WALL MOUNTED TYPE ROOM AIRCONDITIONER SPLIT SYSTEM, MULTIPLE TYPE Split system, Air cooled cooling only type ( ) SCM328CENF-L1 [SKM258CENF-L] SCM338CENF-L1 [SKM258CENF-L, SKM328CENF-L] 233
-
GENERAL INFORMATION 7.1.1 Specific features The “Mitsubishi Daiya” room air conditioner: SKM series are of split and wall mounted type and the unit consists of indoor unit and outdoor unit with refrigerant precharged in factory. The indoor unit is composed of room air cooling equipment with…
-
SELECTION DATA 7.2.1 Specifications (1) Indoor Unit Models SKM258CENF-L, 328CENF-L Model SKM258CENF-L Item Cooling capacity W SKM328CENF-L 2200/2200 Power source 2600/2600 1 Phase, 220/240V, 50Hz Noise level(4) dB (A) 38/39 Exterior dimensions 275 × 790 × 174 mm Height × Width × Depth 40/42 Color…
-
Outdoor Unit
Models SCM328CENF-L1, 338CENF-L1 Model SCM328CENF-L1 Item Cooling capacity W SCM338CENF-L1 2800/2800 Power source 2900/2900 1 Phase, 220/240V, 50Hz Inrush current Noise level A 16/17 16/17 dB (A) 44/44 44/44 Exterior dimensions 542 × 795 × 255 mm Height × Width × Depth Color Polar white Net weight…
-
(3) Operation data
Model SCM328CENF-L1 Cooling Indoor Unit Cooling capacity (kW) Running current (A) EER Total Cooling input (W) 25 2.2/2.2 2.2/2.2 730/770 3.4/3.3 3.01/2.86 25 + 25 1.4 + 1.4/1.4 + 1.4 2.8/2.8 770/800 3.6/3.4 3.64/3.50 Running current (A) EER Total Cooling input (W) Model SCM338CENF-L1 Cooling Indoor…
-
(1) Range of usage & limitations Inlet air temperature (a) Cooling operation 45 Outdoor air temp. ˚C.D.B 40 Applicable temp. range 35 JIS-Cooling Indoor air temp. ˚C W. B. 30 Note: The chart is result from the continuous operation under constant air temperature conditions. However, excludes the…
-
Exterior dimensions (1) Indoor unit Models SKM258CENF-L, 328CENF-L A 790 Unit: mm 3 174 Room temp. sensor 56 275 Piping hole right (left) 9 Terminal block 187.5 Piping for Gas * 62 18 (ø9.52) Piping for Liquid (ø6.35) 440 Drain hose 600 (ø16) Piping hole (ø65) Piping hole (ø65) VIEW A Note (1) Model…
-
Piping system
Model SCM328CENF-L1 Indoor B unit Indoor A unit Flare connecting ø9.52 (Gas) Outdoor unit Cooling cycle Service valve (Gas) Heat exchanger 7.2.4 Flare connecting Suction ø6.35 (Liquid) Flare connecting Model Compressor Thermistor Accumulator Heat exchanger Discharge Check joint Service valve…
-
Model
-
OUTLINE OF OPERATION CONTROL BY MICROCOMPUER 7.4.1 Table for operation control Functions High efficiency, low input rotary compressor Wireless remote control ON TIMER OFF TIMER Automatic fan control Micro computer control Comfortability, Economical efficiency, Operational simplicity Dry M. C. (Micro…
-
(b) Memory flap
• While the flap is operating if the AIRFLOW button is pushed once, Recommendable stopping angle of the flap it stops swinging at an angle. As this angle is memorized in the microcomputer, the flap will be automatically COOL DRY Horizontal blowing set to the angle when next operation is started. (c)…
-
(4) Operation control function by remote control switch
Remote control switch S Operation section OPERATION MODE select button Each time the button is pushed, the¡ indicator is switched over in turn. ON/OFF button Press for starting operation, press again for stopping. FAN SPEED button AIRFLOW button Each time the button is pushed, the¡ indicator is…
-
(a) Comfort timer settings
Temperature is checked beginning 1 hour before the set time, and the power is turned on before the timer setting as necessary to bring the temperature to the proper level by the set time. Operation mode Operating time (amount of time pervious to set time that operation begins) 60 mins. Room temp.…
-
(5) DRY operation
(a) Choose the appropriate operation block area by the difference between room temperature and thermostat setting temperature as shown below. • Operation block area D Block C Block –2 B Block 0 A Block +3 Room temp. – Setting temp.(deg) (b) Start up operation C.D Block A.B Block Compressor and…
-
Dew condensation prevention control for cooling operation This prevents dew condensation, in the indoor unit, from occurring. (a) Operating condition: when 52C is kept ON for 30 min, after the unit starts operation. (b) Operation content: forces the indoor fan to change from Speed 1 to Speed 2. (c)…
-
APPLICATION DATA SAFETY PRECAUTIONS ¡ Please read these “Safety Precautions” first then accurately execute the installation work. ¡ Though the precautionary points indicated herein are divided under two headings, WARNING and CAUTION , those points which are related to the strong possibility of an…
-
Remark per EMC Directive 89/336/EEC
For to prevent flicker impressions during the start of the compressor (technical process) following installation conditions do apply. 1. The power connection for the air conditioner has to be done at the main power distribution. This distribution has to be of an low impedance. Normally the required…
-
(3) Limitations for one way piping length and vertical height difference
¡ SCM328CENF-L1 Outdoor unit Indoor unit r1 +r2 = 15m max 5m max Indoor unit Indoor unit r1 r1 Outdoor unit r2 r2 height 5m max Outdoor unit r1 height 5m max Indoor unit height 5m max r2 Indoor unit Indoor unit ¡ SCM338CENF-L1 Indoor unit Indoor unit Auto selector kit r2 Outdoor unit r3 r1 = 3m max…
-
Drilling of holes and fixture sleeve (Option parts)
(a) (b) Adjusting sleeve length Drill a hole with ø65 whole core drill Cut off the sleeve collar in case of drawing piping out to rear. Indoor side Cut off the sleeve coolar that can be seen from beneath the unit. Outdoor side Wall thickness + 1.5 cm Note (1) Drill a hall with incline of 5 degree…
-
[When the pipe is extended to left and taken out from the rear center]
(Drain pipe relocation procedure) 1. Remove the drain pipe. 2. Remove the drain cap. 3. Insert the drain cap. 4. Connect the drain pipe. ¡ Loosen the spring clamp to remove. ¡ Remove by hand or use cutting pliers, etc. ¡ Securely insert the drain cap removed in the step 2. Note: If it is inserted…
-
◆ Installation directions auto selector kit (only for SCM338 model)
(1) Selection of installation location (Install at location that meets the following conditions after getting the approval from the customer). (a) Do not install the auto selector kit indoors. (b) A location where rain and snow will not directly strike the kit. (c) A location where servicing space…
-
(3) Mounting of interconnecting wires (Field wiring)
(a) Use cable for interconnection wiring to avoid loosening of the wires. CENELEC code for cables required field cables. H05 RNR3AG1.5 (b) Connect the connection wire securely to the terminal block. (c) In wiring, make sure that the wire terminal numbers are matched to the wire terminal numbers of…
-
Refrigerant piping (1) Preparation Keep the openings of the pipes covered with tapes etc. to prevent dust, sand, etc. from entering them. Outdoor unit side Indoor unit side Press Press (Do not turn) Remove Remove ¡ Remove the flared nuts. (on both liquid and gas sides) Dimension A Liquid side…
-
(5) Insulation of connecting portion
1) Cover the connecting portion of the refrigerant piping with the pipe cover and seal them. If neglecting to do so, moisture occurs on the piping and water will drip out. Cover the coupling with insulator and then cover it with tape Place the slit upward Viny tape Insulation Refrigerant piping…
-
(1) Precautions for wireless remote controller installation and operation Wireless remote controller covers the following distances: (a) When operating facing the air conditioner: 6 m or le 6 m or less s or less or less ss Wireless remote controller or les Notes (1) The remote controller is…
-
MAINTENANCE DATA 7.6.1 Trouble shooting (1) Trouble shooting to be performed prior to exchanging PCB, (Printed circuit board) [Common to all models] All the models described in this chapter are controlled by a microcomputer. When providing maintenance service to customers it is necessary to…
-
Indication of Self Diagnosis (Indoor unit)
TIMER lamp is lights continuously Connect of Defect Place of defect RUN lamp is flashing. (1 Time/8 sec.) Abnormality of heat exchanger thermistor. ¡ Disconnection of heat exchanger thermistor. RUN lamp is flashing. (2 Time/8 sec.) Abnormality of room temperature thermistor. ¡ Disconnection of room…
-
(4) Trouble shooting chart for the room temperature thermistor (Th1), heat exchanger thermistor (Th2) Indoor Unit Unit Sensor Operation Room temperature thermistor(1) (Th1) except for “continuous” thermal setting Cooling Function Short circuit Continuous Cooling operation • Cannot be turned ON/OFF…
-
Servicing (1) Evacuation The evacuation is an procedure to purge impurities……noncondensable gas, air, moisture from the refrigerant equipment by using a vacuum pump. Since the refrigerant R22 is very insoluble in water, even a small amount of moisture left in the refrigerant equipment will freeze…