P/N: IS3600
Rev. A OWNER’S MANUAL INSTALLATION, OPERATION, & PARTS TriStar™ 75/120 GPM Waterfall Pump Series The Hayward TriStar Waterfall Pump is specifically engineered for high volume waterfall, spillway, and negativeedge pool applications, where quiet and efficient delivery of water through low restriction…
-
_______________________ ______Page 2 of 15
IMPORTANT SAFETY INSTRUCTIONS Before installing or servicing this electrical equipment, turn power supply OFF. Basic safety precautions should always be followed, including the following: Failure to follow instructions may result in injury. This is the safetyalert symbol. When you see this symbol on…
-
WARNING – It is required that licensed electricians do all electrical wiring. Risk of
Electric Shock. Hazardous voltage can shock, burn, and cause death or serious property damage. To reduce the risk of electric shock, do NOT use an extension cord to connect unit to electric supply. Provide a properly located electrical receptacle. All electrical wiring MUST be in conformance with…
-
WARNING – Hazardous Pressure. Pool and spa water circulation systems operate under
hazardous pressure during startup, normal operation, and after pump shutoff. Stand clear of circulation system equipment during pump startup. Failure to follow safety and operation instructions could result in violent separation of the pump housing and cover due to pressure in the system, which…
-
Product Specifications
Pump Model SP36075EE SP36120EE “A” 13 7/8” 13 7/8” Installation Instructions WARNING – This product should be installed and serviced only by a qualified professional. Pump Location Locate the high volume waterfall pump as close to the waterfall, spillway, or negativeedge pool as possible and run…
-
Piping System Layout
The piping system should be designed such that the discharge of the waterfall, spillway, or cascade is no more than (10) feet above the surface of the water in the pool. Elevations higher than this will limit the amount of flow available from the waterfall pump. The following list shows how the…
-
Electrical (cont’d.)
Voltage Voltage at motor MUST NOT be more than 10% above or below motor name plate rated voltage, or motor may overheat, causing overload tripping and reduced component life. If voltage is less than 90% or more than 110% of rated voltage when motor is running at full load, consult power company.…
-
WARNING – All suction and discharge valves MUST be OPEN, as well as filter air relief
valve (if available) on filter, when starting the circulating pump system. Failure to do so could result in severe personal injury. Starting/Priming the Pump: Fill strainer housing with water to suction pipe level. If water leakage occurs from anywhere on the pump or filter, DO NOT start the pump.…
-
______________________________Page 9 of 15
Storage/Winterization WARNING – Separation Hazard. Do not purge the system with compressed air. Purging the system with compressed air can cause components to explode, with risk of severe injury or death to anyone nearby. Use only a low pressure (below 5 PSI), high volume blower when air purging the…
-
Page 10 of 15 Removing the Impeller (See Parts Diagram on page 11 of this manual for pump component locations.) 3. Remove the motor canopy by removing the two (2) screws and pulling the canopy away from the motor. 4. To prevent motor shaft from turning, carefully place a 7/16" openend wrench over…
-
_____________________________Page 11 of 15 Replacement Parts Parts Diagram Detail of motor canopy with screws. Parts Listing Ref. No. Part No. Description Ctn. Qty. 1 SPX3200UNKIT Union Connector Kit (Includes Union Nut, Union Connector, Union Gasket 2 ea.) 1 2 SPX3200UG Union Gasket 1 3 SPX3200A…
-
Page 12 of 15 Parts Listing (cont’d.) Ref. No. Part No. 12 Description Ctn. Qty. SPX3220C Impeller for 75 GPM with Impeller Screw 10 SPX3230CU Impeller for 120 GPM with Impeller Screw 10 13 SPX3200SA Shaft Seal Assembly 10 14 SPX3200T Housing ORing 10 15 SPX3200E Seal Plate 1 16 SPX3200Z211 Housing…
-
____________________Page 13 of 15
Troubleshooting Motor Will NOT Start – Check For: Make sure the terminal board connections agree with the wiring diagram on motor data plate label. Be sure motor is wired for available field supply voltage (see pump operating label). 1. Improper or loose wiring connections; open switches or relays;…
-
Page 14 of 15 Low Flow – Generally, Check For: (cont’d.) 2. Undersized pool piping. Solution: Correct piping size. 3. Plugged or restricted discharge line of filter, valve partially closed (high gauge reading). Solution: Sand filters – backwash as per manufacturer’s instructions; D.E. filters…
-
Page 15 of 15
HAYWARD® LIMITED WARRANTY This pump was inspected before shipment from our plant. To original purchasers of this pump, Hayward Pool Products, Inc., 620 Division Street, Elizabeth, New Jersey, warrants its products free from defects in materials and workmanship for a period of ONE (1) year from the…