Air Handling Units
Geniox Catalogue
-
This catalogue presents a technical description
of the Geniox air handling unit, its components and accessories. Geniox is designed as a modular air handling unit. Each function is placed into an air handling unit casing consisting of one or more modules. It is available in 12 sizes with airflows from 750 to 48,000 m3/h (0.2-13.3 m3/s). Geniox…
-
Contents
Comfort ventilation by Systemair . . . . . . . . . . . . . . . . . . . . . . . . 4 Geniox . . . . . . . . . . . . . . . . . . . . . . . . 6 Geniox, innovative solutions . . . . . . . . . . . . . . . . . . . . . . . . 8 Geniox functions . . . . . . . . . . . . . . . . . . . . . . . . 10 Systemair…
-
Comfort ventilation
by Systemair Comfort ventilation describes the ventilation systems most often used in hospitals, hotels, schools, and offices. The purpose of this ventilation system is to create a healthy and comfortable indoor climate. Geniox is designed in flexible modules. This gives you the freedom to choose…
-
accounts for 40% of a building’s energy consumption. That means there is a significant potential for improvement. Geniox aims to exploit that potential and reduce the percentage. Geniox air handling units feature the most energy efficient motors. The unit employs the latest advances in energy…
-
Geniox
AHU No 17.07.012 Range: Geniox-1 Geniox is designed as a modular air handling unit. Each function is placed into an air handling unit casing consisting of one or more modules. The modular functions can be configured for many different applications to make up the heart of any ventilation system. •…
-
Geniox, innovative solutions
Casing • Thermal bridging class TB2. • Thermal insulation class T2. • Deflection class D1. • Air leakage class L1. Official model box EN 1886 results. Panels. Elimination of thermal bridges. Separation between inner sheet and outer sheet (0,8 mm) with 60 mm insulating mineral wool. Density: 60…
-
Service and maintenance. All doors
provide easy access for cleaning and service. Transportation. Casing design and standard packaging allows for easy transportation. Roof unit. Geniox is available as roof unit, designed for outdoor installation. In this version the unit is assembled on a base frame. The roof unit can be delivered…
-
Geniox functions
The plug fan has the impeller fitted with air foiled blades to obtain the highest possible efficiency. The fan is a single inlet, free-blowing fan where the unit casing acts as fan housing. The plug fan has a static efficiency of up to 75%. The plug fan can be supplied with EC motor (IE5), PM motor…
-
The heat pump is an integrated reversible heat
pump system built into a unit section. The system consists of a reversible heat pump and a rotary heat exchanger that enables both heating and cooling. The unit is equipped with scroll compressors, and cooling/heating capacity is stepless variable in the range 5-100%. The heat pump is based on…
-
30 Jan 10:00
Running mode: Normal operation Open SFP: 1.87 kW/m3/s 2880 m³/h 0.3 °C 76 Pa 162 Pa 22.1 °C 37 % -5.8 °C 82 % η -5.1 °C 7200 m³/h 14 Pa 77 % 100 % 32 % Extra sensor 1: 58.3 °C 810 ppm 31 %RH 22.3 °C 100% 17.1 °C 22.1 °C 38 % ON 18.8 °C 0% OFF 180 Pa 2875 m³/h Extra sensor 2: 18.2 °C Extra sensor 3…
-
Download SystemairCAD
from Systemair’s website. Configure Geniox with SystemairCAD SystemairCAD is a user-friendly design program which ensures an optimal dimensioning of the air handling unit’s functions. When the unit design is finished, SystemairCAD makes a technical calculation and automatically generates a complete…
-
Quick selection of Geniox
Unit size Rotary heat exchanger Unit Width 1082 1182 1282 1482 1682 1882 2082 2282 2482 2782 2982 3182 Height* 1082 1182 1282 1482 1682 1882 2082 2282 2482 2764 2964 3164 Length 2282 2282 2282 2282 2282 2282 2382 2464 2464 2946 3146 3146 The above dimensions are a guideline only. Accurate values and…
-
ErP
Directives and certifications Eurovent certification Geniox air handling units are Eurovent certified. This ensures the conformity between the calculated performance in SystemairCAD design program, and the measured performance at independent test laboratories. Certificate 17.07.012. Eurovent energy…
-
Standards
The Geniox design is based on the demands in the following CEN and ISO standards: EN 1751:2014 Aerodynamic testing of dampers and valves. EN ISO 3741:2010 Determination of sound power level in reverberation rooms. EN 305:1997 Heat exchangers. Definition and test procedures. EN 1886:2008 Air handling…
-
Geniox casing
Air handling unit casing The casing protects the inside functions and is very effective for thermal and sound insulation. Thermal insulation Class T2. Sound and thermal insulating mineral wool, which is completely encapsulated between two steel sheets. Thickness: 60 mm. Density: 60 kg/m3. Thermal…
-
Filter by-pass leakage
Class F9 according to EN 1886. Free area in front of and above the unit When positioning the unit, we recommend that an area in front of the inspection side with the same width as the unit is kept free for service and inspection and also for replacement of fans, heat exchanger, and coils, if needed.…
-
Roof unit
The Geniox air handling unit is available as a roof unit for outdoor installation. Function For the outdoor installation the unit is assembled on a base frame and features a roof construction which together with the double sealing of the panels provides protection against the effects of the weather.…
-
Pre-painted unit
The Geniox air handling unit is available with black or light grey pre-painted steel sheets. Function The black variant of Geniox is especially suitable for outdoor units when a good blending in with a dark facade and dark roof is required. The light grey variant is well-suited for both indoor and…
-
EC Bluefin plug fan
PM/AC plug fan. Plug fan The plug fan is built into an acoustically insulated air handling unit. 22 Construction Single inlet plug fan with open outlet into the air handling unit. The fan impeller is fitted directly to the motor. Static efficiency up to 75%. To optimise the plug fan efficiency in…
-
Balancing
-
Rotary heat exchanger
Regenerative heat exchanger with high efficiency. Versions The rotary heat exchanger is available in 4 versions: • A: Low pressure drop = standard efficiency • B: Normal pressure drop = normal efficiency • C: Medium high pressure drop = medium high efficiency • D: High pressure drop = high…
-
condensation and sorption hybrid heat
exchanger 0-10 V corresponds to 0-12 rpm, and for sorption heat exchanger to 0-20 rpm. The lower half of the exchanger and the hub of the rotor are assembled into the lower half of the AHU casing. All other parts of the heat exchanger are supplied for local assembly. Direction variants 1 Alarm…
-
Cross flow heat exchanger
Counter flow heat exchanger Plate heat exchanger Recuperative plate heat exchanger with high efficiency. Application The plate heat exchanger is used where there are special requirements for separation of the two airflows, e.g. in order to avoid transfer of odours to the supply air. The heat…
-
Cross flow heat exchanger (x)
Counter flow heat exchanger (c) Air direction variants Extract air, diagonal upstream * Air direction variants Extract air, diagonal downstream Cross flow and counter flow heat exchanger Cross flow heat exchanger Outdoor air Extract air Exhaust air Supply air Exhaust air Supply air Outdoor air…
-
Run-around coil heat exchangers
Heat exchanger system using two water coils to transfer via pipe system the cold/heat between extract and supply units. Application The run-around coil heat exchangers are used where it is a requirement that the two airflows must be kept completely separated, or where they are at a distance from…
-
Heating coil
Air heater Heating media W – Hot water. Max. temperature 100 °C, max. working pressure 10 Bar. Available for temperatures up to 130 °C. Construction Water coils and condensation coils are made of copper tubing and aluminum fins. Coils for electrical heating consist of stainless steel tube heating…
-
Cooling coil
Air cooler Cooling media W – Cold water. Max. working pressure 10 Bar. D – Evaporation. Max. working pressure depending on the type of refrigerant. Variants Standard – Cooling coil completely built into the unit. MAX – Cooling coil which is wider than the unit, i.e. full-size coil to increase…
-
Change-over coil
Heating of air with hot water/glycol. Cooling of air with cold water/glycol. Heating/cooling media W – Hot/cold water. Max. working pressure 10 Bar. Variants Standard – Heating/cooling coil completely built into the unit. MAX – Heating/cooling coil which is wider than the unit, i.e. full-size coil…
-
Integrated reversible heat pump
The integrated heat pump system is built into a unit section. The system consists of a reversible heat pump and a rotary heat exchanger that enables both heating and cooling. The heat pump system can be supplied for Geniox 10 to 24. Ready for operation at delivery The integrated heat pump system is…
-
Cooling and heating capacity, example with Geniox 18 with heat pump
-
height. The humidifier can be stepcontrolled as illustrated on the next
page. Air humidifier Humidifier for adiabatic cooling and humidification. Function The function is based on the natural process that water evaporates when air passes a wet surface. By uptake of water vapor in the air, the temperature will decrease due to the fact that heat for the evaporation comes…
-
A E D G C B A. Process air B. Humidified air C. Water supply D. Overflow E. Constant bleed off F. Drainage G. Water outlet to drain 1. Humidification element 2. Droplet eliminator (optional) 3. Water recirculations pump 4. Bleed off regulation valve 5. Irrigation regulation valves 6. Float valve 7.…
-
Panel filter
-
Filter frame
The filter cells are supplied with 25 mm standard plastic frame. Therefore, used filters can be disposed of in their entirety by combustion. Sealing Rubber sealing strips are fixed to the filter cells. Air tightness according to EN 1886:2008. Fitting the filter cells The cells are sealed with the…
-
Metal filter
-
Carbon filter
Supply air, recirculation, or exhaust filter. Filtermaterial • Carbon type CEX003 in a cylindrical cartridge. • Length 450 mm. Max. air flow 1,120 m3/h, 135 Pa. • The air flow and pressure are applicable for 16 cylinders on a 610 x 610 mm bottom plate. Filter cartridge Cartridge frame in solid cast…
-
Damper
The dampers can be used as shut-off dampers for intake, extract, exhaust, and outdoor air. The dampers can also be used for mixing and recirculation. Air tightness classification • Class 4 (leakage through a closed damper). • Class C (casing leakage). According to EN 1751:2014. Damper blades…
-
Dampers external on unit – Duct connection sizes, 20 mm flange connection Damper type W 1150 1350 1550 1750 1950 2150 - - - H 1000 1100 - - - W 1150 1350 1550 1750 1950 2150 - - - H - - - W 800 900 1000 1200 1400 1600 1800 - - - - - H - - - - - W 1000 1100 1200 1300 1400 H 1000 1100 1200 1300 1400…
-
Sound attenuator
The sound attenuator is used to reduce the sound power level from the air handling unit to the duct system. Variants 1. Baffles with standard lining. Each baffle is enclosed in an Aluzinc frame. Construction The sound attenuator is an absorption attenuator with baffles made of rockwool. The baffles…
-
Inspection section
The inspection section is used where the option of service, inspection, or measuring is required, before or after an air handling function. Construction The inspection section consists of an empty unit casing with an inspection door. Accessories • Inspection window fitted into the inspection door. •…
-
Empty section
Used in units where space is required to fit a component, e.g. a temperature sensor, or to have the option of applying an extra air handling function at a later date. Construction The empty section consists of an empty unit casing, where the side panels are assembled with screws. 44 systemair…
-
Outdoor air section
The outdoor air section is used for air intake and outlet in roof units. Function The outdoor air section has air intake through the end of the unit, and outlet of exhaust air through the back wall of the unit. Type 1 Construction The outdoor air section consists of an air handling unit casing with…
-
Supporting legs
Units in sizes Geniox 10-18 for indoor installation can be supplied with supporting legs. Construction Supporting legs are made of Magnelis ZM310. Pre-painting in RAL 7024 of the supporting legs is an option. They are 118 mm high, and have feet which are adjustable from 30-55 mm. 118 118 Ø50 30-55…
-
Standard base frame
in a pre-painted version Base frame with high legs Standard base frame and base frame with high legs Standard base frame Units for indoor installation can be supplied with base frame in height 118 mm with ø 50 mm holes or 218 mm with ø 80 mm holes. The base frame has feet which are adjustable from…
-
Base frame with forklift holes
Geniox air handling units for indoor installation In order to save time on the building site it is an option to choose a unit delivered on a base frame with forklift holes. This is an option for Geniox sizes 10-31 (not applicable for units with heat pumps). 48 systemair Construction The height of…
-
Assembly brackets
The assembly bracket is designed to ensure an airtight connection between the casing sections. Assembly brackets For air handling units divided in sections, the assembly brackets are mounted externally. Screws and nuts are delivered separately. For air handling units mounted on a base frame and…
-
Duct connection part
The connection part is used when connecting duct work to the Geniox air handling unit, either as rigid connection or as rigid and flexible connection. Variants End of unit. Top half face. Top full face. Back of unit. Dimensions Unit size End of unit Top half face Top full face Back of unit 50…
-
Duct connection part
Rigid 20 Rigid Rigid connection part for connecting to 20 mm LS profile for C-rail, and for 20 mm EP/LSM profile with holes in the corners. Flexible 20 Flexible connection part for connecting to 20 mm LS profile for C-rail. For mounting in continuation of rigid connection part. 5 5 Rigid connection…
-