R FIND YOU MANUALS G OPERATs.IcoNm/ohmpilot-manuals iu www.fron Operating Instructions 42,0410,2141,EN EN Fronius Ohmpilot 001-14062017 Accessories
-
Introduction
EN Dear Reader, We would like to thank you for the trust you have placed in us and congratulate you on purchasing this high-quality Fronius product. These instructions will help you to familiarise yourself with the product. By reading the instructions carefully, you will learn about the diverse…
-
General Remarks
EN Safety Rules The device has been manufactured in accordance with the state of the art and the recognised safety rules. However, incorrect operation or misuse may result in: - Injury or death to the operator or third parties - Damage to the device and other property of the operator - Inefficient…
-
Choice of
Location The Ohmpilot is suitable for installation indoors. Do not install the Ohmpilot outdoors. The Ohmpilot corresponds to protection class IP 54 and is protected against spray water from all sides. In order to keep warming of the Ohmpilot to a minimum, do not expose it to direct sunlight.…
-
EN Explanation of Symbols Installation Position Do not install the Ohmpilot horizontally. Do not install the Ohmpilot on a sloping surface. Do not install the Ohmpilot on a sloping surface with its connection sockets facing upwards. Do not install the Ohmpilot at an angle on a vertical wall. Do not…
-
Do not install the Ohmpilot such that it overhangs with its connection
sockets facing upwards. Do not install the Ohmpilot such that it overhangs with its connection sockets facing downwards. Do not install the Ohmpilot on the ceiling. Choice of Location General Remarks The following criteria should be taken into account when choosing a location for the Ohmpilot…
-
The information on servicing contained in these operating instructions is
only intended for qualified personnel. An electric shock can be fatal. Do not carry out any activities other than those listed in the documentation. This also applies even if you are qualified to do so. All cables and leads must be secure, undamaged, insulated and adequately dimensioned. Arrange for…
-
General Remarks
Proper Use / Intended Purpose With its "24 hours of sun" vision, Fronius is aiming to offer its customers solutions for generating, storing, distributing and using energy in an intelligent and cost efficient manner. The use of surplus energy for hot water preparation constitutes a simple option…
-
Phase 1
Phase 2 Phase 3 0 - 3 kW 0 - 3 kW continuously variable - - 3 - 6 kW 0 - 3 kW continuously variable 3 kW fixed - 6 - 9 kW 0 - 3 kW continuously variable 3 kW fixed 3 kW fixed EN Power range Other resistive loads such as infrared heaters, towel dryers, etc. can also be controlled. WARNING! Only…
-
Warning Notices
on the Device Warning notices and safety symbols are located on the left-hand side of the Ohmpilot. These warning notices and safety symbols must not be removed or painted over. The notices and symbols warn of incorrect operation that could result in serious injury and damage to property. Safety…
-
Wall Mounting
Safety NOTE! The IP 54 protection class only applies if the cover is firmly screwed to the back. Selecting Wall Plugs and Screws IMPORTANT! Depending on the surface, different types of fixings are required for mounting the Ohmpilot. The fixings are therefore not included in the scope of supply for…
-
Fronius Smart Meter
Integrating the Fronius Smart Meter A Fronius Smart Meter is required for operation of the Ohmpilot, so that the surplus energy can be measured. For integration of the Fronius Smart Meter, an inverter with Datamanager 2.0 and software version V3.8.1-x or higher and/or a Datamanager Box (from…
-
Indications/Controls on the Device
1x WPS 2x ACCESS POINT 3x BOOST Press 1x WPS (Wi-Fi Protected Setup) is opened for 2 minutes or until successful pairing with the router. By pressing the WPS button the router, the WLAN password is transmitted to the Ohmpilot. Press 2x WLAN access point is activated for 30 minutes so that settings…
-
Selection of Heater
1-Phase Heater: - 0.3 to 3 kW Purely resistive load (no electronic temperature limiters, fans, etc.) 3-Phase Heater: - 0.9 to 9 kW Equal load distribution on all 3 phases (e.g. 3 x 3 kW) If a mechanical temperature switch is being used, it must switch all 3 phases simultaneously. Purely resistive…
-
G
2 B EN Wiring Diagram R 3 6 LAN 7 PT1000 5 RS485 4 D+ D- - R2 L1 L2 L3 N R3 L2 8 N 9 L3 N NC 10 8 W NO OUT N Green LED 2 Blue LED 3 Red LED 9 4 Button 10 OUTPUT - L3 heating element 5 Ethernet RJ45, at least CAT5, screened 11 6 Modbus RTU (default address 40) Spring balancer 0.2 - 1.5 mm2 max. 1000…
-
Stripping
Lengths Stripping length of terminals on power stage set (L1, L2, etc.) 10 mm Stripping length of terminals on control board (D+, D-, - and PT1000) 8 mm Electrical Connection IMPORTANT! Electrical connection work may only be carried out by a specialist. IMPORTANT! The ground conductor connection…
-
Spring balancer 1.5 - 2.5 mm2
NOTE! Phase and neutral conductors must not be mixed up. Residual current-operated circuit breaker is triggered. Functional Description 5 External source (e.g. gas-fired heating) 6 Heating element (max. 3 kW) 2 OUTPUT up to 3 kW variable, max. 13 A resistive load Spring balancer 1.5 - 2.5 mm2 7…
-
Spring balancer 1.5 - 2.5 mm2
NOTE! Phase and neutral conductors must not be mixed up. Residual current-operated circuit breaker is triggered. Functional Description 6 PT1000 temperature sensor 7 External source (e.g. gas-fired heating) 2 OUTPUT - L2 heating element 8 Heating element (max. 9 kW) 3 OUTPUT - L3 heating element 9…
-
Spring balancer 1.5 - 2.5 mm2
NOTE! Phase and neutral conductors must not be mixed up. Residual current-operated circuit breaker is triggered. 2 PT1000 temperature sensor 6 Heat pump with SG Ready control input NOTE! The voltage must be at least 15 V and the current at least 2 mA, so that the relay contacts do not oxidise.…
-
heat pump. If the heating element does not have a thermostat, the Ohmpilot can also
carry out this task as an alternative (see "Optional Settings" section). NOTE! This function can also be combined with a 3-phase heating element. 1. The section "Establishing the Data Connection" describes how you can access the Ohmpilot website. 2. Under HEATER 2, select "SG Ready heat pump" as the…
-
1-Phase Heating Element up to 3 kW and External
-
Spring balancer 1.5 - 2.5 mm2
NOTE! Phase and neutral conductors must not be mixed up. Residual current-operated circuit breaker is triggered. 2 PT1000 temperature sensor 6 External source (e.g. gas-fired heating) NOTE! The voltage must be at least 15 V and the current at least 2 mA, so that the relay contacts do not oxidise.…
-
1. The section "Establishing the Data Connection" describes how you can access the
Ohmpilot website. 2. Highlight the field "Temperature sensor present" 3. Highlight the field "Adapt day curve" 4. Under "Time from", enter the time from which the minimum temperature should be adjusted, and the specific minimum temperature. 5. Under "Target temperature", enter the required…
-
Two Heating Elements - 3-Phase and 1-Phase
-
Spring balancer 1.5 - 2.5 mm2
NOTE! Phase and neutral conductors must not be mixed up. Residual current-operated circuit breaker is triggered. Functional Description 8 External source (e.g. gas-fired heating) 9 Heating element 1 (max. 3 kW) 2 OUTPUT - L2 heating element 10 Buffer 3 OUTPUT - L3 heating element 11 4…
-
As an alternative, the Ohmpilot can also ensure the minimum temperature. This may result in electricity being sourced from the grid. The maximum temperature must be set on the heating element thermostat. If heating element 1 (9) does not have a thermostat, the Ohmpilot can also carry out this task…
-
Spring balancer 1.5 - 2.5 mm2
NOTE! Phase and neutral conductors must not be mixed up. Residual current-operated circuit breaker is triggered. Functional Description 8 PT1000 temperature sensor 9 External source (e.g. gas-fired heating) 2 OUTPUT - L2 heating element 10 Heating element 1 (max. 9 kW) 3 OUTPUT - L3 heating element…
-
installed, an external source (e.g. gas-fired heating) must ensure the minimum temperature
As an alternative, the Ohmpilot can also ensure the minimum temperature. This may result in electricity being sourced from the grid. The maximum temperature must be set on the heating element thermostat. If heating element 1 (10) does not have a thermostat, the Ohmpilot can also carry out this task…
-
Possible
Communication Channels EN Establishing the Data Connection The data connection is primarily required so that the inverter or Datamanager can share default values with the Ohmpilot. For some applications, however, it is also necessary to implement settings via the Ohmpilot website. There are 3…
-
Establishing a
Connection via Modbus RTU 1. Connect the bus cabling (B) to the Ohmpilot. (The bus cabling is carried out in parallel via the TX+, TX- and GND cables with the Fronius Smart Meter and the Fronius inverter or Datamanager 2.0). 2. Terminate the RS485 bus with a resistance at the first and last device.…
-
NOTE! In networks with a DNS suffix, the Ohmpilot can be reached at http://
ohmpilotW.<DNS- Suffix>. E.g. http://ohmpilotW.fronius.com 4. Implement the settings. Establishing a Connection via LAN As standard, the Ohmpilot obtains its IP address automatically from the DHCP server, meaning that no settings are generally necessary. The inverter automatically searches for the…
-
Establishing a
Connection via WLAN There are two options for connecting the Ohmpilot to an existing WLAN network: Connecting via WPS (WiFi Protected Setup) 1. Press the button on the Ohmpilot 1x. The blue LED flashes (once) for as long as the WPS is active. 2. Press the WPS button on the router within 2 minutes.…
-
IMPORTANT! When the access point is opened, it is not possible to scan the WLAN
networks. A static IP address can be assigned to the Ohmpilot via the web interface. The Ohmpilot can then be reached at http://ohmpilotW.local or at the fixed IP address assigned. Alternatively, the Fronius Solar.web app can also be used to search for the Ohmpilot in the network. NOTE! Only one…
-
Status Indication on Web Interface
Status OK Ohmpilot is operating in normal mode. TARGET TEMPERATURE Temperature has fallen below the minimum. Heater 1 is heating at 100%. LEGIONELLA PREVENTION Legionella heating is active. Heater 1 is heating at 100%. BOOST The Ohmpilot has been switched to boost mode manually. Heater 1 is heating…
-
Optional Settings
IMPORTANT! The settings described here can be implemented for all of the application examples detailed above. If they are not described for the relevant example, they are not vital. Manual Settings HEATER 1 You can also set the power of HEATER 1 manually. 1. To do this, select the "manual" field. 2.…
-
WARNING! No guaranteed legionella prevention
Adapting the Day Curve This function ensures that a required temperature is not undercut. If there is not sufficient surplus power available, the external source will be started up, if activated, or otherwise electricity will be drawn from the grid in order to ensure a minimum temperature. Up to…
-
Error List
Sending of Errors • Errors are saved in the Datamanager 2.0 and can be sent via Solar Web. • Possible error outputs (as of 07/12/2015): Code Description Cause Solution 906 Heating element 1 faulty short circuit L1 The load on L1 is higher than 3 kW. Short circuit on L1. Check heating element 1.…
-
Code
Description Cause Solution 925 Time not synchronised Time not synchronised in the last 24 hours. Router has been switched off/reconfigured. Check connection between Ohmpilot and inverter. Switch on router. Check network settings. 926 No connection to inverter No connection between inverter and…
-
Warranty Terms and Conditions, and Disposal
Fronius Manufacturer's Warranty Detailed, country-specific warranty terms are available on the internet: www.fronius.com/solar/warranty Disposal If you decide in the future to replace your Ohmpilot, Fronius will take back the old device and arrange for it to be recycled in an appropriate manner.…
-
Technical Data
Input Data Frequency Nominal voltage Max. input current Interfaces Modbus RTU LAN WLAN Temperature sensor RS 485, max. 1000 m, screened and twisted Ethernet at least CAT5, screened IEEE 802.11 b/g/n PT1000 (max. 30 m) Output Data Analogue out 1-phase/3-phase Analogue nominal voltage per phase…
-
Inspection / Specifications
Inspection / Specifications according to EN60730 Section 1 Table 7.2 6a Construction Electronic RS 2.5.5 independently mounted RS 19 Screwless Terminal 2.10.6.1 mounting method type Y 24 RS Classification, to Protect Against Electric Shock Section 6.8 Protection class I 6.8.3 29 Type of…
-
Fronius Worldwide - www.fronius.com/addresses
Fronius International GmbH 4600 Wels, Froniusplatz 1, Austria E-mail: pv-sales@fronius.com http://www.fronius.com Fronius USA LLC Solar Electronics Division 6797 Fronius Drive, Portage, IN 46368 E-mail: pv-us@fronius.com http://www.fronius-usa.com The addresses of all our sales branches and partner…