Инструкции на Инверторные мульти сплит-системы MDV (сервис мануалы)
Инверторные мульти сплит-системы серии R. Сервис мануал.
Смотрите также: Коды ошибок: 20 кодов →
Загружаем документ…
Текст инструкции
-
RMI-1103-A
SERVICE MANUAL MIDEA AIRCONDITIONER EUROPE MARKET DC INVERTER MULTI TYPE R DC INVERTER MULTI SERIES
-
2. Function
2.1 Model Names of Indoor units DC Capacity Indoor units 7k MDSRI-07HRDN1 9k MDSRI-09HRDN1 12k MDSRI-12HRDN1 18k MDSRI-18HRDN1 Inverter Multi Series 6
-
2.2 Product features
Indoor unit Operation by remote controller Sensing by temperature sensor Room temperature control Maintain the room temperature in accordance with the setting temperature. Ionizer(optional) Anti-freezing control in cooling Time Delay Safety control Golden fin(optional) Indoor fan speed control high…
-
3. Dimension
Model W H D MDSRI-12HRDN1 MDSRI-18HRDN1 MDSRI-07HRDN1 MDSRI-09HRDN1 Position of installation board Model R(mm) L(mm) H(mm) Dimension of installation hole(mm) MDSRI-07HRDN1 111.5 100 45 φ65 MDSRI-09HRDN1 111.5 100 45 φ65 MDSRI-12HRDN1 83.5 100 45 φ65 MDSRI-18HRDN1 φ65
-
4. Wiring Diagram
MDSRI-07HRDN1 MDSRI-09HRDN1 MSRI-12HRDN1 MSRI-18HRDN1
-
5. Operation characteristics
Temperature Cooling operation Heating operation Drying operation Room temperature ≥17℃ ≤30℃ ≥17℃ Outdoor temperature 0℃~50℃ -15℃~24℃ 0℃~50℃ Mode CAUTION: 1. If the air conditioner is used beyond the above conditions, certain safety protection features may come into operation and cause the unit to…
-
6. Electronic function
6.1 Abbreviation T1: Indoor ambient temperature T2: Coil temperature of indoor heat exchanger middle. T2B: Coil temperature of indoor heat exchanger outlet. T3: Coil temperature of outdoor heat exchanger T4: Outdoor ambient temperature T5: Compressor discharge temperature Ts:Setting temp. 6.3 Main…
-
6.4 Operation Modes and Functions
6.4.1 Fan mode (1) The outdoor fan and compressor stop. (2)Temperature setting function is disabled, and no setting temperature is displayed. (3) Indoor fan can be set to high/med/low/auto. (4) The louver operates the same as in cooling mode. (5) Auto fan: The action of auto fan in fan-only mode is…
-
6.4.2.2 Indoor fan running rules
In cooling mode, indoor fan runs all the time and the speed can be selected as high, medium, low and auto. Auto fan in cooling mode acts as follow: 3.5 High 3 Medium 1.5 1 Low 6.4.2.3 Evaporator low temperature T2 protection. When T2<4℃, the indoor has no capacity demand and resume till T2>8℃.…
-
T2
44℃ 38℃ ℃ Setting 37℃ Low 34℃ 33℃ Breeze 24℃ 17℃ Super Breeze Off Auto fan action in heating mode. Low 2.5 2 Medium 1.5 1 High 6.4.3.3 Outdoor fan running rules: 14 Low 12 High 6.4.3.3 High evaporator coil temp.T2 protection: If T2>63℃, the indoor unit has no capacity demand and resume till 48℃.…
-
HEAT_F2
COOL_F9 Compressor 10S 30S 30S 10S 4-Way valve Outdoor fan Indoor fan 10S Condition of ending defrosting: If any one of following items is satisfied, defrosting will stop and the machine will turn to normal heating mode. ① T3 >TCDE; TCDE=15℃. ② The defrosting time achieves 10min. 6.4.4 Auto-mode…
-
in cooling mode
6.4.5.2 Overlow room temperature protection In drying mode, if room temperature is lower than 10℃, the indoor fan will stop and not resume until room temperature exceeds 12℃. 6.4.5.3 Evaporator anti-freezing protection are active 6.4.6 Forced operation function 6.4.6.1 Enter forced operation…
-
6.4.7 Timer function
6.4.7.1 Timing range is 24 hours. 6.4.7.2 Timer on. The machine will turn on automatically when reaching the setting time. 6.4.7.3 Timer off. The machine will turn off automatically when reaching the setting time. 6.4.7.4 Timer on/off. The machine will turn on automatically when reaching the setting…
-
and turn to auto mode as 24℃ setting temp
6.4.11 Mode conflict The indoor units can not work cooling mode and heating at same time. Heating mode has a priority. 6.4.11.1 Definition: Cooling mode Heating Mode Fan Off Cooling mode No Yes No No Heating Mode Yes No Yes No Fan No Yes No No Off No No No No No: No mode conflict; Yes: Mode conflict…
Схемы, таблицы и рисунки — в просмотре документа выше. Клик по номеру страницы открывает её в просмотре.
Другие файлы документа
- Внутренние блоки кассетного типа серии Free Match MDCA2I-07/09/12/18HRDN1 (R410A 220~240V‐1Ph‐50Hz). Сервис мануал.PDF · 876.21 Kb
- Наружные блоки серии Free Match MD2O-14HDN1, MD2O-18HDN1, MD3O-21HDN1, MD3O-27HDN1, MD4O-36HDN1, MD5O-36HDN1. Полное техническое руководство.PDF · 2.09 Mb
- Внутренние блоки серии Free Match (Aurora 3D Inverter Series) MDSAI-07HRFN1, MDSAI-09HRFN1, MDSAI-12HRFN1, MDSAI-18HRFN1. Сервис мануал.PDF · 1.30 Mb
- Внутренние блоки канального типа MDTBI. Сервис мануал.PDF · 292.03 Kb
- Внутренние блоки кассетного типа MDCA2I-07HRDN1, MDCA2I-09HRDN1, MDCA2I-12HRDN1, MDCA2I-18HRDN1. Сервис мануал.PDF · 294.07 Kb
- Внутренние блоки MDFFI-07HRDN1, MDFF-09HRDN1, MDFF-12HRDN1. Сервис мануал.PDF · 289.63 Kb
- Внутренние блоки настенного типа серии R: MDSRI-07HRDN1, MDSRI-09HRDN1, MDSRI-12HRDN1, MDSRI-18HRDN1. Сервис мануал.PDF · 303.50 Kb
- Мульти сплит-системы MD2O-14HDN1, MD2O-18HDN1, MD3O-21HDN1, MD3O-27HDN1, MD5O-36HDN1, MD4O-36HDN1. Сервис мануал.PDF · 797.45 Kb
- Наружные и внутренние блоки мульти сплит-системы. Коды ошибок.PDF · 1.53 Mb