OUTLINE AND DIMENSIONS
UNIT : mm 655 INDOOR UNIT 199 990 [Rear View] OUTDOOR UNIT
-
REFRIGERANT SYSTEM DIAGRAM
Models : RYT-14 / ROY-14AA INDOOR UNIT Refrigerant pipe 12.7mm(1/2") Charging valve OUTDOOR UNIT 20 Discharge pipe 3-Way valve 18 Suction pipe Condenser Evaporator Compressor Strainer 272 19 Capillary tube 2-Way valve Refrigerant pipe 6.35mm(1/4") Models : RYT-14R ROY-14R ROY-14RA INDOOR UNIT…
-
CIRCUIT DIAGRAM
Models : RYT-14 / ROY-14AA THERMISTOR(ROOM TEMP.) THERMISTOR(PIPE TEMP.) FAN MOTOR CAPACITOR CN7 CN8 3 PURPLE GRAY 8 BLUE 1 FAN MOTOR GREEN / YELLOW FM 1 CONTROL BOARD 7 8 RED WHITE BLACK Use T3. 15A-250V Fuse on F101 CN12 L FILTER BOARD WHITE RED ORANGE YELLOW WHITE M BROWN RED ORANGE YELLOW WHITE…
-
ROY-14RA
THERMISTOR(ROOM TEMP.) THERMISTOR(PIPE TEMP.) FAN MOTOR CAPACITOR BLACK BLACK CN6 CN7 CN8 2 3 PURPLE GRAY 8 BLUE 1 FAN MOTOR GREEN / YELLOW FM CONTROL BOARD 7 8 RED WHITE BLACK Use T3. 15A-250V Fuse on F101 CN1 CN12 CN2 YELLOW WHITE 1 2 M BROWN RED ORANGE YELLOW WHITE 1 2 M MAIN RELAY L FILTER BOARD…
-
INDOOR PRINTED CIRCUIT BOARD
CIRCUIT DIAGRAM Model : RYT-14 CONTROLLER PCB ASSEMBLY (MAIN PCB) EZ-0985WSE-C ROOM TEMPERATURE THERMISTOR HEAT EXCHANGER THERMISTOR POWER SUPPLY PCB EZ-0964HSE-P MANUAL AUTO SWITCH INDICATOR PCB EZ-0964HSE-D FLOAT SWITCH 7
-
Model : RYT-14R
CONTROLLER PCB ASSEMBLY (MAIN PCB) ROOM TEMPERATURE THERMISTOR EZ-0985HSE-C HEAT EXCHANGER THERMISTOR POWER SUPPLY PCB EZ-0964HSE-P MANUAL AUTO SWITCH INDICATOR PCB EZ-0964HSE-D FLOAT SWITCH 8
-
CONTROLLER PCB ASSEMBLY (MAIN PCB) (Viewed from the component side) FILTER PCB ASSEMBLY (Viewed from the component side) 6
-
(Viewed from the solder side)
FILTER PCB ASSEMBLY INDICATOR PCB ASSEMBLY (Viewed from the solder side) (Viewed from the solder side) 7
-
Models : RYT-14 RYT-14R 9
-
Models : ROY-14AA
-
When you order parts, please make a photocopy of this page and fill the number of the parts in the "Order" column. INDOOR UNIT Ref. Ord. Part No. Description No. RYT-14 RYT-14R 3 8-1 34 36-2 Louver Air Filter Capacitor (Fan Motor) Cord Holder Metal Sirocco Fan Assy Rubber (Vibration-proof) Cap.…
-
When you order parts, please make a photocopy of this page
and fill the number of the parts in the "Order" column. INDOOR UNIT Ref. Ord. Part No. Description No. RYT-14 RYT-14R Cosmetic Panel-R Cosmetic Panel-L Control Box Cover Flap Base Louver Link Cover Insulation (Evaporator)-R Insulation (Evaporator)-L Flap Link-Upper (Step Motor-V) Flap Link-Lower…
-
ROY-14AA
ROY-14R ROY-14RA When you order parts, please make a photocopy of this page and fill the number of the parts in the "Order" column. OUTDOOR UNIT Ord. Part No. Ref. No. Description ROY-14AA ROY-14R ROY-14RA Fan Cover Emblem-Rear "FUJI ELECTRIC" Cabinet, Painted Connector Cover (Cabinet) Cabinet Rear…
-
[INDOOR UNIT]
-
INDOOR UNIT ACCESSORIES
Name and Shape Application Part No. Cosmetic Panel-L 9358536018 Cosmetic Panel-R 9358535011 Tapping screw ( 4 x 10) 301171164104 Installation template For positioning the indoor unit For under ceiling type. Hanger bracket-L For suspending the indoor unit from ceiling 9359107002 9358596005 Hanger…
-
REMOTE CONTROL UNIT
Name and Shape Application Remote control unit Use for air conditioner operation Battery (penlight) For remote control unit Remote control unit holder For mounting the remote control unit Tapping screws ( 3 x 12) For remote control unit holder installation RYT-14 RYT-14R 9359913061 (AR-DL6)…
-
0009J1744
September 2000 Printed in Japan