Текст каталога
-
Japanese Technology since 1912
MULTIGO Data Book 60Hz
-
CONTENTS
60Hz Rev. E Page ① - SPECIFICATIONS 200 - CONSTRUCTIONS 300 PERFORMANCE RANGE and SELECTION CHART TYPE KEY and CURVES SPECIFICATIONS PERFORMANCE CURVES MULTIGO 40 PERFORMANCE CURVES MULTIGO 80 SECTIONAL VIEW DRAWING SECTIONAL VIEW TABLE QUANTITY FOR MODEL BEARINGS MECHANICAL SEAL - DIMENSIONS and…
-
SPECIFICATIONS
60Hz Rev. E Liquid Type of liquid Handled Max temperature Maximum working pressure Maximum available negative suction head Impeller Construction Shaft seal type Bearing Suction Pipe Connection Discharge Casing Casing cover Impeller Diffuser Material Shaft PUMP [°C] [MPa] Clean water 40 1 [m] -6…
-
PERFORMANCE RANGE and SELECTION CHART
60Hz Rev. E PERFORMANCE RANGE SELECTION CHART Pump type Output Q=Capacity l/min m³/h 0 1,2 1,8 2,4 3,6 4,8 6 7,2 Single-phase Three-phase kW HP MULTIGO M40/86 MULTIGO 40/86 0,6 0,8 53 47,5 43,5 39,5 28,5 15,5 - - MULTIGO M40/106 MULTIGO 40/106 0,75 54,5 48,5 35 19,2 - - MULTIGO M40/126 MULTIGO…
-
TYPE KEY and CURVES SPECIFICATIONS
60Hz Rev. E TYPE KEY MULTIGO M 40 / 10 6 IN-LINE ONLY FOR IN-LINE VERSION 60 Hz MODEL POWER CODE HYDRAULIC CODE HP 0.8 HP 1 HP 1.2 HP 1.5 HP ONLY SINGLE PHASE MODEL CURVES SPECIFICATIONS The specifications below qualify the curves shown on the following pages. Tolerances according to ISO 9006:2012…
-
PERFORMANCE CURVES
60Hz Rev. E MULTIGO 40/86 – Impeller diameter = 90 mm MULTIGO 40/106 – Impeller diameter = 90 mm MULTIGO 40/126 – Impeller diameter = 90 mm MULTIGO 40/156 – Impeller diameter = 90 mm Rotation speed: ≈3450min-1 Test standard: ISO 9006:2012 - Grade 3B 203 EBARA Pump Europe S.p.A.
-
PERFORMANCE CURVES
60Hz Rev. E MULTIGO 80/126 – Impeller diameter = 85 mm MULTIGO 80/156 – Impeller diameter = 85 mm MULTIGO 80/206 – Impeller diameter = 85 mm Rotation speed ≈ 3450 min-1 Test standard: ISO 9006:2012 - Grade 3B 204 EBARA Pump Europe S.p.A.
-
CONSTRUCTIONS
60Hz Rev. E SECTIONAL VIEW DRAWING STANDARD VERSION IN-LINE VERSION 300 EBARA Pump Europe S.p.A.
-
CONSTRUCTIONS
60Hz Rev. E SECTIONAL VIEW TABLE PART NAME N° 1 Casing 4 Casing ring 6 Shaft with rotor 7 Impeller 9 Diffuser 10 Motor side mechanical seal 11 Pump side mechanical seal 12 Motor frame with stator 13 Motor cover 16 Terminal 19 Lower side ball bearing 20 Upper side ball bearing 21 Adjiusting ring 22…
-
CONSTRUCTIONS
60Hz Rev. E QUANTITY FOR MODEL POS. 7 POS. 9 POS. 62 Impeller Diffuser Stage housing Pump type MULTIGO 40/86 MULTIGO 40/106 MULTIGO 40/126 MULTIGO 40/156 MULTIGO 80/126 MULTIGO 80/156 BEARINGS Pump type Ball Bearings Single Phase Three Phase Pump side Fan side MULTIGO 40/86 M MULTIGO 40/86 6303 ZZ…
-
CONSTRUCTIONS
60Hz Rev. E MECHANICAL SEAL REF PART NAME MATERIAL Standard version A B C D E F G H I L M N Rubber seat Stationary ring Rotary ring Rotary seal Coil spring Seal cover Rubber seat Stationary ring Rotary ring Rotary seal Coil spring Seal cover NBR Ceramic Carbon NBR AISI 304 AISI 304 NBR Ceramic…
-
DIMENSIONS and WEIGHT
60Hz Rev. E PUMP STANDARD VERSION IN-LINE VERSIONE Pump Type H (mm) Standard version H (mm) IN-LINE version MULTIGO 40/86 MULTIGO 40/106 MULTIGO 40/126 MULTIGO 40/156 MULTIGO 80/126 573 MULTIGO 80/156 MULTIGO 80/206 598 624 Weight [kgf] [1~] [3~] 15,7 15,4 16,7 16,5 18,6 19,7 18,3 19,1 527 17,6 17,3…
-
DIMENSIONS and WEIGHT
60Hz Rev. E PACKING Pump type Packing [mm] Single Phase Three Phase X Y Z Weight [kgf] [1~] [3~] MULTIGO M 40/86 MULTIGO 40/86 16,5 16,2 MULTIGO M 40/106 MULTIGO 40/106 17,5 17,3 MULTIGO M 40/126 MULTIGO 40/126 19,5 19,1 MULTIGO M 40/156 MULTIGO 40/156 20,5 20 MULTIGO M 80/126 MULTIGO 80/126 18,4…
-
TECHNICAL DATA
60Hz Rev. E MOTOR DATA Pump type Single Phase Three Phase Pow er Capacitor kW HP Single Phase [µF] [V] Input Full load current Locked rotor current [kW] [A] [A] Single Three Single Phase Three Phase Single Phase Three Phase Phase Phase 220-230 V 380 V 220-230 V 380 V MULTIGO 40/86 M MULTIGO 40/86…