OWNER’S MANUAL INSTALLATION, OPERATION & PARTS Super II™ Pump Series The Hayward Super II Pump is specifically engineered for the demanding requirements of today’s in-ground swimming pool/spa that is equipped with large capacity filters, heaters, and pool cleaning equipment. The Super II is a…
-
IMPORTANT SAFETY INSTRUCTIONS
Basic safety precautions should always be followed, including the following: Failure to follow instructions can cause severe injury and/or death. This is the safety-alert symbol. When you see this symbol on your equipment or in this manual, look for one of the following signal words and be alert to…
-
WARNING – Hazardous Pressure. Pool and spa water circulation systems operate under hazardous pressure during start up, normal operation, and after pump shut off. Stand clear of circulation system equipment during pump start up. Failure to follow safety and operation instructions could result in…
-
General Information
Introduction This manual contains information for the proper installation and operation of the Hayward Super II Pump Series. The instructions in this manual MUST be followed precisely. Failure to install according to defined instructions will void warranty. Product Benefits …
-
Pump Mounting
Install pump on a firm, level base or pad to meet all local and national codes. Fasten pump to base or pad with screws or bolts to further reduce vibration and stress on pipe or hose joints. The base MUST be solid, level, rigid, and vibration free. Pump mount must: Allow pump inlet height to be as…
-
Electrical
WARNING – Ground and bond motor before connecting to electrical power supply. Failure to ground and bond pump motor can cause serious or fatal electrical shock hazard. WARNING – Do NOT ground to a gas supply line. WARNING – To avoid dangerous or fatal electrical shock, turn OFF power to motor before…
-
Install a Ground Fault Circuit Interrupter (GFCI) in circuit; it will sense a short-circuit to ground and disconnect power before it becomes dangerous to pool users. For size of GFCI required and test procedures for GFCI, see manufacturer’s instructions. In case of a power outage, check GFCI for…
-
Pumps with single speed motors are self priming to 10 ft. and pumps with 2 speed motors are self priming to 10 ft. on high speed only. Turn on power and wait for pump to prime, which may take up to five (5) minutes. Priming time will depend on vertical length of suction lift and horizontal length of…
-
When servicing electrical equipment, basic safety precautions should always be observed including the following. Failure to follow instructions may result in injury. WARNING – To reduce risk of injury, do not permit children to use this product. A. B. Disconnect all electrical power service to pump…
-
15. Fasten assembly to pump/strainer housing using the six (6) 3/8”" x 2" housing cap screws. (Be sure housing gasket is in place, and replace if damaged). Tighten alternately and evenly. Replacement Parts Parts Diagram Parts Listing USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 10 of 16 Super II…
-
Troubleshooting
Motor Will NOT Start – Check For: Make sure the terminal board connections agree with the wiring diagram on motor data plate label. Be sure motor is wired for available field supply voltage. 1. Improper or loose wiring connections; open switches or relays; tripped circuit breakers, GFCI’s, or blown…
-
3. Plugged or restricted discharge line of filter, valve partially closed (high gauge reading)
Solution: Sand filters – backwash as per manufacturer’s instructions; D.E. filters – backwash as per manufacturer’s instructions; Cartridge filters – clean or replace cartridge. 4. Air leak in suction (bubbles issuing from return fittings). Solution: Re-tighten using Teflon tape. 5. Plugged…
-
HAYWARD® Pool Products Limited Warranty
To original purchasers of this equipment, Hayward Pool Products, Inc. warrants its products to be free from defects in materials and workmanship for a period of ONE (1) year from the date of purchase, when used in single family residential applications. The limited warranty excludes damage from…
-
THIS PAGE INTENTIONALLY LEFT BLANK
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 14 of 16 Super II Pump Series IS3000XAZ Rev. G
-
THIS PAGE INTENTIONALLY LEFT BLANK
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 15 of 16 Super II Pump Series IS3000XAZ Rev. G
-
DETACH HERE: Fill out bottom portion completely and mail within 10 days of purchase/installation or register online. Super II ™ Pump Series Warranty Card Registration Please Print Clearly: Years Pool has been in service First Name____________________ Last Name_________________________ Street…