Инструкция на Коммерческие тепловые насосы прямого нагрева MDV серии RSJ: наружные блоки RSJ-420/SZN1-H. Руководство по установке.
Смотрите также: Полное техническое руководство →
Загружаем документ…
Текст инструкции
-
COMMERCIAL HEAT PUMP
INSTALLATION AND OPERATION INSTRUCTIONS Applicable model RSJ-420/SZN1-H Please read this manual carefully before use and keep it properly. The cover effect drawing is for reference only, and the specific model is subject to the real object.
-
The installation height of power supply should be over 1.8m, if
there is any water spattered, separate the power supply from water. A one-way valve must be installed on the water inlet side, which is available from accessories, see manual "accessories" part. After a long term use, check the unit base and fittings. If damaged, the unit may sink and result in…
-
3. 2 Dimensions(Unit: mm)
884 1015 1026 Fig 3.2 3.3 Distance of ground screws (Unit: mm) 881 788 ≥1400 Unit 1 788 Unit 2 Through-hole (15 round holes) Fig 3.3 Installation & Owner's Manual 3
-
3.4 Water pipe joint specifications
Table 3-1 Model Water inlet pipe joint Water outlet pipe joint RSJ-420/SZN1-H DN32 DN32 Remarks Flanged joint 4. UNIT INSTALLATION 1) Ensure there’s enough air flow to supply the heat exchager. Take influence of down draft caused by tall buildings around the unit to air dischage into consideration…
-
4.5 Pipeline connection
CAUTION Walls around the unit should not higher than 1m calculating from the bottom of unit. A baffle should be installed to the top of the unit to keep the unit from rains and snows, the distance between the top of the unit and the baffle should be more than 2m When multiple units are installed…
-
Heat pump
Heat pump water heater water heater 0# unit inlet outlet …… …… Hot water inlet sent to the user Hot water outlet 3# unit To drain ditch To drain ditch T5 tank sensor Circulation water port Water inlet Tap water A maximum of 4 heat pump water heaters can be connected in parallel Fig.4.3 Heat pump Hot…
-
5. INSTALLATION OF FITTINGS
Rated flow when the unit is circulative heating Table 5-1 5.1 Installing the water tank. The water tank temperature sensor can not be placed in the water directly, the water tank must be installed temperature pipe, and the water tank temperature sensor should be installed in the temperature pipe.…
-
6. ELECTRIC CONNECTION OF THE UNIT
6.3 Specifications of controlling wire Table 6-3 Name Qty. Size(UL1015) Only use the electric components specified by our company, and require installation and technical services from the manufacturer or authorized dealer. E-heater control wire\ Circulating water pump control wire\ Remote alarm…
-
Remote Electric auxiliary heater alarm Circulating pump Passive switch signal output only, can’t drive the device directly A B Wire controller power supply P Q E Communicate with wire controller and other units Please use shield wire to connect and connect shield terminal to S1 White White Black…
-
Pay attention to the power phase sequence, if wrong connect the phase sequence, the compressor not operate, and the digital tube of the water heater electrical control panel will display error code. Change the phase sequence, and powering again until the nixie tube doesn’t display error and…
-
6.8 Electrical control schematic diagram
Fig 6.5 Parts names Fig 6.5 Installation & Owner's Manual 11
-
Table 6-5
No. Detailed specification 0 Communication port for other unit (Error code E2) 1 Communication port for wire controller (Error code E2) 2 System low pressure protection (Protection code P0) 3 System high pressure protection (Protection code P1) 4 E-heat temp. sensor connector of…
-
Table 6-6
Detailed specification No. 11 15 Left side: CHECK, spot check key, for checking the operating state of unit Right side: FORCE, constraint key, special function for constraint exit 16 Display digital pipe 17 3-phase 4-wire system power input (Error code E1) Note: No phase and wrong phase of power…
-
7. TRIAL RUN
7.1 Check item table prior to trial run CAUTION Table 7-1 No. Item Enter “Debugging replenishing” method: Remark Long press “CHECK” button for 3s, then the digital pipe will display “0” and be flashed with 2Hz frequency, means enter to the function selection state; 1 Whether the unit is installed…
-
8. FAULT ANALYSIS AND SOLUTIONS
8.1 Fault analysis and solutions Before asking for serving or repairing, check the following points: Table 8-1 CAUSE PHENOMENA Please check that again Not distribute to malfunction White aerosol or globule is give out. Make sound of “hiss” every now and then. 15 14 When the unit is defrosting, the…
-
If has the following error, please call your service agent
Error Possible reason Table 8-2 Detect and settle measure 1. Power error 2. Wire connection is loosen 3. Relay or fuse error 4. Compressor error 1. Connected with wrong phase sequence 2. Check and fasten again 3. Chec and repair 4. Change the compressor Fan has loud noise 1. Fixing screw of the fan…
-
8.2 Failure of wired controller and its reason
8.2.1 Failure information and code In case the unit runs under abnormal condition, failure protection code will display on both digital screen of PCB and wired controller, and the indicator on the wired controller will flash with 5Hz. The display codes are shown in the following table: Table 8-3 No.…
-
Continuous come out any error for 4 times within 2 hours, then the unit will stop running. At the same time, it will be counted as once. After 1 hour, the unit will be automatically running again. If the stop frequency reaches 5 times, the protection code will be displayed and the unit should be…
-
9. MAINTENANCE
Table 9-1 1) All the safety protection devices in the unit will be set before leaving the factory, the user can not adjust or remove them, in case to damage the unit. PH Value Total Hardness 2) First on the unit or cut-off the power for a long-term stop (more than 1 day) and then re-power on, it…
-
10. SPECIFICATIONS
Table 10-1 Model RSJ-420/SZN1-H Heating capacity (kW) 39 Nominal input power (kW) 9.65 Rated Input(kW) 14.5 Nominal input current(A) 19.7 Nominal water output(m3/h) 0.85 Circulating heating rated water flow(m3/h) 6.9 Water resistance in circulative rated water flow(kPa) 160 Rated input power(kW)…
-