Каталог Schneider Electric 2019 - Преобразователи частоты Altivar 1200C
Каталог Schneider Electric 2019 - Преобразователи частоты среднего напряжения Altivar 1200C 275...19052kVA
Загружаем документ…
Текст каталога
-
275...19052kVA
Selection Guide English MVD05101-01EN 05/2019 05/2019 www.schneider-electric.com
-
Important Information
This document covers the general introduction to the performance and/or technical characteristics of the said product. It is not intended to justify the applicability or reliability of the product in particular application of the user or replace the former guides. The user or integrator shall be…
-
Overview
Altivar 1200C Medium-voltage VFD System Drive Type Pump, fan, compressor, belt conveyor, etc. Model ATV 1200C Introduction Phase-shifting transformer, low-voltage power cells in series connection, output clean sinusoidal wave, low du/dt value (input and output) Power Range 275...19052kVA Voltage…
-
Medium-voltage VFD System
Application Cement ■■ Kiln head fan ■■ Preheating fan ■■ Kiln filter fan ■■ Rotary kiln (single drive, multidrive) ■■ Cement mill (multi-drive) Water & Waste Water ■■ Water intake pump ■■ Water supply pump ■■ Primary suction pump ■■ Secondary clean water pump Coal mine ■■ Belt conveyor (single…
-
Medium-voltage VFD System
Introduction ATV1200C Medium-voltage VFD is highly reliable, easy to operate and exceptionally efficient. ATV1200C is applicable to 3-phase mMedium-voltage asynchronous motor and synchronous motor (vector control with/without speed sensor, and V/f control mode). It is equipped with the…
-
Medium-voltage VFD System
Standards and rules ATV1200C is designed in strict accordance with international standards in all power range. Low-voltage standard To meet IEC standards, low-voltage mechanical and electrical design of ATV1200C comply with European standards LVD 2006/95/EC and IEC 61800-51 as well as equivalent GB…
-
Medium-voltage VFD System
Control cabinet and transformer cabinet The control part is modularly arranged in front of the transformer. The control part has a separate channel, and other components can be integrated as required by the user. Advantages ■■ Optimal space design can avoid the components being squeezed and…
-
Medium-voltage VFD System
Cooling solution Cooling arrangement of the transformer is innovatively optimized without additional air cooling device at the bottom. Fewer fans save maintenance costs and make the VFD has higher usability. The resuction of fans improves the overall efficiency of ATV1200C series VFD. The air…
-
Medium-voltage VFD System
Control characteristics With the friendly and easy-to-use LCD touch screen, the user can quickly find the desired results after a few touches. ■■ Motor control mode ■■ V/f control, and vector control with/without sensor Operation quadrants Two ■■ Static performance Open loop static accuracy of…
-
Medium-voltage VFD System
Optional H series bypass cabinet ■■ Voltage: 7.2 kV/12 kV ■■ Type: manual and automatic ■■ Current: up to 250 A ■■ Size (without base): 2,320 mm (H) x 1,300 mm (W) x 1,400 mm (D) ■■ Protection level: IP31 H series bypass cabinet Web APP Mobile APP Digital Operation Center VFD adviser intelligent…
-
Order List
Altivar 1200C Medium-voltage VFD System The product design of ATV1200C includes several reference points (letters and numbers). The meaning of each reference point can be illustrated with the following example (standard products only). ATV1200C -A Series name 470 - Cooling type: VFD (kVA) “A”…
-
Selection and
-
таблицы и схемы — в просмотре
-
Basic Technical Data
Altivar 1200C Medium-voltage VFD System General Technical Data Input 30 and 48-pulse diode rectifier Output Multi-level PWM waveforms output by two-level low-voltage IGBT inverter unit in series Input Voltage ■■ 6kV; 6.6kV; 10kV; 11kV ■■ Variation amplitude: standard value ±10% Allowable Voltage…
-
6kV,10kV
-
Medium-voltage VFD System
Altivar1200C Medium-voltage VFD system is born to serve you! Our VFDs are customized and fully equipped. We can find the right one for you. MVD05101-01EN 05/2019 15
-
Medium-voltage VFD System
Output voltage 6 kV Technical Data (output voltage 6 kV) ATV1200C A275-6060A3●● A315-6060A3●● A350-6060A3●● 9400 9400 9400 2710 2740 2760 2047×1700×2671 2047×1700×2671 2047×1700×2671 Standard symmetrical cable Refer to drawings Standard symmetrical cable Refer to drawings Standard symmetrical cable…
-
таблицы и схемы — в просмотре
-
Medium-voltage VFD System
Output voltage 6 kV Technical Data (output voltage 6 kV) ATV1200C A400-6060A3●● A445-6060A3●● A500-6060A3●● 9400 9400 9400 2849 2850 3000 2047×1700×2671 2047×1700×2671 2047×1700×2671 Standard symmetrical cable Refer to drawings Standard symmetrical cable Refer to drawings Standard symmetrical cable…
-
таблицы и схемы — в просмотре
-
Medium-voltage VFD System
Output voltage 6 kV Technical Data (output voltage 6 kV) ATV1200C A565-6060A3●● A625-6060A3●● 10800 10800 3100 3453 2047×1700×2671 2047×1700×2671 Standard symmetrical cable Refer to drawings Standard symmetrical cable Refer to drawings 3-core Refer to drawings 3-core Refer to drawings 2000m 2000m…
-
таблицы и схемы — в просмотре
-
Medium-voltage VFD System
Output voltage 6 kV Technical Data (output voltage 6 kV) ATV1200C A700-6060A3●● A790-6060A3●● A890-6060A3●● 10800 10800 13400 3685 3865 4182 2047×1700×2821 2047×1700×2821 2047×1700×2821 Standard symmetrical cable Refer to drawings Standard symmetrical cable Refer to drawings Standard symmetrical…
-
таблицы и схемы — в просмотре
-
Medium-voltage VFD System
Output voltage 6 kV Technical Data (output voltage 6 kV) ATV1200C A1000-6060A3●● A1125-6060A3●● 1000 1125 13400 14800 4584 5056 3460×1600×2671 3460×1600×2671 Standard symmetrical cable Refer to drawings Standard symmetrical cable Refer to drawings 3-core Refer to drawings 3-core Refer to drawings…
-
Medium-voltage VFD System
Output voltage 6 kV ATV1200C-A1000-6060A3●● Front view Bottom size Cable connection ATV1200C-A1125-6060A3●● Front view Bottom size MVD05101-01EN 05/2019 Cable connection 25
-
Medium-voltage VFD System
Output voltage 6 kV Technical Data (output voltage 6 kV) ATV1200C A1250-6060A3●● A1400-6060A3●● 1250 1400 1000 1120 14800 14800 5539 5490 3460×1600×2821 3962×1600×2821 Standard symmetrical cable Refer to drawings Standard symmetrical cable Refer to drawings 3-core Refer to drawings 3-core Refer to…
-
таблицы и схемы — в просмотре
-
Medium-voltage VFD System
Output voltage 6 kV Technical Data (output voltage 6 kV) ATV1200C A1565-6060A3●● A1750-6060A3●● A1875-6060A3●● 1565 1750 1875 1250 1400 1500 16800 16800 16800 5720 6288 6640 3962×1700×2821 3962×1600×2821 3962×1600×2821 Standard symmetrical cable Refer to drawings Standard symmetrical cable Refer to…
-
таблицы и схемы — в просмотре
-
Medium-voltage VFD System
Output voltage 6 kV Technical Data (output voltage 6 kV) ATV1200C A2000-6060A3●● A2250-6060A3●● A2500-6060A3●● 2000 2250 2500 1600 1800 2000 16800 16800 16800 7012 7549 7899 3962×1600×2821 4262×1700×2821 4964×1700×2821 Standard symmetrical cable Refer to drawings Standard symmetrical cable Refer to…
-
таблицы и схемы — в просмотре
-
Medium-voltage VFD System
Output voltage 6 kV Technical Data (output voltage 6 kV) ATV1200C A2800-6060A3●● A3125-6060A3●● A3500-6060A3●● 2800 3125 3500 2240 2500 2800 26200 26200 26200 8459 8720 9208 4964×1700×2821 4964×1700×2821 4964×1700×2821 Standard symmetrical cable Refer to drawings Standard symmetrical cable Refer to…
-
Medium-voltage VFD System
Output voltage 6 kV ATV1200C-A2800-6060A3●● Front view Bottom size Cable connection ATV1200C-A3125-6060A3●●…ATV1200C-A3500-6060A3●● Front view Bottom size MVD05101-01EN 05/2019 Cable connection 33
-
Medium-voltage VFD System
Output voltage 6 kV Technical Data (output voltage 6 kV) ATV1200C A3940-6060A3●● Rated Data Model Rating [kVA] 3940 Motor Power [kW] 3150 Rated Current [A] Standard Overload 120% Maximum Output Current [A] Allow 1 Minute Every 10 Minutes 380 456 Power Cell Number of Cell per Phase 5 Characteristics…
-
Medium-voltage VFD System
Output voltage 6 kV ATV1200C-A3940-6060A3●● Front view Bottom size MVD05101-01EN 05/2019 Cable connection 35
-
Medium-voltage VFD System
Output voltage 10 kV Technical Data (output voltage 10 kV) ATV1200C A275-1010A3●● A315-1010A3●● A350-1010A3●● 10000 10000 10000 3260 3280 3300 2652×1700×2671 2652×1700×2671 2652×1700×2671 Standard symmetrical cable Refer to drawings Standard symmetrical cable Refer to drawings Standard symmetrical…
-
таблицы и схемы — в просмотре
-
Medium-voltage VFD System
Output voltage 10 kV Technical Data (output voltage 10 kV) ATV1200C A400-1010A3●● A445-1010A3●● A500-1010A3●● 10000 10000 10000 3460 3460 4560 2652×1700×2671 2652×1700×2671 2652×1700×2671 Standard symmetrical cable Refer to drawings Standard symmetrical cable Refer to drawings Standard symmetrical…
-
таблицы и схемы — в просмотре
-
Medium-voltage VFD System
Output voltage 10 kV Technical Data (output voltage 10 kV) ATV1200C A565-1010A3●● A625-1010A3●● A700-1010A3●● 11400 11400 11400 3700 3830 3920 2652×1700×2671 2652×1700×2671 2652×1700×2671 Standard symmetrical cable Refer to drawings Standard symmetrical cable Refer to drawings Standard symmetrical…
-
таблицы и схемы — в просмотре
-
Medium-voltage VFD System
Output voltage 10 kV Technical Data (output voltage 10 kV) ATV1200C A790-1010A3●● A890-1010A3●● A1000-1010A3●● 790 890 1000 11400 14000 11400 4070 4220 4224 2652×1700×2671 2652×1700×2671 2652×1700×2671 Standard symmetrical cable Refer to drawings Standard symmetrical cable Refer to drawings Standard…
-
таблицы и схемы — в просмотре
-
Medium-voltage VFD System
Output voltage 10 kV Technical Data (output voltage 10 kV) ATV1200C A1125-1010A3●● A1250-1010A3●● A1400-1010A3●● 1125 1250 1400 900 1000 1120 16800 16800 16800 4228 4232 4236 2652×1700×2671 2652×1700×2741 2652×1700×2741 Standard symmetrical cable Refer to drawings Standard symmetrical cable Refer to…
-
Medium-voltage VFD System
Output voltage 10 kV ATV1200C-A1125-1010A3●● Front view Bottom size Cable connection ATV1200C-A1250-1010A3●●… ATV1200C-A1400-1010A3●● Front view Bottom size MVD05101-01EN 05/2019 Cable connection 45
-
Medium-voltage VFD System
Output voltage 10 kV Technical Data (output voltage 10 kV) ATV1200C A1565-1010A3●● A1750-1010A3●● 1565 1750 1250 1400 16800 16800 5775 5950 4264×1600×2821 4264×1700×2821 Standard symmetrical cable Refer to drawings Standard symmetrical cable Refer to drawings 3-core Refer to drawings 3-core Refer to…
-
Medium-voltage VFD System
Output voltage 10 kV ATV1200C-A1565-1010A3●● Front view Bottom size Cable connection ATV1200C-A1750-1010A3●● Front view Bottom size MVD05101-01EN 05/2019 Cable connection 47
-
Medium-voltage VFD System
Output voltage 10 kV Technical Data (output voltage 10 kV) ATV1200C A2000-1010A3●● A2250-1010A3●● 2000 2250 1600 1800 16800 24200 6833 7819 4264×1700×2821 5164×1700×2821 Standard symmetrical cable Refer to drawings Standard symmetrical cable Refer to drawings 3-core Refer to drawings 3-core Refer to…
-
таблицы и схемы — в просмотре
-
Medium-voltage VFD System
Output voltage 10 kV Technical Data (output voltage 10 kV) ATV1200C A2500-1010A3●● A2800-1010A3●● A3125-1010A3●● 2500 2800 3125 2000 2240 2500 24200 24200 24200 8168 8619 9312 6364×1500×3041 6364×1500×3041 6364×1500×3041 Standard symmetrical cable Refer to drawings Standard symmetrical cable Refer…
-
таблицы и схемы — в просмотре
-
Medium-voltage VFD System
Output voltage 10 kV Technical Data (output voltage 10 kV) ATV1200C A3500-1010A3●● A3940-1010A3●● 3500 3940 2800 3150 24200 24200 10062 11253 6364×1500×3041 6364×1600×3041 Standard symmetrical cable Refer to drawings Standard symmetrical cable Refer to drawings 3-core Refer to drawings 3-core Refer…
-
Medium-voltage VFD System
Output voltage 10 kV ATV1200C-A3500-1010A3●● Front view Bottom size Cable connection ATV1200C-A3940-1010A3●● Front view Bottom size MVD05101-01EN 05/2019 Cable connection 53
-
Medium-voltage VFD System
Output voltage 10 kV Technical Data (output voltage 10 kV) ATV1200C A4190-1010A3●● A4440-1010A3●● A4750-1010A3●● 4190 4440 4750 3350 4550 3800 37800 37800 37800 11747 12395 12915 7468×1600×3041 7468×1600×3041 7468×1600×3041 Standard symmetrical cable Refer to drawings Standard symmetrical cable…
-
Medium-voltage VFD System
Output voltage 10 kV ATV1200C-A4190-1010A3●●…ATV1200C-A4440-1010A3●● Front view Bottom size Cable connection ATV1200C-A4750-1010A3●● Front view Bottom size MVD05101-01EN 05/2019 Cable connection 55
-
Medium-voltage VFD System
Output voltage 10 kV Technical Data (output voltage 10 kV) ATV1200C A5000-1010A3●● A5625-1010A3●● A6250-1010A3●● 5000 5625 6250 4000 4500 5000 32200 32200 37600 14817 16010 17837 7468×1600×3041 7468×1600×3041 9374×1700×3041 Standard symmetrical cable Refer to drawings Standard symmetrical cable…
-
Medium-voltage VFD System
Output voltage 10 kV ATV1200C-A5000-1010A3●●…ATV1200C-A5625-1010A3●● Front view Bottom size Cable connection ATV1200C-A6250-1010A3●● Front view Bottom size MVD05101-01EN 05/2019 Cable connection 57
-
Quote Form
Medium-voltage VFD System Instruction: Inquirer shall fill in the blank parameter value manually. The mark “●” indicates “mandatory”. Please fill in the rest as much as possible. If not filled, standard practice shall prevail. Optional configuration will result in a considerable increase in cost. If…
-
Quote Form
Medium-voltage VFD System Analog Input/Output Analog input standard 4-way; expansion: __________(please specify special requirements) Analog output standard 2-way; expansion: __________(please specify special requirements) Indoor Temperature Minimum__________℃ Maximum__________℃ Outdoor Temperature…
-
2015 Schneider Electric All Rights Reserved
Make the most of your energyTM. MVD05101-01EN 05/2019
Схемы, таблицы и рисунки — в просмотре документа выше. Клик по номеру страницы открывает её в просмотре.