WAR
RNING - Rea ad and follo ow all instrructions in tthis owner’s manual and oon the equipment. Failuree to follow instructions can cause se evere injury and/or death.. WAR RNING – Sucction Entrapm ment Hazard. Suction in suction s outlets and/or suction n outlet covers which w are, dam maged, broken…
-
WARNING – Separation Hazard. Failure to follow safety and operation instructions could result in violent separation of pump and/or filter components. Strainer cover must be properly secured to pump housing with strainer cover lock ring. Before servicing pool and spa circulation system, filters…
-
Installation Instructions
Pump Location The PowerFlo LX™ and EP series pumps MUST be installed below the pool water line (see Figure to right). Self-priming PowerFlo II™ pumps may be installed up to four (4) feet above the pool water line. Install pump on a firm, level base or pad to meet all local and national codes. The…
-
Fittings
Fittings restrict flow. For better efficiency, use the fewest possible fittings. Avoid fittings that could cause an air trap. Electrical WARNING – Ground motor before connecting to electrical power supply. Failure to ground pump motor can cause serious or fatal electrical shock hazard. WARNING – Do…
-
New Installation – Start-Up & Operation
Prior to Start-Up Fill strainer housing with water to suction pipe level. NEVER operate the pump without water. Water acts as a coolant and lubricant for the mechanical shaft seal. WARNING – NEVER run pump dry. Running pump dry may damage seals, causing leakage and flooding. Fill strainer housing…
-
Start-Up for Winterized Equipment
1. Follow filter manufacturer's instructions for reactivation of the filter. 2. Inspect all electrical wiring for damage or deterioration over the shutdown period. Have a qualified serviceman repair/replace wiring as needed. 3. Securely mount pump to base. 4. Install all intake and output fittings…
-
Troubleshooting
Motor Will NOT Start – Check For: 1. Improper or loose wiring connections; open switches or relays; tripped circuit breakers, GFCI’s, or blown fuses. 2. Manually check rotation of motor shaft for free movement and lack of obstruction. (See steps 4 & 5 of “Shaft Seal Change Instructions” in this…
-
Noisy Pump – Check For
1. Air leak in suction piping causing rumbling in pump. 2. Cavitation due to restricted or undersized suction line or leak at any joint, low water level in pool, and unrestricted discharge return lines. Correct suction condition or throttle return lines, if practical. Holding hand over return…
-
Replacement Parts
-
HAYWARD® Pool Products Limited Warranty
To original purchasers of this equipment, Hayward Pool Products, Inc. warrants its products to be free from defects in materials and workmanship for a period of ONE (1) year from the date of purchase, when used in single family residential applications. The limited warranty excludes damage from…
-