DEH UM IDIF IER
MODEL: MDDP-30DEN7-QA3 REFRIGERANT: R290/0.1kg MODEL: MDDP-50DEN7-QA3 REFRIGERANT: R290/0.145kg The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details. Any updates to the manual will be uploaded to…
-
To prevent injury to the user or other people and property damage, the following instructions
must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications. WARNING This symbol indicates the possibility of death or serious injury. CAUTION This symbol indicates the possibility of injury or damage to…
-
Contact the authorised installer for installation of this unit
If the air conditioner is knocked over during use, turn off the unit and unplug it from the main power supply immediately. Visually inspect the unit to ensure there is no damage. If you suspect the unit has been damaged, contact a technician or customer service for assistance. In a thunderstorm, the…
-
! WARNINGS (for using R290/R32 refrigerant only)
1.Transport of equipment containing flammable refrigerants See transport regulations 2.Marking of equipment using signs See local regulations 3.Disposal of equipment using flammable refrigerants See national regulations. 4.Storage of equipment/appliances The storage of equipment should be in…
-
preventing the ingress of flammable atmospheres. Replacement parts shall be in accordance
with the manufacturer's specifications. NOTE: The use of silicon sealant may inhibit the effectiveness of some types of leak detection equipment. Intrinsically safe components do not have to be isolated prior to working on them. 8.Repair to intrinsically safe components Do not apply any permanent…
-
CONTROL PADS ON THE DEHUMIDIFIER
the equipment are removed from site promptly and all isolation valves on the equipment are NOTE: The control panel of the unit you purchased may be slightly different according to the models. High fan indicator light WiFi indicator Continuous Bucket full Auto defrost operation light operation on…
-
CONTROL PADS ON THE DEHUMIDIFIER
CONTROL PADS ON THE DEHUMIDIFIER Identification of par ts 9 Display Shows the set % humidity level from 35% to 85% or auto start/stop time (0~24) while setting, then shows the actual ( 5% accuracy) room % humidity level in a range of 30% RH(Relative Humidity) to 90%RH(Relative Humidity). Error Codes…
-
OPERATING THE UNIT
IDENTIFICATION OF PARTS Positioning the unit Removing the collected water A dehumidifier operating in a basement will have little or no effect in drying an adjacent enclosed storage area, such as a closet, unless there is adequate circulation of air in and out of the area. Do not use outdoors. 40cm…
-
CARE AND MAINTENANCE
OPERATING THE UNIT Removing the collected water Removing the collected water 2. Continuous draining Water can be automatically emptied into a floor drain by attaching the unit with a water hose (Id 5/16 , not included) with a female threaded end (ID:M=1 , not included) NOTE: On some models, the…
-
CARE AND MAINTENANCE
TROUBLESHOOTING TIPS Care and cleaning of the dehumidifier Before calling for service, review the chart below first yourself. Turn the dehumidifier off and remove the plug from the wall outlet before cleaning. 1. Clean the Grille and Case Use water and a mild detergent. Do not use bleach or…