Инструкция на Арматура для систем водоснабжения Oventrop
Технические данные арматуры Aquastrom UP-F, UP-KFR, UP-Therm
Смотрите также: Основной документ →
Загружаем документ…
Текст инструкции
-
Technical information
Tender specification: The Oventrop flush-mounted valves “Aquastrom” are straight pattern valves without dead zone for use in potable water systems. Depending on the valve insert, they are used as free-flow valve according to EN1213, as combination free-flow valve / non-return check valve according…
-
Flush mounting
Now fit clamping bonnet (pos. 5) into the flush-mounting pipe (pos. 2) so that the cogs and the toothed spindle (pos. 3) engage. Tighten clamping bonnet in the flush-mounting pipe by turning nut A (16 mm) clockwise whilst holding still nut B (22 mm). SW 22 (B) SW 16 (A) After installation into the…
-
Front of wall installation
For installation according to the dry-build system, Oventrop offers the mounting set, item no. 422 90 20. When used in humid locations (shower, bathroom etc.), the bonded liner (pos. 7) must be placed into the tile adhesive or the wall paper paste after having fixed the valve onto the front of wall…
-
Explanations
The pipes are to be flushed thoroughly before initial operation (DIN 1988 part 2 §11.2). The national regulations are to be observed! A potable water circulation system can be calculated using the Oventrop programme OV-Plan which can be found on the Oventrop CD (available free of charge). Note…