-
4) FAN
Auto, Low, Middle, or High fan speed can circularly selected by pressing this button. After powered on, the default is Auto speed. Under Dehumidifying mode, only Low fan speed is available. 5) CLOCK The clock can be set up by pressing this button, with the symbol displayed and blinking. In such a…
-
This kind of remoter controller is universal. And the three swing statuses of
are the same as that of . If the swing function is deactivated when the air guide louver is swing up and down, it will stop at the current position. indicates that the air guide louver swings up and down among all five positions. 13) AIR ( ) AIR ON or Air OFF can be selected by pressing this button.…
-
② . BLOW OFF: When press the ON/OFF button to turn off the unit, the whole unit will be stopped
completely. b. About AFTERHEAT BLOW Under the Heat mode or Auto Heat mode, if the unit is turned off, the compressor and outdoor fan will stop running immediately and the upper and lower guide board will rotate to the horizontal position, while the indoor fan will still run at the low fan speed.…
-
Safety Precautions
Ⅰ Safety Precautions Please read this manual carefully before use and operate correctly as instructed in this manual. Please especially take notice of the following two symbols: Warning! It indicates improper operation which will lead to human casualty or sever injury. Cuation! It indicates improper…
-
Installation Location and Matters Needing Attention
Ⅱ Installation Location and Matters Needing Attention The installation of the unit must comply with the national and local safety regulations. The installation quality directly affects the normal use, so the user should not carry out the installation personally. Instead, the installation and…
-
Installation Location and Matters Needing Attention
① Running water pipe; ② Coal gas pipe; ③ Sewage pipe; ④ Other places where the professional personnel think unreliable. 4 Accessories for Installation Refer to the packing list for the accessories of the indoor and outdoor units respectively. 3
-
Ⅲ Installation Instructions
-
3 Installation of the Indoor Unit
a. Requirements on the Installation Location 1) Ensure the hanger is strong enough to withstand the weight of the unit. 2) The drainage of the drain pipe is easy. 3) No obstacle is in the inlet/outlet and the air circulation is in good condition. 4) Ensure the installation space shown in Fig.2 is…
-
② . If there is an opening in the ceiling, it is better to reinforce it to keep it flat and prevent it vibrating. Consult the user and builder for more details. ③ . If the strength of the ceiling is not strong enough, a beam made of angle iron can be used and then fix the unit on it. ④ . If the…
-
Fig.8 No. Name No. Name 1 Hanger 6 Transition Duct 2 Return Air Duct 7 Air Supply Duct 3 Canvas Duct 8 Diffuser 4 Return Air Louver 9 Diffuser Joint 5 Air Supply Outlet Table 3 c. Installation Steps of the Round Air Supply Duct 1) Preinstall the outlet of the round duct on the transition duct and…
-
Table 4 Dimensions of the Air Supply Outlet and Return Air Inlet (unit: mm)
Air Supply Outlet Return Air Inlet A B C D 1062 980 162 Item Model MC-D09AI MC-D12AI MC-D18AI MC-D21AI MC-D24AI 7 Installation of the Return Air Duct a. The default installation location of the rectangular flange is in the back and the return air cover plate is in the bottom, as shown in Fig.11.…
-
8 Installation of the Condensate Pipe
a. The condensate pipe should keep a inclination angle of 5~10° , which can facilitate the drainage of the condensate water. And the joints of the condensate pipe should be insulated by the insulation material to prevent condensing(see Fig.13). Insulating Layer for the Condensate Pipe Pipe Lid…
-
(Right) with a min. degree of slope 1/100
(Wrong) Fig.14 e. Insert the drain hose into the drain hole and tighten it with clamps. f. Wrap the clamps with large amount of sponge for thermal insulation. g. The drain hose inside the room also should be insulated. Clamp (accessory) Sponge (accessory) Clamp (accessory) Sponge (gray)D rain Hose…
-
I - Joint of drain pipe
Drain Hose (accessory) Max.75mm Max.1000mm The specification of the joint of the drain pipe should be suitable to the running capacity of the unit Fig.17 12 Test for the Drainage System a. After the electric installation, please take a test for the drainage system. b. During the test, check if the…
-
d. Wrap the exposed refrigerant pipe and the joints by sponge and then tighten them with the plastic tape. CUATION ! ① . During the connection of the indoor unit and the refrigerant pipe, never pull any joints of the indoor unit by force; otherwise the capillary pipe or other pipe may crack, which…
-
crimpling pliers
4) Let the screw go through the terminal of the multi-core wire and then fix it on the wiring board. Fig.20 WARNING! ① . If the power cord or the signal line is damaged, they must be replaced with the dedicated one. ② . Prior to the wiring, please check the voltage marked on the nameplate and then…
-
MC-E36AI
-
17 Wiring of the Signal Line of the Wired Controller
1) Open the cover of the electric box of the indoor unit. 2) Let the signal line go through the rubber ring. 3) Insert the signal line to the four-pin socket on the printed circuit board of the indoor unit. 4) Fix the signal line with the binding wire. 18 Electric Installation Table 7 Indoor Unit…
-
Rated Working Conditions
Ⅳ Rated Working Conditions Table 8 Working Temperature Range Indoor side state Outdoor side stae Dry bulb temp. ℃ Wet bulb temp. ℃ Dry bulb temp. ℃ Wet bulb temp. ℃ Rated Cooling Max. cooling Min. cooling — Rated Heating Max. heating 27 — 24 18 Min. heating 20 15 - 15 - 16 16
-
Error Analysis
Ⅴ Error Analysis If your conditioning unit runs abnormally, please check the following items before contact the maintenance serviceman. Table 9 Errors Failed startup Possible Causes There is no power supply. The breaker opens owing to electrical leakage. Voltage is too low. Stop after a short while…
-
Maintenance
Ⅵ Maintenance CAUTION! Take notice of the following items before clean your air conditioning unit. ① . Cut off the main power supply before contact any wiring device. ② . Only when the unit is turn off and the main power supply is cut off, can the unit be cleaned; otherwise it would cause an…