Инструкция на Насосы для бассейнов с регулируемой скоростью Hayward серии Super Pump VS SP2603VSP
Насосы для бассейнов с регулируемой скоростью Hayward серии Super Pump VS SP2603VSP. Руководство пользователя.
Загружаем документ…
Текст инструкции
-
Super Pump® VS Owner’s Manual Model SP2603VSP Super Pump VS Variable Speed Pump Hayward’s Super Pump VS variable speed pump delivers incredible energy savings via its advanced hydraulic design combined with a totally enclosed, permanent magnet motor. Super Pump VS is easily installed either as a…
-
1. IMPORTANT SAFETY INSTRUCTIONS
Before installing or servicing this electrical equipment, turn power supply OFF. Basic safety precautions should always be followed, including the following: Failure to follow instructions may result in injury. This is the safety-alert symbol. When you see this symbol on your pump or in this manual…
-
WARNING – Pool and spa components (seals, gaskets, etc.) have a finite life. All components should be inspected frequently and replaced at least every ten years, or if found to be damaged, broken, cracked, missing, or not securely attached. WARNING – Risk of Electric Shock. All electrical wiring…
-
WARNING – To Reduce the risk of Entrapment Hazards
When outlets are small enough to be blocked by a person, a minimum of two functioning suction outlets per pump must be installed. Suction outlets in the same plane (i.e. floor or wall), must be installed a minimum of three feet (3’) [0.91 meter] apart, as measured from near point to near point. …
-
2. General Information
2.1. Introduction This manual contains information for the proper installation and operation of the Hayward Super Pump VS Variable Speed Pump. The instructions in this manual MUST be followed precisely. 2.2. Primary Features Totally enclosed, permanent magnet motor Advanced hydraulic…
-
3. Energy Efficiency Overview
The energy consumed by a pool pump is measured in terms of Watts (W) or Kilowatts (kW). The Super Pump VS Variable Speed Pump displays power consumption in Watts. Given this information, you can determine the cost of operating the pump: Power consumption of pump X Cost of electricity = Cost of Pump…
-
4.2. Pump Mounting
Install pump on a level concrete slab or other rigid base to meet all local and national codes. Secure pump to base with screws or bolts to further reduce vibration and stress on pipe or hose joints. The base must be level, rigid, and vibration free. Pump mount must: Allow pump inlet height to be…
-
4.5. Electrical
WARNING – All electrical wiring MUST conform to local codes, regulations, and the National Electric Code (NEC). WARNING – Ground and bond pump before connecting to electrical power supply. Failure to ground and bond pump can cause serious or fatal electrical shock hazard. Do NOT ground to a gas…
-
4.10. Remote Control Wiring/Operation
Super pump VS can be controlled in a wide variety of ways as described below: 1. Super Pump VS can operate by itself in Stand-Alone Mode using its built-in programmable timers. 2. Super Pump VS can also be controlled from third party controls (i.e. another manufacturer’s control) and Hayward…
-
4.12. Interface Wall Mounting
The interfa ace can also be b wall mountted using the parts supplied d in the optional wall moun nt kit using the following procedure e. 1. TURN OFF THE ELEC CTRICAL POWE ER AT THE CIR RCUIT BREAKE R. 2. Loose otor drive and en the two scre ews securing the user interrface to the mo d remove the u…
-
Fig
gure 4.12-2: Re emoving the Interface Mou unting Plate to o access the D Drive wiring co ompartment A the Bllank Cover Figure 4.12-3: Adding Page e 13 of 36 H GENUINE G REPLACEMENTT PARTS USE ONLY HAYWARD Super Pump P VS Pu ump IS2603V VSP Rev-A
-
Figure 4.12-4: Wall Mounting the Interface
4.13. Installation Procedure Please review sections 4.1 through 4.12 before continuing with this section. 1. TURN OFF THE ELECTRICAL POWER AT THE CIRCUIT BREAKER AND REMOVE THE USER INTERFACE. 2. Loosen the two screws securing the user interface to the motor drive and remove the user interface. …
-
5. Wiring Diagrams
5.1. Input Power Wiring (Required) Figure 5.1-1 DRIVE HIGH VOLTAGE CONNECTIONS 5.2. Wall Mounted Digital Control Interface Wiring (Optional) Figure 5.2-1 Connection wire must be rated for a minimum of 300V, and may be up to 500 feet in length. Use removable 4-position terminal block connectors for…
-
5.3. External Relay Speed Control Wiring (Optional, for remote selection of pump
speed) Note: For third party controls and Hayward controls that are NOT software compatible. Figure 5.3-1 Connection wire must be rated for a minimum of 300V. Inputs are rated to accept a low voltage supply of 18-30VAC (24VAC+/-20%) or 9-30VDC (12/24VDC +/-20%). The “+12V” and “COM” terminals may be…
-
5.4. Hayward Automation Control Wiring (Optional, for remote control of pump
speed) Note: For software compatible Hayward controls only. Existing user interface wiring connections must be removed from 4-position terminal block connector and must be covered/secured inside wiring compartments prior to making wiring connections shown below. Figure 5.4 1 The Super Pump VS pump…
-
5.5. Remote Stop Switch Wiring (Optional)
Figure 5.5-1 Connection wire must be rated for a minimum of 300V. Switch must be latching type; pump is stopped when circuit is closed. Inputs are rated to accept a low voltage supply of 18-30VAC (24VAC +/-20%) or 9-30VDC (12/24VDC +/-20%). The “+12V” and “COM” terminals may be used as a low voltage…
-
6.2. Starting/Priming the Pump
Refer to item #9 in section 6.6 for priming time selection. Fill strainer housing with water to suction pipe level. If water leakage occurs from anywhere on the pump or filter, DO NOT start the pump. If no leakage occurs, stand at least 10 feet from pump and/or filter and proceed with starting the…
-
6.3. User Interface Summary
Figure 6.3-1 1. Preset Speeds: Buttons labeled SPEED 1 thru SPEED 4 can be used to run the pump at a predetermined speed for a certain length of time. Preset Speed settings can be quickly updated using the + and - arrow buttons to change the speed and then pressing the > button to save the new speed…
-
6.4. Menu Outline
1. Configuration Menu (see section 6.6 for basic product configuration) a. Set Day and Time b. Speed Selection c. MAX Allowed Speed d. MIN Allowed Speed e. Prime Duration f. Remote Control Mode g. Low Temp Operation h. Low Temp Setting 2. Timer Menu (see section 6.7 to program the 8 speeds with…
-
6.6. Configuration Menu
Screen 1. Configuration Menu Locked 2. Configuration Menu press > to enter 3. Use + / - to adjust, > go to next item 4. Time: Th 1:27PM + change or > skip 5. Set Day and Time Thursday 1:27p 6. Speed Selection rpm 7. MAX allowed speed 3450 (600-3450rpm) 8. MIN allowed speed 600 (600-3450rpm) 9. Prime…
-
pump, system plumbing, or pool from freezing. If Low Temp Operation is disabled, the temperature setting screen is not shown. Buttons Used Screen Comments 13. Reset all parameters + for yes; > to skip +<> Use + to reset to factory default settings Use > to skip reset 14. Are you sure? + for yes…
-
6.8. Preset Speed Setup Menu
Screen 1. Speeds Menu Press > to enter 2. Speed 1 Name Speed 1 3. Speed 1 Duration 0:30 hours Buttons Used Comments <> Use > to enter Speeds Menu +<> Use to rename displayed speed Move to next menu item +<> Use to set duration of speed Move to next menu item Note: Each time a preset speed is…
-
Buttons
Used Comments 7. Power Usage 225W (1700W Max) Real-time display of pump power usage. 8. Drive Temperature 67ºC (110ºC Max) Real-time display of motor driver temperature. Event log Press + to view 9. +- Use + to view event log Note: For troubleshooting purposes, the Event Log will record the last…
-
6.12. Remote Stop
Screen 1. Remote Stop is engaged Note: The above message will be displayed when an installed remote stop switch is activated. For either model, the pump will remain stopped until the remote stop switch is deactivated. See section 5.5 for more detail. 7. Maintenance Clean strainer basket…
-
9. Shaft Seal Change Instructions
IMPORTANT SAFETY INSTRUCTIONS PLEASE READ AND FOLLOW ALL INSTRUCTIONS When servicing electrical equipment, basic safety precautions should always be observed including the following. Failure to follow instructions may result in injury. WARNING – To reduce risk of injury, do not permit children to…
-
9.6. Replacing the Motor Assembly
13. Slide the motor assembly, with the diffuser in place, into pump/strainer housing, being careful not to disturb the diffuser gasket. 14. Fasten assembly to pump/strainer housing using the four (4) 3/8" x 2" bolts. (Be sure housing gasket is in place, and lubricated. Replace if damaged). Tighten…
-
10.2. Parts Listing
Ref. No. Part No. Description Qty. 1 SPX1600PN Swivel Nut & Hand Knob 2 2 SPX1600D Strainer Cover 1 3 SPX1600S Strainer Cover Gasket 1 4 SPX1600M Basket 1 5 SPX1700FG Drain Plug with Gasket 2 6 SPX1600AA Pump / Strainer Housing With Gasket 1 7 SPX1600R Diffuser Gasket 1 8 SPX2600B Diffuser 1 9…
-
11. Troubleshooting
11.1. General Problems Motor Will NOT Start: 1. Make sure the terminal board connections agree with the wiring diagram on the pump data plate label. 2. Be sure the pump is wired for the available field supply voltage (230VAC). 3. Check for and correct any improper or loose wiring connections; open…
-
Noisy Pump: 1. Air leak in suction piping, cavitations caused by restricted or undersized suction line or leak at any joint, low water level in pool, and unrestricted discharge return lines. Correct the suction condition or throttle return lines, if practical. Holding your hand over the return…
-
11.2. Check System Messages
Code Troubleshooting Check System DC voltage too high Indicates that the DC bus voltage has risen above 400 VDC. Verify that line voltage is within 10% (207-253 VAC) of pump rated voltage at the terminal block. Check System DC voltage too low Indicates that the DC bus voltage has dropped below 230…
-
12. Warranty
13. Product Registration DATE OF INSTALLATION INITIAL PRESSURE GAUGE READING (CLEAN FILTER) PUMP MODEL *Retain this Warranty Certificate in a safe and convenient location for your records Page 33 of 36 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Super Pump VS Pump IS2603VSP Rev-A
-
THIS PAGE INTENTIONALLY LEFT BLANK
Page 34 of 36 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Super Pump VS Pump IS2603VSP Rev-A
-
THIS PAGE INTENTIONALLY LEFT BLANK
Page 35 of 36 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Super Pump VS Pump IS2603VSP Rev-A
-
FCC Compliance Statement
This device complies with part 15 of the FCC rules. Operation is subjected to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has…
Схемы, таблицы и рисунки — в просмотре документа выше. Клик по номеру страницы открывает её в просмотре.