ARCEUS ELECTRIC
COMBI BOILER ARCEUS 6-9-12-15-18-24-27 kW MT / CH / ST USER AND INSTALLATION MANUAL
-
1- INTRODUCTION
First of all, thank you for choosing E.C.A. E.C.A. ARCEUS electric combi boilers are intended for meeting central heating and hot domestic water requirement in an efficient, safe, and comfortable manner. ARCEUS electric combi boilers can operate on 220-240 VAC (6/9/12 kW) and 380-415 VAC…
-
INFORMATION
These are descriptions containing information that should be taken intoconsideration by the user. CAUTION: Indicates that material damage or slight personal injury may occur. DANGER: Indicates that severe personal injury may occur. 4- SAFETY RULES AND WARNINGS 4.1- Safety Rules The power line to…
-
CAUTION: This device is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the device by a person responsible for their safety. Children should be supervised to ensure that they do not play with the…
-
5.2- Product Notation
NOTATION DESCRIPTION ARCEUS 12-15-18-24-27 MT ARCEUS Monothermic Electric Combi Boiler ARCEUS 6-9-12-15-18-24-27 CH ARCEUS Central Heating Electric Combi Boiler ARCEUS 6-9-12-15-18-24-27 ST ARCEUS Central Boiler Aided Electric Combi Boiler Table 1. Device Notation Table 7
-
5.3- Wiring Diagrams
21 13 5/L3 3/L2 1/L1 -Q A1 Circuit Breaker 22 14 6/T3 4/T2 2/T1 Neutral Bus Bar A2 Contactor Overheat Thermostat Electric Heaters Relay Board CH Flow NTC CH Return NTC Boiler Tank NTC 3 Way Valve DHW Solar STB Water Pressure Sensor DHW Outlet Sensor Modbus Communication Circulation Pump Cascade…
-
13 5/L3 3/L2 1/L1 -Q A1 Circuit Breaker 22 14 6/T3 4/T2 2/T1 Neutral Bus Bar A2 Contactor Overheat Thermostat Electric Heaters Relay Boards CH Flow NTC CH Return NTC Boiler Tank NTC 3 Way Valve DHW Solar STB Water Pressure Sensor DHW Outlet Sensor Modbus Communication Circulation Pump Cascade Board…
-
5/L3 13 3/L2 1/L1 -Q A1 Circuit Breaker 22 14 6/T3 4/T2 2/T1 Neutral Bus Bar A2 Contactor Overheat Thermostat Electric Heaters Relay Boards CH Flow NTC CH Return NTC Boiler Tank NTC 3 Way Valve DHW Solar STB Water Pressure Sensor DHW Outlet Sensor Modbus Communication Circulation Pump Cascade Board…
-
13 5/L3 3/L2 1/L1 A1 21 13 5/L3 3/L2 1/L1 -Q A1 Circuit Breaker -Q Contactor Electric Heaters 22 14 6/T3 4/T2 A2 2/T1 22 14 6/T3 4/T2 2/T1 Neutral Bus Bar A2 Contactor Overheat Thermostat Electric Heaters Relay Boards CH Flow NTC CH Return NTC Boiler Tank NTC 3 Way Valve DHW Solar STB Water Pressure…
-
5.4- Detailed View, Component List and Installation
Figure 5. Component View of Device 1. 2. 3. 4. 5. 6. 7. Air Purge Circuit Breaker Ground Terminal Block Neutral Terminal Block Neutral Busbar Cantactor 3 Way Valve 12 8. 9. 10. 11. 12. 13. 14. 15. 3 Bar Safety Valve Electric Heaters Main Heat Exchanger Expansion Vessel Drain Valve Plate Heat…
-
Control Board
Figure 6. Control Panel Elements Figure 6.1 Control Board Rear Cover and Terminal Connections 13
-
5.4.1- MT Model Installation
DHW Outlet DHW Inlet CH Return CH Flow Figurel 7. Monothermic Device Installation Scheme 5.4.2- CH Model Installation CH Flow CH Return Figure 8. CH Device Installation Scheme 14
-
5.4.3- ST Model Installation
Boiler Exit CH Return CH Exit Boiler Return Figure 9. ST Device Installation Scheme 6- PACKAGE CAUTION: Warnings on the carton package must be observed during transportation and storage of the device. - The device is delivered in a carton box with dimensions of 735 x 345 x 490 (HxWxD) as supported…
-
Upper side service space
Min. 500 mm. Left and right side servicee space Min. 150 mm. Bottom side service space Min. 250 mm. Figure 10- Required spaces for the assembly of the device - The device can not be used at altitudes higher than 2000 m above sea level. - There is no need to remove side panels for the inside combi…
-
Figure 11. Bracket Assembly
8- CONNECTIONS 8.1- Water Pipe Connections - The water connections between the wall mounting bracket fixed on the wall and the combi boiler are made with the pipe group and nipples as shown in the figure. 8.1.1- MT Model a) Central heating pipe 3/4" outlet line (hot) b) Domestic water pipe 1/2"…
-
8.1.2- HCH Model
a)Central heating pipe 3/4" outlet line (hot) b)Central heating pipe 3/4" return line (cold) b a Figure 13. CH boiler water connections 8.1.3- HST Model a)Central heating pipe 3/4" outlet line (hot) b) Boiler outlet line 1/2" (hot) c) Boiler return line 1/2" (cold) d) Installation Filling line 1/2"…
-
8.2- Electrical Connection
Your combi boiler must be connected to a grounded power line that can supply 230 VAC 50 Hz voltage for single-phase devices and 400 VAC 50 Hz voltage for 3-phase devices. Malfunctions caused by voltage fluctuations are not covered by the warranty. DANGER: When making the electrical connection of the…
-
CAUTION: For single-phase operation, a power supply
cord with suitable cross section defined for singlephase operation must be used. Figure 16. Bridging bar CAUTION: Bridging bar must not be used in 3-phase operation. CAUTION: Malfunctions caused by power supply grid are not associated with the device and are not covered by warranty. Device Power…
-
8.3 Room Thermostat
-
9- INITIAL START-UP, OPERATION AND SHUT DOWN
9.1- Initial Start-Up - First of all, the electrical connection of combi boiler should be made. The electrical connection of the device must be connected to a grounded supply line that can supply sufficient voltage for the device. - All radiator valves are opened. - The radiator outlet-return valves…
-
10- CONTROL PANEL
10.1- Button Functions Reset/Mode Selection Button Using mode can be changed by pressing the mode selection button to change between the winter mode and the summer mode. If the button is pressed for 3 seconds, the device will switch to the "stand by" position. It will be enough to press the button…
-
K5
K6 K1 K3 K4 Figure 18. Control Panel Button Configuration 10.2.1 Button Functions: Button Number K4 K3 K6 Button Name Function CH Plus - Increases central heating set temperature - Increases password value at parameter menu entry - Increases parameter value - Indicates information value - Indicates…
-
K5
DHW Minus K1 Mode K3 & K4 CH+ & CH- - Reduces domestic water set temperature - Allows for selection between parameters, information, error history, and clear error history menus - Confirms the password at parameter menu entry - Reduces parameter number - Shows information number - Reduces fault…
-
10.3.5- Domestic Hot Water (DHW) Eco Mode: At the times that hot water demand is not
expected (e.g. holidays etc.) or more economic use is preferred, ECO mode prevents the water in the exchanger to be heated and provides a more economic use of the device. When the ECO Mode is active “EC” letters are shown on the pressure indicator field. ECO mode can be activated by pressing K5 and…
-
10.4- Error Preventive Functions
10.4.1- Anti Freeze Protection: During the winter season, when the water temperature of the installation drops below 6⁰C, anti freze protection is activated and the device keeps on heating until water temperature reaches to 15⁰C. Below conditions must be provided and controlled by the customer for…
-
Low Water Pressure
Outdoor Temperature Sensor Error High Water Pressure Water Filling In Progress Error Water Filling Timeout Error Low Pressure Error After Water Filling Attempt Water Pressure Sensor Error Solar Boiler Tank Temperature Sensor Error Solar Panel Temperature Sensor (PT1000) Error Domestic Water Sensor…
-
• If you use a program clock with your device, your combi boiler will run at the times you set and
consume less fuel. • If you use your combi boiler with a room thermostat, it keeps the room temperature at the level you set, reducing fuel consumption. • Covering the radiator top and sides with furniture-like things adversely affects hot air circulation, thus prevents the environment from heating…
-
14.TECHNICAL DATA TABLE
-
15- ERP MANUAL
1- PRODUCT FICHES Product fiche for combination boilers as required by EU regulations No 811/2013 Units ARCEUS Combi ERP MT Model Supplier's name or trademark E.C.A. Arceus 12 Arceus 15 Arceus 18 Arceus 24 Arceus 27 kW kW kW kW kW Medium Supplier's model identifier Space Heating-Temperature…
-
SELLER COMPANY'S
Invoice Date and No: Title : Address : Submit Date and Location: Tel - Fax : Date, Signature and Seal: PRODUCT'S Type : Electric Boiler Serial Number Brand : E.C.A. Model : : Submit Date and Location: Maximum Repair Time: 20 Work Days Warranty Time : 3 Years AUTHORIZED SERVICE Title : Address…
-
PRODUCTION
7006910085 - 2.0 Organize Sanayi Bolgesi 3.Kisim Mustafa Kemal Boulevard No:13 45030 MANISA Tel.:+90 Fax:+90 email:emas@emas.com.tr www.emas.com.tr