Инструкция на Сплит-кондиционеры кассетные. Сервисное руководство.
AUY 12, 14 FBAB/UBAB. Сплит-кондиционеры кассетные. Сервисное руководство.
Смотрите также: Сервисное руководство →
Загружаем документ…
Текст инструкции
-
SPLIT TYPE
AIR CONDITIONER CASSETTE type (50Hz) Models Indoor unit Outdoor unit AUY12FBAB AUY12UBAB AUY14FBAB AUY14UBAB AOY12FSAJ AOY12USAJL AOY14FSDJ AOY14USDJL CONTENTS SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 OUTLINE AND DIMENSIONS . . . . . . . . . .…
-
TYPE INDOOR UNIT OUTDOOR UNIT COOL COOL & HEAT AUY12FBAB AUY12UBAB AOY12FSAJ AOY12USAJL COOLING CAPACITY (kW) 3.60 3.55 HEATING CAPACITY (kW) 4.00 ELECTRICAL DATA POWER SOURCE (V) 230 FREQUENCY (Hz) 50 RUNNING CURRENT INPUT WATTS E.E.R. (A) (kW) (kW/kW) COOLING 5.5 5.5 HEATING 5.4 COOLING 1.24 1.24…
-
AUY12FBAB
AUY12UBAB AOY12FSAJ AOY12USAJL COOLING 28.5 30.0 HEATING 28.0 COOLING 8.5 9.0 HEATING 7.0 COOLING 82 80 HEATING 78 PIPING CONDITION REFRIGERANT CIRCUIT MODELS DISCHARGE PRESSURE kg/cm2G SUCTION PRESSURE kg/cm2G DISCHARGE TEMP. C REFRIG. PIPE LENGTH m COOLING DISCHARGE AIR TEMP. C INDOOR ENTERING AIR…
-
TYPE
INDOOR UNIT OUTDOOR UNIT COOL COOL & HEAT AUY14FBAB AUY14UBAB AOY14FSDJ AOY14USDJL COOLING CAPACITY (kW) 4.10 3.95 HEATING CAPACITY (kW) 4.60 ELECTRICAL DATA POWER SOURCE (V) 230 FREQUENCY (Hz) 50 RUNNING CURRENT INPUT WATTS E.E.R. (A) (kW) (kW/kW) COOLING 6.3 6.3 HEATING 6.3 COOLING 1.39 1.40…
-
AUY14FBAB
AUY14UBAB AOY14FSDJ AOY14USDJL COOLING 31.0 31.0 HEATING 31.0 COOLING 9.0 9.0 HEATING 7.5 COOLING 75 77 HEATING 77 PIPING CONDITION REFRIGERANT CIRCUIT MODELS DISCHARGE PRESSURE kg/cm2G SUCTION PRESSURE kg/cm2G DISCHARGE TEMP. C REFRIG. PIPE LENGTH m COOLING DISCHARGE AIR TEMP. C INDOOR ENTERING AIR…
-
OUTLINE
AND DIMENSIONS INDOOR UNIT (unit : mm) ( 650) (Grille measurement) Drain pipe (I.D. 32) 250 600 (Ceiling opening measurement) 2004.05.12 (Hanging bolt position) 606 (Hanging bolt position) 400
-
OUTDOOR UNIT
(unit : mm) 2004.04.27 6
-
CIRCUIT
DIAGRAM Models : AUY12FBAB, AUY14FBAB Models : AOY12FSAJ, AOY14FSDJ 2004.07.01 7
-
Models : AUY12UBAB, AUY14UBAB
Models : AOY12USAJL, AOY14USDJL 2004.07.01 8
-
REFRIGERANT
SYSTEM DIAGRAM Models : AUY12FBAB / AOY12FSAJ INDOOR UNIT OUTDOOR UNIT Refrigerant pipe Distributor 6.35mm(1/4") Capillary tube Strainer Condenser Evaporator Refrigerant pipe 9.52mm(3/8") Charging valve Compressor Models : AUY12UBAB / AOY12USAJL OUTDOOR UNIT Refrigerant pipe Distributor Strainer…
-
Models : AUY14FBAB / AOY14FSDJ
INDOOR UNIT OUTDOOR UNIT Refrigerant pipe Distributor 6.35mm(1/4") Capillary tube Strainer Evaporator Condenser Refrigerant pipe 12.7mm(1/2") Charging valve Compressor Models : AUY14UBAB / AOY14USDJL OUTDOOR UNIT Distributor Strainer 6.35mm(1/4") Capillary tube Compressor Evaporator Condenser…
-
ERROR
Operation can be checked by lighting and flashing of the grille display section OPERATION and TIMER lamps. Perform judgment in accordance with the following. SWING CHECK ITEMS 1. INDOOR UNIT (1) Is operation of each button on the remote control unit normal? (2) Does each lamp light normally? (3) Do…
-
CONTROLLER PCB ASSEMBLY ( MAIN PCB )
-
DISASSEMBLY
-
2004.06.04 COOL & HEAT MODEL ONLY OUTDOOR UNIT
-
AOY12USAJL
AOY14FSDJ AOY14USDJL 2004.07.01 18
-
AOY14FSDJ
-
AOY12USAJL
AOY14FSDJ AOY14USDJL COOL & HEAT MODEL ONLY 815 37 218-3 983 824-4 823-2 982-1 982-2 32 982-1 2004.07.01 982-2 22
-
PARTS
W hen you order parts, please make a photocopy of this page and fill the number of the parts in the "Order" column. IN DOOR U N IT Ref. No. 2004.08.10 LIST Part No. Description AUY12FBAB AUY12UBAB AUY14FBAB AUY14UBAB 34 67 117-3 184-1 185 Capacitor (Fan Motor) R ubber S pecial Washer M6 Drain Hose S…
-
GRILLE ASSY (UTG-UDYD-W)
Ref. No. Description Filter Motor Cover Clamp S KB-150 Motor Gear Indicator PCB Assy Cover-A Insulation (Panel)-A Insulation (Panel)-B J oint-A J oint-B Part No. Ord. Ref. Q'ty No. 9359632009 9359623014 313035356905 9359629009 9702224011 9359622017 9359620006 9359621003 9359626008 9359627005 711-1…
-
When you order parts, please make a photocopy of this page
-
ACCESSORIES INDOOR UNIT ACCESSORIES Name and Shape Coupler heat insulation Application For indoor side pipe joint Part No. 9350716029 9352766015 Special nut A (large flange) For installing indoor unit Special nut B (small flange) For installing indoor unit Template For ceiling hole cutting…
Схемы, таблицы и рисунки — в просмотре документа выше. Клик по номеру страницы открывает её в просмотре.