User manual
ADALINK Providing indoor climate comfort ADALINK-IOM-0907-E
-
ADALINK
INSTALLATION OPERATING & MAINTENANCE MANUAL Ref : AD ALINK_IOM-0907-E LENNOX have been providing environmental solutions since 1895, our r ange of Baltic TM rooftop continues to meet the standards that h ave mad e LENNOX a household nam e. Flexib le d esign solutions to meet YOUR needs and…
-
1. INTRODUCTION
You must read and be familiarized w ith this instruction manual before the start-up of the ADALINK. You must apply the follow ing instructions. We lay stress on the importance of training for a proper use of the Adalink. This Instruction manual must stay close to the Adalink Box. The Adalink is a…
-
Housing 1.3. Front panel control LED Installation - Operation - Maintenance manual (IOM) • ADALINK – 0907-E •4•
-
Connections 1.4.1.Power supply Pinout: 1.4.2.Ethernet The Adalink can be accessed by a 10/100BaseTX Ethernet connection. This connection can be made with two different cables (straight or crossed). These cables have 8 copper conductors and are known as UTP Class 5 with RJ45 terminations at both…
-
When cabling over long distance, you have to take care of the twisted pairs. This means that along with the above cabling conventions, the emission (TX+/TX-) and reception (RX+/RX-) signals have to be connected on the same twisted pair: Pins 4, 5, 7 and 8 do not have to be connected. The following…
-
1.4.5. PTSN Phone line connector
Pinout PST line Pin N° Description TIP 4 RING 5 6 Table 16: Pinout PST Line Installation - Operation - Maintenance manual (IOM) • ADALINK – 0907-E •7•
-
1.4.6.Serial Port
Type Female DB9 with 4/40 blocking screws Pinout serial port (according to mode): Pin N° RS485 A+ 4 5 GND B9 Table 15: Pinout serial port Installation - Operation - Maintenance manual (IOM) • ADALINK – 0907-E •8•
-
1.4.7.Configurable serial port
The configuration of the physical serial mode is done by a set of 4 dip switches located on left side from the unit. The settings of the switches are shown in the table below (note: switch 1 is the most right one). Note: the 3 sw itch configurations show n here abov e are the sole configurations…
-
Internet Explorer / Flash player / Java set up To be sure to be able to run Adalink from your Internet Explorer you need a Java and Flash Player add-on. You need to download this add-on from the CD. And of course to install the software. 2.3. Start up To do the start up of the Adalink, you need to…
-
and open the local area connections and configure it
Installation - Operation - Maintenance manual (IOM) • ADALINK – 0907-E • 11 •
-
You close all the windows by ok and open internet explorer
Installation - Operation - Maintenance manual (IOM) • ADALINK – 0907-E • 12 •
-
insert the Adalink address and enter to connect
You open the Adalink page 2.4. Customer network connection If the Adalink is not directly connected to a PC but connected on the customer network, you need to change the IP address, you need also to scan the IP address, the software EwonCfg.exe, available to download on Lennoxtools. For this…
-
when you scan the network, the software will automatically, recognize the ewon
You close all the windows by ok and open internet explorer: 2.5. Connection to the phone line or GSM 2.5.1.Under Windows 98, NT and 2000 1 ) Open the root folder Dial-up Networking. 2 ) Click on the icon Make new connection. 3 ) Give a name to this connection. 4 ) Select a local modem from the list…
-
6 ) Introduce the phone number of the Adalink and click Next
7 ) Click Finish. 8 ) The connection windows opens and introduce the PPP authentication parameters that are the same than those used to access to the Adalink embedded Web site (<adm> / < ada01LNX > by default). 9 ) The new connection has now been added in the “Connections” directory and also under…
-
Open the USR folder
2.6.1.Languages Files In standard Adalink is delivered with English an French language, if you want a different one, please ask the Lennox Technical Support for a xml translation file. When you have this file copy it in the language directory and delete the French one; List_fr.xml (Adalink can…
-
2.6.2.Background image and customer Logo
Adalink give you the possibility to have on the Adalink background the logo of the customer and a picture of the site of the customer. First you have to download the logo and the background of the customer according the following rules : Logo : The size of the picture must be max h x l = 72 x 250…
-
On this page you can enter new 4 digits password. And don’t forget to valid to save your new password in the Adalink memory. If your password is valid you open the main page of the Adalink. 3.3. Note book On the main page, you have access to the note book page, it’s a page dedicated to the site.…
-
Configuration 3.4.1.Desktop Configuration Installation - Operation - Maintenance manual (IOM) • ADALINK – 0907-E • 19 •
-
If during the start up of the Adalink you have download a site picture, you can modify the background configuration in the Adalink main page. And from this page you choose what type of background you need: Customer background or no background Customer logo or LENNOX logo 3.4.2.Unit configuration…
-
First you need to declare the Area or group you want to create on your site
3.4.2.1. Rename Area These is 32 area preset , and you can change the name of the area using the modify window. After you need to create a new unit, give a name, affect the BM50 card number and a area. 3.4.2.2.New unit You need to exit the window by “valid” to save the data. Installation - Operation…
-
3.4.2.3.Modifiy the units
To modify an exiting units, put the mouse on the units and double click right, you open the modification screen, with the same parameters as the new unit screen + a delete button. 3.4.2.4.Auto Position You automatically position the units on a concentric network. 3.4.2.5.Manual position of the unit…
-
3.4.5. Date & Hour Modification
On your bus loop, you need to synchronize the clocks of the BM50 cards and the inner clock of the Adalink. To modify the date and hour you need to choose the number and modify with the up and down arrows; when everything is properly set, save you values. If you want your loop clock synchronized also…
-
Calendar A yearly calendar is included and reachable from the main page with the Calendar icon. On the calendar page, you have a full year and you can apply clicking on the day, one the 6 days you have set up on the days types page. For easy use you can, when you have completed a week, copy it…
-
Do not forget to sav e your schedule before exit this page
3.6. Macro command You can force at each moment a macro command to an area, you chose your area, the macro command you want to affect, the value and push the button “Send” Installation - Operation - Maintenance manual (IOM) • ADALINK – 0907-E • 25 •
-
4. Functioning
4.1. Remote control of the unit 4.1.1. Unit Page On the front page, if the mouse stay on the roof top icon, a pop up appear with summary information’s. When you click on the unit, you enter in the “unit “ page On the top of the page the top line shows, the name ot the card, the name of the unit, the…
-
On this page you have 3 type of icons
Grey : unit parameter Blue : unit components Orange : temperatures The first grey icon is the mode information, it display the status of the unit: Cooling Heating Dead zone From this screen you have access to the list of the connected units by a right click on the Unit Name : And you can…
-
4.1.2.Fault Icon
The icon “fault” display the fault if there is one and if you open you have all the details of the fault in clear. On all the Setting line with a pencil at the end, you can enter by clicking on the pencil and change a parameter Installation - Operation - Maintenance manual (IOM) • ADALINK – 0907-E •…
-
4.1.3.Schedule Icon
On the schedule icon, you have access to the week schedule of the CL50. And you can modify by a click on the pencil all the parameter. 4.1.4. Clock Icon The clock icon is to check the hour and date and to activate the automatic summer/winter hour change. To set up the clock of the Adalink, you need…
-
To change the date and the hour, you select the number and you adjust with the arrows on the side. Do not forget to valid before exit to save the modification. 4.1.5. Room Icon To have access to the room temperature settings you need to click on the “Room” icon. In this window, by clicking on the…
-
4.1.6. Fresh Air Icon
To set your fresh air you need to enter in the “fresh air” window and by a click on the pencil you can setup all your parameters. 4.2. Supervision of the unit 4.2.1.Filter control You can control the status of the filters with the filter presso stat icon: Installation - Operation - Maintenance…
-
On this screen you can see
The current pressure drop of the filter The minimum value for airflow alarm The minimum value for no filters alarm The maximum value for dirty f ilter alarm And you can change the Factory settings with the pencil icon; you obtain a new screen with minimum, factory setting and maximum value.…
-
4.2.2. Temperature curves
For the 3 temperature icons (Orange): Outdoor Air Room Supply Air If you click you open a screen with the temperature graph, by hour, day or month Or if you choose on the top of this screen “Values”, you open a screen with the detailed instantaneous temperature and setting. You can come back…
-
4.2.3. Supply fan icon
When you open the Supply fan screen, you have access to the On / Off of the unit, the supply fan status and setting, and the exhaust fan status and settings. Installation - Operation - Maintenance manual (IOM) • ADALINK – 0907-E • 34 •
-
4.2.4. Condensing fan icon
Opening, the condensing fan screen, you have access to all the status of the condensing fans and the parameters of the Defrost. 4.2.5. Compressor icon In the compressor screen, you see the data of all the compressors according the number in the units and you can modify parameters like rotation…
-
4.2.6. Economiser icon
When you open the Economiser screen, you have access to the status of the economizer and the settings for Minimum Fresh air, CO2 control, air flow calibration. 4.2.7.Heating Icon In the heating screen, you see the type of heating, the status of the different stages and the setting of the activation.…
-
4.2.7.2.Electrical heating
Unit screen: Installation - Operation - Maintenance manual (IOM) • ADALINK – 0907-E • 37 •
-
4.2.7.3.Hot water heating
Unit screen: Installation - Operation - Maintenance manual (IOM) • ADALINK – 0907-E • 38 •
-
таблицы и схемы — в просмотре
-
www.lennoxeurope.com
Due to Lennox’s ongoing commitment to quality, the Specifications, Ratings and Dimensions are subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service…