MaxFlo VS™ 500 Owner’s Manual Model SP23510VSP MaxFlo VS 500 Variable Speed Pump Hayward’s MaxFlo VS 500 variable speed pump delivers incredible energy savings via its advanced hydraulic design combined with a totally enclosed, permanent magnet motor. The MaxFlo VS 500 pump is easily installed…
-
1. IMPORTANT SAFETY INSTRUCTIONS
Before installing or servicing this electrical equipment, turn power supply OFF. Basic safety precautions should always be followed, including the following: Failure to follow instructions may result in injury. This is the safety-alert symbol. When you see this symbol on your pump or in this manual…
-
WARNING – Pool and spa components (seals, gaskets, etc.) have a finite life. All components should be inspected frequently and replaced at least every ten years, or if found to be damaged, broken, cracked, missing, or not securely attached. WARNING – Risk of Electric Shock. All electrical wiring…
-
WARNING – To Reduce the risk of Entrapment Hazards
When outlets are small enough to be blocked by a person, a minimum of two functioning suction outlets per pump must be installed. Suction outlets in the same plane (i.e. floor or wall), must be installed a minimum of three feet (3’) [0.91 meter] apart, as measured from near point to near point. …
-
2. General Information
2.1. Introduction This manual contains information for the proper installation and operation of the Hayward MaxFlo VS 500 Variable Speed Pump. The instructions in this manual MUST be followed precisely. 2.2. Primary Features Totally enclosed, permanent magnet motor Advanced hydraulic…
-
Note the power consumption is greatly affected by the speed of the pump. Lowering the speed of the pump can drastically reduce the power that is consumed. Below are some of the major benefits of running the pump at lower speeds. Benefits of running at low speeds Save electricity and money …
-
4.3. Pipe Sizing Chart
MAXIMUM RECOMMENDED SYSTEM FLOW RATE BY PIPE SIZE Pipe Size in. [mm] Maximum Flow Rate GPM [LPM] Minimum Straight Pipe Length “L” in. [mm] * 1 ½” [50] 45 [170] 7 ½” [190] 2” [63] 80 [300] 10” [254] 2 ½” [75] 110 [415] 12 ½” [317] 3” [90] 160 [600] 15” [381] Note: It is recommended that a minimum…
-
4.6. Electrical Specs
1. Voltage: 115VAC, 60Hz, Single Phase 2. Amps: 0.4-10.5 3. Speed Range: 600-3450 rpm Use copper conductors only. For indoor & outdoor use. Connect pump to a 15 amp branch circuit in accordance with local codes, regulations, and the National Electric Code (NEC). A disconnecting means located at…
-
4.11. Digital Control Interface Orientation
The Digital Control Interface can be rotated to any of four desired positions after installation by loosening the two screws securing the user interface to the motor drive, lifting the user interface and rotating it to the desired position, and tightening the two screws in the new position. (Figure…
-
4.12. Interface Wall Mounting
The interface can also be wall mounted using the parts supplied in the optional wall mount kit using the following procedure. 1. TURN OFF THE ELECTRICAL POWER AT THE CIRCUIT BREAKER. 2. Loosen the two screws securing the user interface to the motor drive and remove the user interface. (Figure…
-
Figure 4.12-2: Removing the Interface Mounting Plate to access the Drive wiring compartment
Figure 4.12-3: Adding the Blank Cover Page 13 of 32 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS MaxFlo VS 500 Variable Speed Pump IS23510VSP Rev-C
-
Figure 4.12-4: Wall Mounting the Interface
4.13. Installation Procedure Please review sections 4.1 through 4.12 before continuing with this section. 1. TURN OFF THE ELECTRICAL POWER AT THE CIRCUIT BREAKER AND REMOVE THE USER INTERFACE. 2. Loosen the two screws securing the user interface to the motor drive and remove the user interface. …
-
5. Wiring Diagrams
5.1. Input Power Wiring (Required) Figure 5.1-1 DRIVE HIGH VOLTAGE CONNECTIONS 5.2. Wall Mounted Digital Control Interface Wiring (Optional) Figure 5.2-1 Connection wire must be rated for a minimum of 300V, and may be up to 500 feet in length. Use removable 4-position terminal block connectors for…
-
5.3. External Relay Speed Control Wiring (For remote selection of pump speed)
Note: For third party controls and Hayward controls that are NOT software compatible. Figure 5.3-1 Connection wire must be rated for a minimum of 300V. Inputs are rated to accept a low voltage supply of 18-30VAC (24VAC+/-20%) or 9-30VDC (12/24VDC +/-20%). The “+12V” and “COM” terminals may be used…
-
5.4. Remote Stop Switch Wiring (Optional)
Figure 5.4-1 Connection wire must be rated for a minimum of 300V. Switch must be latching type; pump is stopped when circuit is closed. Inputs are rated to accept a low voltage supply of 18-30VAC (24VAC +/-20%) or 9-30VDC (12/24VDC +/-20%). The “+12V” and “COM” terminals may be used as a low voltage…
-
6.2. Starting/Priming the Pump
Refer to item #9 in section 6.6 for priming time selection. Fill strainer housing with water to suction pipe level. If water leakage occurs from anywhere on the pump or filter, DO NOT start the pump. If no leakage occurs, stand at least 10 feet from pump and/or filter and proceed with starting the…
-
6.3. User Interface Summary
Figure 6.3-1 1. Preset Speeds: Buttons labeled SPEED 1 thru SPEED 4 can be used to run the pump at a predetermined speed for a certain length of time. Preset Speed settings can be quickly updated using the + and - arrow buttons to change the speed and then pressing the > button to save the new speed…
-
6.4. Menu Outline
1. Configuration Menu (see section 6.6 for basic product configuration) a. Set Day and Time b. Speed Selection c. MAX Allowed Speed d. MIN Allowed Speed e. Prime Duration f. Remote Control Mode g. Low Temp Operation h. Low Temp Setting 2. Timer Menu (see section 6.7 to program the 8 speeds with…
-
6.6. Configuration Menu
Screen 1. Configuration Menu Locked 2. Configuration Menu press > to enter 3. Use + / - to adjust, > go to next item 4. Time: Th 1:27PM + change or > skip 5. Set Day and Time Thursday 1:27p 6. Speed Selection rpm 7. MAX allowed speed 3450 (600-3450rpm) 8. MIN allowed speed 600 (600-3450rpm) 9. Prime…
-
pump, system plumbing, or pool from freezing. If Low Temp Operation is disabled, the temperature setting screen is not shown. Buttons Used Screen Comments 13. Reset all parameters + for yes; > to skip +<> Use + to reset to factory default settings Use > to skip reset 14. Are you sure? + for yes…
-
6.8. Preset Speed Setup Menu
Screen 1. Speeds Menu Press > to enter 2. Speed 1 Name Speed 1 3. Speed 1 Duration 0:30 hours Buttons Used Comments <> Use > to enter Speeds Menu +<> Use to rename displayed speed Move to next menu item +<> Use to set duration of speed Move to next menu item Note: Each time a preset speed is…
-
Buttons
Used Comments 7. Power Usage 225W (1700W Max) Real-time display of pump power usage. 8. Drive Temperature 67ºC (110ºC Max) Real-time display of motor driver temperature. Event log Press + to view 9. +- Use + to view event log Note: For troubleshooting purposes, the Event Log will record the last…
-
6.12. Remote Stop
Screen 1. Remote Stop is engaged Note: The above message will be displayed when an installed remote stop switch is activated. The pump will remain stopped until the remote stop switch is deactivated. See section 5.4 for more detail. 7. Maintenance Clean strainer basket regularly. Do NOT…
-
9. Shaft Seal Change Instructions
IMPORTANT SAFETY INSTRUCTIONS PLEASE READ AND FOLLOW ALL INSTRUCTIONS When servicing electrical equipment, basic safety precautions should always be observed including the following. Failure to follow instructions may result in injury. WARNING – To reduce risk of injury, do not permit children to…
-
Replacing the Motor Assembly 13. Slide the motor assembly, with the diffuser in place, into pump/strainer housing, being careful not to disturb the diffuser gasket. 14. Fasten assembly to pump/strainer housing using the four (4) 5/16" x 1.75" bolts. (Be sure housing gasket is in place, and…
-
10.2. Parts Listing
Ref. No. Part No. Description Qty. 1A SPX2300DLS Strainer Cover Kit (Includes Strainer Cover, Lock-Ring, O-Ring) 1 1B SPX2300DLSB Strainer Cover Kit for Biguanide Sanitizers (Includes Strainer Cover, Lock-Ring, O-Ring) NOT Pressure Testable 1 2 SPX2300Z4 Strainer Cover O-Ring 1 3 SPX2300M Strainer…
-
Motor Hums, But Does NOT Start: 1. Impeller jammed with debris. Have a qualified repair professional open the pump and remove the debris. Pump Won't Prime: 1. Empty pump/strainer housing. Make sure the pump/strainer housing is filled with water and the cover o-ring is clean. Ensure the o-ring is…
-
11.2. Check System Messages
Code Troubleshooting Check System DC voltage too high Indicates that the DC bus voltage is too high. Verify that line voltage is within 10% (104-126 VAC) of pump rated voltage at the terminal block. Check System DC voltage too low Indicates that the DC bus voltage is too low. Verify that line…
-
13. Warranty
Page 31 of 32 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS MaxFlo VS 500 Variable Speed Pump IS23510VSP Rev-C
-
FCC Compliance Statement
This device complies with part 15 of the FCC rules. Operation is subjected to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has…