Rev. C OWNER’S MANUAL INSTALLATION, OPERATION, & PARTS Max-Flo™ PUMP Series The Hayward Max-Flo™ is specifically engineered for the demanding requirements of today’s in-ground swimming pool/spa that is equipped with large capacity filters, heaters, and pool cleaning equipment. The Max-Flo™ is a…
-
IMPORTANT SAFETY INSTRUCTIONS
Basic safety precautions should always be followed, including the following: Failure to follow instructions can cause severe injury and/or death. This is the safety-alert symbol. When you see this symbol on your equipment or in this manual, look for one of the following signal words and be alert to…
-
WARNING – Hazardous Pressure. Pool and spa water circulation systems operate under hazardous pressure during start up, normal operation, and after pump shut off. Stand clear of circulation system equipment during pump start up. Failure to follow safety and operation instructions could result in…
-
General Information
Introduction This manual contains information for the proper installation and operation of the Hayward Max-Flo™ Series. The instructions in this manual MUST be followed precisely. Failure to install according to defined instructions will void warranty. Product Benefits Exclusive…
-
Allow adequate access for servicing pump and piping. Incorporate a straight portion of pipe prior to pump inlet no less than (5) pipe diameters in length. Pipe Sizing Chart MAXIMUM RECOMMENDED SYSTEM FLOW RATE BY PIPE SIZE Pipe Size Flow rate Water Velocity Pipe Size Flow rate Water Velocity…
-
Insure that the electrical supply available agrees with the motor’s voltage, phase, and cycle, and that the wire size is adequate for the HP (kW) rating and distance from the power source. NOTE - All electrical wiring MUST be performed by a licensed electrician, and MUST conform to local codes and…
-
Start-Up & Operation
WARNING – All suction and discharge valves MUST be OPEN, as well as filter air relief valve (if available) on filter, when starting the circulating pump system. Failure to do so could result in severe personal injury. Starting/Priming the Pump: Pumps with single speed motors are self priming to 8…
-
Storage/Winterization
WARNING – Separation Hazard. Do not purge the system with compressed air. Purging the system with compressed air can cause components to explode, with risk of severe injury or death to anyone nearby. Use only a low pressure (below 5 PSI), high volume blower when air purging the pump, filter, or…
-
Removing the Impeller (See Parts Diagram on page 10 of this manual for pump component locations.)
3. Remove the motor end cover by removing the two (2) screws or pry off the cap covering the motor shaft. Hex shaped caps must be twisted off. 4. To prevent motor shaft from turning, carefully slide a 7/16" open-end wrench between the capacitor and the centrifugal switch (the wrench fits over the…
-
Replacement Parts
-
Troubleshooting
Motor Will NOT Start – Check For: Make sure the terminal board connections agree with the wiring diagram on motor data plate label. Be sure motor is wired for available field supply voltage. 1. Improper or loose wiring connections; open switches or relays; tripped circuit breakers, GFCI’s, or blown…
-
3. Plugged or restricted discharge line of filter, valve partially closed (high gauge reading)
Solution: Sand filters – backwash as per manufacturer’s instructions; D.E. filters – backwash as per manufacturer’s instructions; Cartridge filters – clean or replace cartridge. 4. Air leak in suction (bubbles issuing from return fittings). Solution: Re-tighten using Teflon tape. 5. Plugged…
-
▲Retain this Warranty Certificate (upper portion) in a safe and convenient location for your records. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 13 of 16 Max-Flo™ PUMP Series IS2800X5 REVC Rev. C
-
THIS PAGE INTENTIONALLY LEFT BLANK
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 14 of 16 Max-Flo™ PUMP Series IS2800X5 REVC Rev. C
-
THIS PAGE INTENTIONALLY LEFT BLANK
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 15 of 16 Max-Flo™ PUMP Series IS2800X5 REVC Rev. C
-
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 16 of 16 Max-Flo™ PUMP Series IS2800X5 REVC Rev. C
Схемы, таблицы и рисунки — в просмотре документа выше. Клик по номеру страницы открывает её в просмотре.