1. Features
1.1 High static pressure allows flexible duct design 1.1.1 External static pressure of Indoor Unit can be up to 250 Pa, which allows extensive duct work for flexible applications. So the cool air can be delivered to each corner even in a super-high ceiling. 1.1.2 With 420mm (71~160 model) thickness…
-
Three speeds fan motor (for 400~560 model)
1.4 Two external static pressure settings for added flexibility Just exchange the wiring connection of ‘MH’ and ‘Me’. P2 and P3 as the right side diagram.*(for 71~160 model) 1.5 Convenient installation 1.5.1 The EXV is fixed inside the indoor unit ((for 71~160 model), no need extra connection. 1.5.2…
-
2. Specifications
Model MDV-D71T1/N1-B Power supply V- Ph-Hz MDV-D80T1/N1-B MDV-D90T1/N1-B 220-240V~, 1Ph, 50Hz Capacity kW 7.1 8.0 9.0 Input W Rated current A 1.1 1.1 1.8 Capacity kW 8.0 9.0 10.0 Input W Rated current A 1.1 1.1 1.8 Max. input consumption W Max. current A 1.23 1.23 1.87 YDK100-4X-2 YDK100-4X-2…
-
Model
MDV-D112T1/N1-B Power supply V- Ph-Hz MDV-D140T1/N1-B MDV-D160T1/N1-B 220-240V~, 1Ph, 50Hz Capacity kW 11.2 14 16 Input W Rated current A 2.3 2.7 3.6 Capacity kW 12.5 16 17 Input W Rated current A 2.3 2.7 3.6 Max. input consumption W Max. current A 2.3 2.85 4.77 YSK200-4F-1 YSK300-4C-1 YSK400-4C-2…
-
Model
MDV-D200T1/N1-B Power supply V- Ph-Hz MDV-D250T1/N1-B MDV-D280T1/N1-B 220-240V~, 1Ph, 50Hz Capacity kW 20.0 25.0 28.0 Input W 1516 1516 1516 Rated current A 6.6 6.6 6.6 Capacity kW 22.5 26.0 31.5 Input W 1516 1516 1516 Rated current A 6.6 6.6 6.6 Max. input consumption W 1978 1978 1978 Max. current…
-
Model
MDV-D400T1/N1 Power supply MDV-D450T1/N1 V- Ph-Hz MDV-D560T1/N1 220-240V~, 1Ph, 50Hz Capacity kW 40.0 45.0 56.0 Input W 2700 2700 3400 Rated current A 12.5 12.5 15.5 Capacity kW 45 50.0 63.0 Input W 2700 2700 3400 Rated current A 12.5 12.5 15.5 Max. input consumption W 2700 2700 3400 Max. current A…
-
3. Dimensions
MDV-D71T1/N1-B MDV-D80T1/N1-B MDV-D90T1/N1-B MDV-D112T1/N1-B Front view, top view and rear view: PLASTIC COVER ELECTRICAL CONTROL BOX AIR INTAKE 4-12*25 OBLONG SUSPENTION BOLT HOLES AIR OUTLET DUCT FLANGE 155 4-Φ5HOLES FOR AIR INTAKE DUCT CONNECTION 339 AIR OUTLET 65 Indoor Unit
-
Side view
Left side REFRIGERANT-PIPE FLANED CONNECTION Φ9.52(3/8) 43 123 REFRIGERANT-PIPE FLANED CONNECTION Φ16(5/8) 189 CONNECTING POINT OF DRAIN PIPE 75 61 SAFETY DRAIN CONNECTING PIPE Right side 123 189 Indoor Unit
-
Front view, top view and rear view: Indoor Unit 143
-
Side view
Left side Right side 144 Indoor Unit
-
Front view, top view and rear view: 1121 Entrances and exits for communication lines of indoor and outdoor Air outlet 4-12*25 oblong suspention bolt holes Electrical parts box Air outlet duct flange 810 4-Φ10 hanging screw (configure on spot) Refrigerant-pipe flared connectionΦ9.52(3/8) 66 Air…
-
Key points about the 200, 250, 280,400,450,560 model installation
There’re two sets of EXV boxes in 200,250 & 280 model and four sets of EXV boxes in 400,450 & 560 model , as well two groups of pipes (Gas/Liquid), it’s necessary to connect the two gas pipes together with the attached branch header BY101N1, as well the liquid pipes. The branch header (1 set)…
-
4. Service Spaces
Ensure the needed spaces for installation and maintenance. The ceiling is horizontal, and its structure can endure the weight of the indoor unit. The outlet and the inlet are not impeded, and the influence of external air is the least. The air flow can reach throughout the room. The…
-
5. Piping Diagrams
-
150 Indoor Unit
-
6. Wiring Diagrams
-
152 Indoor Unit
-
Indoor Unit 153
-
154 Indoor Unit
-
7. Fan Performance
-
P(Pa) P(Pa) MDV-D160T1/N1-B 16KW 20/25/28KW 260 260 High speed High speed Medium speed 200 Medium speed Low speed Low speed 0 1000 1400 1800 2200 2600 3000 3400 3800 1790 3 2000 2500 3000 3500 4000 4500 5000 5500 6000 2890 Q(m /h) Q(m 3/h) MDV-D400(450)T1/N1 MDV-D560/T1/N1 300 P(Pa) P(Pa) 40KW/h…
-
8. Capacity Tables
-
16.0 20.0 158 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 42.0 44.0 46.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 42.0 44.0 46.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 42.0 44.0 46.0 10.0…
-
28.0 40.0 Indoor Unit 27.0 29.0 31.0 33.0 35.0 37.0 39.0 42.0 44.0 46.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 42.0 44.0 46.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 42.0 44.0 46.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0…
-
56.0 160 43.0 45.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 42.0 44.0 46.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 42.0 44.0 46.0 27.6 27.6 31.1 31.1 31.1 31.1 31.1 31.1 31.1 31.1 31.1 31.1 31.1 31.1 31.1 31.1 31.1 31.1…
-
8.2 Heating
-
16.0 20.0 162 -17 -15 -13.00 -11.00 -10.00 -9.10 -7.60 -5.60 -3.70 -0.70 2.20 4.10 6.00 7.90 9.80 11.80 13.70 -20 -19 -17 -15 -13.00 -11.00 -10.00 -9.10 -7.60 -5.60 -3.70 -0.70 2.20 4.10 6.00 7.90 9.80 11.80 13.70 -20 -19 -17 -15 -13.00 -11.00 -10.00 -9.10 -7.60 -5.60 -3.70 -0.70 2.20 4.10 6.00 7.90…
-
28.0 40.0 Indoor Unit -3.70 -0.70 2.20 4.10 6.00 7.90 9.80 11.80 13.70 -20 -19 -17 -15 -13.00 -11.00 -10.00 -9.10 -7.60 -5.60 -3.70 -0.70 2.20 4.10 6.00 7.90 9.80 11.80 13.70 -20 -19 -17 -15 -13.00 -11.00 -10.00 -9.10 -7.60 -5.60 -3.70 -0.70 2.20 4.10 6.00 7.90 9.80 11.80 13.70 -20 -19 -17 -15…
-
56.0 164 13.70 -20 -19 -17 -15 -13.00 -11.00 -10.00 -9.10 -7.60 -5.60 -3.70 -0.70 2.20 4.10 6.00 7.90 9.80 11.80 13.70 -20 -19 -17 -15 -13.00 -11.00 -10.00 -9.10 -7.60 -5.60 -3.70 -0.70 2.20 4.10 6.00 7.90 9.80 11.80 13.70 MCAC-VTSM-2013-10 15 -19.8 -18.8 -16.7 -14.7 -12.6 -10.5 -9.5 -8.5 -7 -5 -3…
-
9. Electrical Characteristics
-
10. Sound Levels
-
11. Accessories
11.1 Standard accessories Name Installation manual Pipe insulation material Qty. Shape Usage 1 / / 71~160 2 200 and up 4 Adhesive tape for seal (except 400,450,560 model) Heat insulation 2 To connect drain pipe 2 1 liquid and 1 gas branch To connect the two circuits of indoor unit as one system. 1…
Схемы, таблицы и рисунки — в просмотре документа выше. Клик по номеру страницы открывает её в просмотре.