SPLIT TYPE ROOM AIR
CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL type (50Hz) Models Indoor unit Outdoor unit RYT-24AB ROW-24AB C O N T E N T S SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 OUTLINE AND DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . .…
-
SPECIFICATIONS
-
OUTLINE
AND DIMENSIONS INDOOR UNIT 655 Unit : mm 990 199 [Rear View] OUTDOOR UNIT –2– 336
-
REFRIGERANT
SYSTEM DIAGRAM INDOOR UNIT OUTDOOR UNIT Refrigerant pipe ø 9.53 mm (3/8") Capillary tube Distributor Dryer Evaporator Condenser Refrigerant pipe ø 15.88 mm (5/8") Charging valve Cooling : Flare couping –4– Compressor
-
CIRCUIT
DIAGRAM Models : RYT-24AB / ROW-24AB FM CN201 FAN MOTOR GREEN/YELLOW DISPLAY BOARD CN8 THERMISTOR (ROOM TEMP.) THERMISTOR (PIPE TEMP.) BLACK GRAY BLACK WHITE WHITE BROWN YELLOW WHITE RED 2 1 ORANGE YELLOW WHITE CN4 BROWN CN10 RED CN11 MAIN RELAY GRAY 2 1 CN6 CN7 CONTROL BOARD 2 1 CN15 CN13 2 1 BROWN…
-
INDOOR
PRINTED CIRCUIT CIRCUIT DIAGRAM BOARD Model : RYT-24AB CONTROLLER PCB ASSEMBLY (MAIN PCB) ROOM TEMPERATURE THERMISTOR AUTO RESTART CHANGER CUSTOM CODE CHANGER CUSTOM CODE CHANGER HEAT EXCHANGER THERMISTOR SWITCHING TRANSFORMER EZ–0964HSE–P POWER SUPPLY PCB MANUAL AUTO SWITCH INDICATOR PCB…
-
P. C
BOARD L AY O U T S CONTROLLER P. C. BOARD ASSEMBLY (Viewed from the solder side) INDICATOR P. C. BOARD ASSEMBLY FILTER P. C. BOARD ASSEMBLY (Viewed from the solder side) (Viewed from the solder side) –5–
-
DISASSEMBLY
ILLUSTRATION Model : RYT-24AB 509 173 365-2 653-2 365-1 580 870-1 365-2 422 870-1 653-2 923 174 365-1 743 240 –7– 508
-
Model : ROW-24AB
CONTROL UNIT 38 187 824-4 37 34 218-3 823-2 815 36 32-1 – 15 –
-
RYT-24AB
PARTS When you order parts, please make a photocopy of this page and fill the number of the parts in the “Order” column. INDOOR UNIT Ref. Description LIST Part No. No. Ord. Q’ty Ref. Description Part No. No. 9356362008 9358621004 313659068604 9358563007 9359061014 9358543009 Grille Support Filter…
-
ROW-24AB
When you order parts, please make a photocopy of this page and fill the number of the parts in the “Order” column. OUTDOOR UNIT Ref. Description Part No. No. Ord. Q’ty Ref. Description Part No. No. Fan Cover 9350214020 Emblem-Rear “FUJI ELECTRIC” 9301702019 Cabinet-A, Painted 9303876015 Cabinet-C…
-
RYT-24AB
-
INDOOR UNIT ACCESSORIES
Name and Shape Use Part No. Cosmetic Panel-L 9358536018 Cosmetic Panel-R 9358535011 Tapping screw (ø4 x 10) 301171164104 Installation template Hanger bracket-L For positioning the indoor unit. For under ceiling type. 9359107002 For suspending the indoor unit from ceiling. 9358596005 Hanger bracket-R…
-
REMOTE CONTROL UNIT
Name and Shape Remote control unit Use Part No. Use for air conditioner operation 9359913061 Battery (penlight) For remote control unit 0600185534 Remote control unit holder For mounting the remote control unit 9359955016 Tapping screw (ø3 x 12) For remote control unit holder installation…
-