E 2002 Lennox Industries Inc. Dallas, Texas, USA 504,571M 1/2002 G60UH(X) SERIES GAS FURNACE Litho U.S.A. WARNING If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use gasoline or other…
-
DURALOKTM HEAT EXCHANGER ASSEMBLY TOP CAP COMBUSTION AIR PROVING (PRESSURE) SWITCH FLUE COLLAR CABINET COMBUSTION AIR INDUCER GAS VALVE UPPER ACCESS PANEL GAS MANIFOLD BURNERS TWO-STAGE, SURELIGHTt INTEGRATED CONTROL BOARD BLOWER MOTOR BLOWER ACCESS PANEL CONTROL BOX FIGURE 1 WARNING WARNING Product…
-
Your furnace is a gas appliance. It is critical that the gas
WARNING supplied to the unit be completely burned to avoid the proĆ Do not use this furnace if any part has been under water. Immediately call a qualified service technician to inspect the furnace and to replace any part of the control system and any gas control which has been under water. IMPORTANT…
-
gas control knob or lever. Use only your hand to turn the gas control knob or push the gas lever. Never use tools. If the knob or lever will not move by hand, do not try to repair it. Call a qualified service technician. Force or attempted repair may result in a fire or explosion. WHITE RODGERS 36E…
-
Burner Flame
Filters This unit is not equipped with a filter or rack. A field-proĆ vided, high-velocity filter is required to ensure proper unit operation. A filter must be in place any time the unit is operating. CAUTION To ensure proper operation, a qualified technician should annually check the burner flame.…
-
Planned Service
You should expect a service technician to check the followĆ ing items during an annual inspection. Power to the unit must be shut off for the service technician's safety. Fresh air grilles and louvers (on the unit and in the room where the furnace is installed) - Must be open and unobĆ structed to…