HS29
Corp. 9715−L9 Service Literature HS29 SERIES UNITS The HS29 is a residential split-system condensing unit. Condensing coil size, circuiting and air volume result in a minimum SEER rating of 10.0. The series is designed for use with an expansion valve or RFCIV system in the indoor unit. However, the…
-
SPECIFICATIONS (contd.)
-
ELECTRICAL DATA
Model No. HS29-141 HS29-211 HS29-261 HS29-311 HS29-411 208/230v 1ph 208/230v 1ph 208/230v 1ph 208/230v 1ph 208/230v 1ph 208/230v 3ph 460v 3ph Rated load amps 4.9 8.6 10.1 11.8 17.5 10.3 4.3 Power factor .97 .97 .96 .92 .90 .83 .83 Locked rotor amps 26.3 48.3 60.0 69.4 96.0 75.0 40.0 Full load amps…
-
ELECTRICAL DATA
Model No. HS29-042 HS29-048 HS29-060 Rated load amps 208/230v 1ph 18.6 208/230v 1ph 23.7 208/230v 1ph 28.8 Line voltage data 60 hz Compressor Power factor .84 .98 .95 Locked rotor amps 127.0 129.0 169.0 Full load amps 1.1 1.9 1.9 Locked rotor amps 1.9 4.1 4.1 Rec. maximum fuse or circuit breaker…
-
TABLE 1
I − UNIT INFORMATION HS29 condensing units are available in 1, 1 -1/2, 2, 2 -1/2, 3, 3 -1/2, 4 and 5 ton capacities. All major components (indoor blower/coil) must be matched according to Lennox recommendations for the compressor to be covered under warranty. Refer to the Engineering Handbook for…
-
5 − Fan Capacitor C1
The fans in three-phase HS29−413, −463, −513, −653, −683, units use permanent split capacitor motors. A single capacitor C1 is used for the fan motor. The capacitor is located inside the unit control box (see figure 1). Table 3 shows the ratings of C1. TABLE 3 HS29 FAN CAPACITOR RATING (C1) HS29…
-
Three-Phase Compressor Rotation
2 − Compressor Cover (Figure 5) Three-phase scroll compressors must be phased sequentially to ensure correct compressor rotation and operation. At compressor start-up, a rise in discharge and drop in suction pressures indicates proper compressor phasing and operation. If discharge and suction…
-
III − REFRIGERANT SYSTEM
A − Plumbing B − Service Valves Field refrigerant piping consists of liquid and suction lines from the condensing unit (sweat connections) to the indoor evaporator coil (flare or sweat connections). Use Lennox L10 (flare) or L15 (sweat, non−flare) series line sets as shown in table 6 or table 7 or…
-
SUCTION LINE SERVICE VALVE (VALVE OPEN)
LIQUID LINE SERVICE VALVE (VALVE OPEN) INSERT HEX WRENCH HERE INSERT HEX WRENCH HERE STEM CAP STEM CAP INLET FROM INDOOR COIL SERVICE PORT INLET FROM COMPRESSOR SCHRADER VALVE OUTLET TO COMPRESSOR SERVIC E PORT CAP SERVICE PORT CAP OUTLET TO INDOOR COIL SCHRADER VALVE SERVICE PORT LIQUID LINE…
-
IV − CHARGING
The unit is factory−charged with the amount of HCFC−22 refrigerant indicated on the unit rating plate. This charge is based on a matching indoor coil and outdoor coil with a 20 foot (6.1 m) line set. For varying lengths of line set, refer to table 8 for refrigerant charge adjustment. A blank space…
-
D − Charging
If the system is completely void of refrigerant, the recommended and most accurate method of charging is to weigh the refrigerant into the unit according to the total amount shown on the unit nameplate. Also refer to the SPECIFICATIONS tables on pages 1 and 2. If weighing facilities are not…
-
2 − RFCIV Systems
E − Oil Charge Refer to table 4 on page 6 and table 5 on page 7. The following procedures are intended as a general guide for use with RFCIV systems only. For best results, indoor temperV − MAINTENANCE ature should be between 70°F and 80°F (21.1°C and 26.7°C). At the beginning of each heating or…
-
TABLE 11
NORMAL OPERATING PRESSURES* HS29−012 HS29−018 HS29−024 HS29−030 HS29−036 HS29−042 OUTDOOR ENTERING AIR TEMPERATURE _F (_C) HS29−048 HS29−060 LIQ. +1 0 PSIG SUC. +1 0 PSIG LIQ. +1 0 PSIG SUC. +1 0 PSIG LIQ. +1 0 PSIG SUC. +1 0 PSIG LIQ. +1 0 PSIG SUC. +1 0 PSIG LIQ. +1 0 PSIG SUC. +1 0 PSIG LIQ. +1 0…
-
VI − WIRING DIAGRAMS AND SEQUENCE OF OPERATION
HS29 SINGLE-PHASE OPERATING SEQUENCE (RECIPROCATING OR ROTARY COMPRESSOR) A−HS29 P" Voltage Operation Sequence This is the sequence of operation for HS29−461/511/651 and HS29−012/018/024 P" voltage units. The HS29−141/211/261/311/411/681 P" voltage units are similar; however, these units are not…
-
HS29 THREE-PHASE OPERATING SEQUENCE
(ALL COMPRESSORS) A−HS29 Y", G", and J" Voltage Operation Sequence This is the sequence of operation for HS29 Y" voltage units. The HS29 G"voltage sequence is the same; however the J" voltage units have an outdoor fan transformer. The sequence is outlined by numbered steps which correspond to…
-
HS29 SINGLE−PHASE OPERATING SEQUENCE
(SCROLL COMPRESSORS) A−HS29 P" Voltage Operation Sequence This is the sequence of operation for HS29−030/036/042/048/060 P" voltage units. The sequence is outlined by numbered steps which correspond to circled numbers on the adjacent diagram. NOTE− The thermostat used may be electromechanical or…