Каталог продукции AVK 2020 - Арматура для противопожарной защиты
Загружаем документ…
Текст каталога
-
AVK FIRE PROTECTION
FIRE DOESN’T COMPROMISE NEITHER SHOULD YOU
-
LET’S MAKE
A DIFFERENCE WHEN EVERY SECOND COUNTS Firemen depend fully on valves and hydrants that function perfectly, since they are installed in systems aimed to protect and save lives and safeguard valuables. Reliability is crucial when every second counts and system downtime for maintenance and replacement…
-
DRY BARREL
FIRE HYDRANTS Dry barrel fire hydrants are primarily designed for areas with frost, where the water main is located below the ground frost zone. AVK dry barrel fire hydrants meet or exceed AWWA C-502 and are UL/ULC listed and FM approved. They are designed for high performance, easy repair and…
-
Numerous design features
• High pressure rating - 17.2 bar (250 PSI) • 2 x 2½" NST hose nozzles + 1 x 4" NST pumper nozzle. Nozzles available in most thread configurations • 360° nozzle section rotation possible • Removable nozzles secured with external stainless steel allen screw • Travel stop nut in the nozzle section for…
-
DRY BARREL MONITOR
FIRE HYDRANTS Monitor hydrants are primarily used for installation in chemical and petrochemical industrial plants as well as refineries, tank farms, airports and other plants with large quantities of inflammable liquids posing fire hazards. Fast and effective fire extinguishing The AVK monitor…
-
AVK’s standard monitor
Our high quality FM approved monitor is cast completely in brass for high corrosion resistance. The special casting shape with a cast-in guideway in the middle ensures a high flow rate of up to 4732 liters/min. fast control, but it is also available with dual handwheels. It has a high vertical…
-
WET BARREL
FIRE HYDRANTS Wet barrel fire hydrants are primarily designed for nonfrost areas. AVK’s wet barrel hydrant is designed to be easy to maintain, enabling one person to perform routine repairs and maintenance. The hydrant is rated for a working pressure of 13,7 bar (200 PSI), is UL listed and FM…
-
©Vejle Brandvæsen
Fire protection | 9
-
POST INDICATORS
AND GATE VALVES FOR POST INDICATORS Post indicators are mounted end-to-end with the extension spindle connecting the valve, for intance on gate valves mounted on a water ring main in an airport or a factory area with e.g. oil refineries or chemical plants. Open or closed position The post indicator…
-
Resilient seated gate valves
A published test performed in City of Roseville, US, has proved that impurities up to Ø 8.7 mm can be handled by a DN150 mm valve without any problems. The same test proved that the unique AVK EPDM rubber quality is the only rubber quality which instantly returns to the original shape when the valve…
-
GATE VALVES
FOR SPRINKLER SYSTEMS AVK resilient seated gate valves are designed with a fully vulcanised rubber wedge and a lot of unique features ensuring optimum performance and high durability. We offer flanged gate valves in OS&Y design and with position indicator as well as grooved end valves with position…
-
VdS approved gate valves
The flanged gate valve with position indicator is suitable for use in fire protection systems as an isolating gate valve for maintenance purpose. The position indicator indicates the wedge position. Micro switches for remote indication of the wedge position are available as an optional extra. Yoke…
-
CHECK VALVES AND
FLOAT VALVES Swing check valves Secondary valves in a fire sprinkler system are not necessarily gate valves. AVK check valves are an excellent choice if you want to avoid reflux. A pump chamber for sprinkler systems often includes liquids that are not in contact with fire water and as such, they do…
-
BUTTERFLY VALVES
Butterfly valves with fixed liner AVK offers butterfly valves with fixed liner with three different connections; wafer, semi lug and double flanged. Grooved end butterfly valves The AVK butterfly valve with grooved ends is designed specifically for fire protection applications, and is UL listed and…
-
FIRE SAFETY APPROVALS
Most of AVK’s products in the fire protection range hold internationally recognised approvals such as UL, FM and VdS. UL (Underwriters Laboratory) has ever since 1900 worked to ensure fire safety in many fields. UL started originally in America but is today an internationally known institute…
-
Our hydrants and valves are being used in
• power plants • harbours • production facilities • hospitals • warehouses and elsewhere you need to construct a safe and secure solution for fire protection. Fire protection | 17
-
MARKET STANDARDS Inhouse R&D In our Development Department in Denmark, ideas and suggestions for new products are gathered, and existing products are updated continuously. We use FEA (Finite Element Analysis) to optimise the strength and geometry of our components and CFD (Computational Fluid…
-
FIRE PRODUCTS FOR OUTDOOR USE
Series 27/00 Dry barrel fire hydrant Modern style Bury depth 305-2438 mm 17,2 bar (250 PSI) Ductile iron UL/ULC listed, FM approved Series 27 Dry barrel monitor fire hydrant Bury depth 305-2438 mm 17,2 bar (250 PSI) Ductile iron UL/ULC listed, FM approved Inlet options: • DN100-150 flanged •…
-
FIRE PRODUCTS FOR INDOOR USE
Series 06/35 Flanged gate valve with position indicator DN50-400 PN10 or 16 Ductile iron VdS approved (DN50-200 only) Series 06/37 Grooved end gate valve with position indicator DN50-300 PN16 Ductile iron VdS approved (DN50-200 only) Series 145/50 Flanged gate valve with wrench nut DN65-200 17,2 bar…
-
FIRE PRODUCTS FOR INDOOR USE
Series 5190/00 Flanged swing check valve Spring loaded Grooved ends to AWWA C606 DN50-200 24,1 bar (300 PSI) UL/ULC listed, FM approved Series 5190/10 Swing check valve Spring loaded Grooved ends to AWWA C606 DN50-200 24,1 bar (350 PSI) UL/ULC listed, FM approved Options: • flange drilling to ANSI…
-
ACCESSORIES
22 | Fire protection Series 04 Extension spindle for gate valves Telescopic or fixed length Key adaptor #23-32 with spindle adaptor fitting to US type wrench nut DN40-400 Series 04/74 Surface box Reversible Ductile iron Series 04/15 T-key for below ground gate valves Series 04/24 Wrench nut for gate…
-
ACCESSORIES
Series 96/00 Limit switch IN62 with bracket for monitoring the position of NRS gate valves UL listed Series 96/00 Limit switch BI 2 for monitoring the position of NRS gate valves UL listed Series 96/00 Supervisory switch for monitoring the position of post indicator valves and series 145 OS&Y valves…
-
OPERATION OF
DRY BARREL FIRE HYDRANTS UL listed and FM approved The AVK dry barrel hydrant meets or exceeds the requirements of FM 1510 and UL 246. Hydrant, bury depth of 1.5 meters to bottom of pipe: • head loss = max. 0.069 bar per hose connection • flow = min. 946 l/min per hose connection Hydrant with pumper…
-
FLOW CHARACTERISTICS
Series 27 head loss - 4.5" Pumper nozzle 1,2 Head loss (bar) 1 0,8 0,6 0,4 0,2 27/00 - flow/pressure loss 1 x hose (2,5") = 212 m³/hour 1 x pumper (4") = 450 m³/hour 1 x pumper (4,5") = 470 m³/hour 0 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 1000GP LPM 825-BC 2900 LPM (750GPM) at 7 bar (100PSI)…
-
CORROSION PROTECTION
First all cast components are blast cleaned according to ISO 12944-4, SA 2½. The valve and hydrant bodies and bonnets and other components are fusion bonded epoxy coating in compliance with DIN 3476 part 1 and EN 14901 and GSK guidelines. The high quality epoxy coating is GSK approved and applied…
-
RUBBER TECHNOLOGY
Ability to regain shape: The high quality rubber used on the wedge has an excellent compression set also called memory (the ability to recover the original shape after being compressed). Even after many years of service where the wedge rubber has been compressed numerous times, the rubber will…
-
Bizonvej 1 Tel.: +45 8754 2100 Skovby sales@avk.dk 8464 Galten www.avkvalves.eu Denmark 2020-02-01 Copyright©AVK Group A/S 2020